FMB209 General description

From Wiki Knowledge Base | Teltonika GPS
FMB209 Manual > FMB209 General description

FMB209 is a tracking terminal with GNSS and GSM connectivity, which is able to collect device coordinates and transfer them via GSM network to a server. This device is perfectly suitable for applications, which require the location acquirement of remote objects.

Package contents

The FMB209 device is supplied to the customer in a cardboard box containing all the equipment that is necessary for operation. The package contains:

  • FMB209 device with case and wires;
  • USB cable (optional);
  • Integrated Li-ion battery 3.75V, 800mAh for FMB209 device;

Basic characteristics

GSM / GPRS / GNSS features:

  • Teltonika TM2500 quad band module (GSM 850 / 900 / 1800 / 1900 MHz);
  • GPRS Multi-Slot class 12 (Up to 85,6 kbps);
  • SMS (text, data);
  • Integrated GNSS receiver;
  • Up to -162 dBm GNSS receiver sensitivity.
  • GNSS Module - AG3335MN;

Hardware features:

  • 128 MB internal Flash memory (422 400 Records);
  • Built-in movement sensor;
  • Integrated Li-ion battery 3.75V, 800mAh for FMB209 device;
  • Internal High Gain GSM antenna;
  • Internal High Gain GNSS antenna;

The Interface features:

  • Power supply: 10 ... 30V;
  • USB port;
  • 2 digital inputs;
  • 2 Analog/Digital inputs;
  • 2 open collector digital outputs (connecting external relays, LED’s, buzzers, Panic buttons, etc.);
  • RS232 connection
  • 2 LED’s indicating device status.

Special features:

  • High Quality track even in high density urban canyon;
  • Ready for harsh environment;
  • Any element event triggers (external sensor, input, speed, temperature, etc.);
  • Highly configurable data acquisition and sending;
  • Multiple Geo-fence areas;
  • Sleep mode;
  • Deep sleep mode;
  • Configurable scenarios available;
  • Real-time process monitoring;
  • Authorized number list for remote access;
  • Firmware update over GPRS or USB port;
  • Configuration update over GPRS, SMS or USB port;
  • TCP/IP or UDP/IP protocol support;
  • >500000 record storing;
  • Overvoltage protection.


Description Voltage Duration
Normal operation +10 ... 30 V Unlimited
Protection turns on, device turns off 34 V Unlimited
Maximum voltage < 70 V Unlimited
Maximum voltage impulse 120 V 10 ms


Technical features


Part name Physical specification
Navigation indication LED
Modem indication LED
USB Mini USB socket
GNSS Internal GNSS antenna
GSM Internal GSM antenna


Technical details
Power supply 10 ... 30V DC
1.5 W max. device consumption
Energy consumption at 12 V:
GPRS: average 59.13 mA r.m.s;
Nominal: average 26.21 mA;
GPS Sleep: average 10.55 mA;
Online Sleep: average error mA;
Deep Sleep: average 7.02 mA;
Ultra Sleep: average 4.55 mA
FMB20X Battery charge current max. 207 mA
Operating temperature (without battery) -40..+85 °C
Storage temperature (without battery) -40..+85 °C
Storage relative humidity 5..95% (no condensation)
Device + case + battery weight

With 400 mAh bat. - 170 g
With 1800 mAh bat. - 210 g


Dimension drawing:

FMB202 view dims.jpg

Technical information about internal battery

Internal back-up battery Battery voltage (V) Nominal capacity (mAh) Power (Wh) Charging temperature (°C)
Li-ion rechargeable battery 3.75~3.90 800 2.96 0 - 50

Batteries are covered by 6 month warranty support.

Bw nb.png CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Bw disposal.png Battery should not be disposed of into general household waste.
Bring damaged or worn-out batteries to your local recycling center or dispose them into a battery recycle bin commonly found in supermarkets.

Electrical characteristics


Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage
(Recommended Operating Conditions)
10 30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF) 120 µA
Drain current
(Digital Output ON, Recommended Operating Conditions)
0.1 0.5 A
Static Drain-Source resistance (Digital Output ON) 120
Digital Input:
Input resistance (DIN1) 59.9
Input resistance (DIN2, DIN3) 67.5
Input voltage
(Recommended Operating Conditions)
0 60 V
Input Voltage threshold (DIN1) 7.5 7.7 8 V
Input Voltage threshold (DIN2, DIN3) 2.5 2.7 3 V
Analog Input:
Input voltage
(Recommended Operating Conditions), Range 1
0 10 V
Input resistance, Range 1 120
Input voltage
(Recommended Operating Conditions), Range 2
0 30 V
Input resistance, Range 2 146.7
Output inner resistance 450 600
Output current (Uout > 3.0 V) 75 mA
Short circuit current (Uout = 0) 75 mA


Alert.png
Analog Input error margin can increase if temperature varies.