FMB900 is a tracking terminal with GNSS and GSM connectivity, which is able to collect device coordinates and transfer them via GSM network to a server. This device is perfectly suitable for applications, which require the location acquirement of remote objects.
Package contents
The FMB900 device is supplied to the customer in a cardboard box containing all the equipment that is necessary for operation. The package contains:
Already implemented FMB900 device into case;
Top and bottom device cover parts;
and output power supply cable with a 1x5 connection pins, which is already installed into device.
1 open collector digital output (connecting external relays, LED, buzzers etc);
2 LEDs indicating device status.
Special features:
Fast position fix (Outdoor areas);
High Quality track even in high density urban canyon;
Ultra small case;
Ready for harsh environment;
Easy to mount in limited access areas;
Firmly fasten;
2 LED status indication;
Real time tracking;
Smart data acquisition based on:
Time;
Speed;
Angle;
Distance;
Ignition or any other I/O event;
Sending acquired data via GPRS;
GPRS and SMS I/O events;
Virtual odometer;
Jamming detection;
Configurable using Secured SMS Commands;
Color ribbon non-detachable cable;
Overvoltage protection;
Description
Voltage
Duration
Normal operation
+6 ... +30 V
Unlimited
Protection turns on, device turns off
34 V
Unlimited
Maximum voltage
<70 V
Unlimited
Maximum voltage impulse
90 V
5ms
Technical features
Part name
Physical specification
Navigation indication
LED
Modem indication
LED
Socket
Soldered inner socket
USB
Micro USB socket
Technical details
2 W max. Current consumption at 12 V (Power supply 6...30 V DC)
GPRS: average 50 mA Nominal: average 35 mA GNSS sleep: average 5.58 mA Deep Sleep: average 4.06 mA Online Deep Sleep: average 4.62 mA Ultra Deep Sleep: average 2.08 mA Rated current: 250 mA
Operating temperature
-40 ... +85 °C
Storage temperature
-40 ... +85 °C
Storage relative humidity
5 ... 95% (no condensation)
Device + case weight
50 g
Dimension drawing:
Electrical characteristics
Characteristic description
Value
Min.
Typ.
Max.
Unit
Supply Voltage:
Supply Voltage (Recommended Operating Conditions)
6
30
V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF)
120
µA
Drain current (Digital Output ON, Recommended Operating Conditions)
0.1
0.5
A
Digital Input:
300
mΩ
Digital Output (Open Drain grade):
Input resistance (DIN1)
47
kΩ
Input voltage (Recommended Operating Conditions)
0
Supply voltage
V
Input Voltage threshold (DIN1)
4
V
Analog Input:
Input voltage (Recommended Operating Conditions)
0
30
V
Input resistance
150
kΩ
Measurement error on 12 V
3
%
Additional error on 12 V
360
mV
Measurement error on 30 V
3
%
Additional error on 30 V
900
mV
Analog Input error margin can increase if temperature varies.
Absolute maximum ratings
Characteristic description
Value
Min.
Typ.
Max.
Unit
Supply Voltage (Absolute Maximum Ratings)
-32
+32
V
Drain-Source clamp threshold voltage (Absolute Maximum Ratings), (Idrain = 2 mA)