FMB641 Product Change Notifications
Product change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc. This page stores information regarding changes to the FMB641 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).
2023.07.18: GNSS antenna changes
We would like to inform you about the GNSS antenna changes update for FMB641 starting date changed to August 2023.
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMB641 | FMB641*******order codes | No changes |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change. New antennas were used in mass production before | |
Suggested implementation plan | No implementation plan needed |
2023.06.02: Base firmware update
We would like to inform you about the base firmware update for FMB641 starting from July 02 2023. New production firmware version will be 02.02.17.Rev.04.
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB641_firmware_errata | |
Old version: FMB641 02.02.16.Rev.03 |
New version: FMB641 02.02.17.Rev.04 | |
Change reasons | FMB641 base firmware version update | |
Product release date | July 2023. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMB641 | FMB641*******order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above |
2023.04.12: SIM usage recommendation update
We would like to inform you about the SIM usage recommendation change - due to SIM card market tendencies (Standard size SIM cards being made to split to 3 parts) FMC640 First Start
Recommendation description | ||
---|---|---|
Recommendation reason | Due to SIM card market tendencies (Standard size SIM cards being made to split to 3 parts) | |
Detailed description | New paragraph about SIM usage is added to product First Start description. Previously SIM insertion recommendation was only described in schematics - SIM1 shown in lower slot, SIM2 in upper slot.
To avoid such risk: |
Change impact | ||
---|---|---|
Risk assessment | Recommendation updated to mitigate risk. | |
Suggested implementation plan | If you used one SIM card and it's placed in SIM1 slot (lower) - no implementation plan needed. If you used 2 SIM cards - SIM1 in lower slot, SIM2 in upper slot - no implementation plan needed. Additionally: If possible - ask operator for Standard SIM card with solid construction (not pre-cut to 3 parts) |
2023.02.27: GNSS antenna changes
We would like to inform you about the GNSS antenna changes update for FMB641 starting date changed to March 2023.
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMB641 | FMB641*******order codes | No changes |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change. New antennas were used in mass production before | |
Suggested implementation plan | No implementation plan needed |
2023.02.24: Base firmware update
We would like to inform you about the base firmware update for FMB641 starting from February 24 2023. New production firmware version will be 02.02.16.Rev.03.
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB641_firmware_errata | |
Old version: FMB641 02.02.15.Rev.06 |
New version: FMB641 02.02.16.Rev.03 | |
Change reasons | FMB641 base firmware version update | |
Product release date | March 2023. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMB641 | FMB641*******order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. Firmware 02.02.16.rev.03 new factory firmware has configuration stability improvements especially for clients which is using J1708 functionality. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above |
2022.10.07: Base firmware update
We would like to inform you about the base firmware update for FMB641 starting from October 07 2022. New production firmware version will be 02.02.15.Rev.06.
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB641_firmware_errata | |
Old version: FMB641 02.02.09.Rev.00 |
New version: FMB641 02.02.15.Rev.06 | |
Change reasons | FMB641 base firmware version update | |
Product release date | October 2022. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMB641 | FMB641*******order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above |
2022.05.24: GNSS antenna changes
We would like to inform you about the GNSS antenna changes for FMB641 starting September 2022.
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMB641 | FMB641*******order codes | No changes |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change | |
Suggested implementation plan | No implementation plan needed |
2022.04.29: Base firmware update
We would like to inform you about the base firmware update for FMB641 starting from April 29 2022. New production firmware version will be 02.02.09.Rev.00.
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB641_firmware_errata | |
Old version: FMB641 02.02.04.Rev.00 |
New version: FMB641 02.02.09.Rev.00 | |
Change reasons | FMB641 base firmware version update | |
Product release date | May 2022. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMB641 | FMB641*******order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above |