FTC961 Teltonika Data Sending Parameters ID
Main Page > Basic Trackers > FTC961 > FTC961 Teltonika Data Sending Parameters ID
Teltonika devices send data in packets that follow a specific structure, as defined on our Codec page. Each parameter in a record is identified by a Data Sending ID (AVL ID). These IDs are used to extract the correct values from the hexadecimal data during processing on the server side.
This page lists all available AVL IDs for FTC961. Differences in AVL IDs between the FT and legacy FMB platforms are described on the dedicated page. Property IDs in the AVL packet that differ between platforms are marked in bold.
The document is based on firmware version 2.1.1 or newer. AVL IDs are grouped into the following parameter groups:
Permanent I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Min Value | Max Value | Multiplier | Units | Description | Parameter Group |
---|---|---|---|---|---|---|---|---|---|
1 | Digital Input 1 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | Permanent I/O elements |
4 | Pulse counter DIN1 | 1 | Unsigned | 0 | - | - | - | Pulse counts between records on DIN1 | Permanent I/O elements |
9 | Analog Input 1 | 2 | Unsigned | 0 | 65535 | 0.001 | V | Voltage | Permanent I/O elements |
16 | Total Odometer | 4 | Unsigned | 0 | 2147483647 | - | m | Virtual odometer value | Permanent I/O elements |
17 | Axis X | 2 | Signed | -8000 | 8000 | - | mg | Axis X value | Permanent I/O elements |
18 | Axis Y | 2 | Signed | -8000 | 8000 | - | mg | Axis Y value | Permanent I/O elements |
19 | Axis Z | 2 | Signed | -8000 | 8000 | - | mg | Axis Z value | Permanent I/O elements |
21 | GSM Signal | 1 | Unsigned | 0 | 5 | - | - | Value in range 1-5 | Permanent I/O Elements |
67 | Battery Voltage | 2 | Unsigned | 0 | 65535 | - | mV | Voltage | Permanent I/O elements |
68 | Battery Current | 2 | Unsigned | 0 | 65535 | - | mA | Current | Permanent I/O elements |
69 | GNSS Status | 1 | Unsigned | 0 | 3 | - | - | 0 - GNSS OFF 1 - GNSS ON with fix 2 - GNSS ON without fix 3 - GNSS sleep |
Permanent I/O elements |
70 | PCB temperature | 2 | Signed | -550 | 1150 | - | °C | Degrees | Permanent I/O elements |
113 | Battery level | 1 | Unsigned | 0 | 100 | - | °C | Battery capacity level | Permanent I/O elements |
841 | Digital Output 1 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | Permanent I/O elements |
181 | GNSS PDOP | 2 | Unsigned | 0 | 500 | - | m | GNSS position dilution of precision. Normal PDOP is below 3 – the lower the number, the more accurate reported location is. |
Permanent I/O elements |
182 | GNSS HDOP | 2 | Unsigned | 0 | 500 | - | m | GNSS horizontal dilution of precision. Normal HDOP is below 2 – the lower the number, the more accurate reported location is. |
Permanent I/O elements |
199 | Trip Odometer | 4 | Unsigned | 0 | 2147483647 | - | m | Trip distance value calculated by GNSS | Permanent I/O elements |
200 | Sleep mode | 1 | Unsigned | 0 | 2 | - | - | TBA | Permanent I/O elements |
205 | GSM Cell ID | 4 | Unsigned | 0 | 2147483647 | - | - | GSM base station ID | Permanent I/O elements |
206 | GSM Area Code | 2 | Unsigned | 0 | 65535 | - | - | Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. | Permanent I/O elements |
237 | Network Type | 1 | Unsigned | 0 | 1 | - | - | 0 - 3G 1 - GSM 2 - 4G 3 - LTE CAT M1 4 - LTE CAT NB1 99 - Unknown |
Permanent I/O elements |
239 | Ignition | 1 | Unsigned | 0 | 1 | - | - | 0 – Ignition Off 1 – Ignition On |
Permanent I/O Elements |
240 | Movement | 1 | Unsigned | 0 | 1 | - | - | 0 – Movement Off 1 – Movement On |
Permanent I/O Elements |
241 | GSM operator code | 4 | Unsigned | 0 | 4294967295 | - | - | Currently used GSM Operator code | Permanent I/O elements |
303 | Instant Movement | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 returns movement value | Permanent I/O elements |
383 | Accel calibration status | 1 | Unsigned | 0 | 1 | - | - | 0 - not calibrated (empty) 1 - calibrated, but not fully (present) 2 - disabled 3 - fully calibrated (full) |
Permanent I/O elements |
641 | ICCID | 22 | ASCII | 0 | 22 | - | - | Value of SIM ICCID (Integrated circuit card identification number) | Permanent I/O elements |
800 | External Voltage | 2 | Unsigned | 0 | 4294967295 | - | mV | Voltage | Permanent I/O elements |
841 | Digital Output 1 Overcurrent | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | Permanent I/O elements |
1148 | Connectivity quality | 4 | Unsigned | 0 | 2147483647 | - | dBm | Provides detailed signal quality information in LTE, eMTC (CAT-Mx) and NB-IoT modes: RSSI (byte 0): 0 - 255 in dBm (negative values) RSRP (byte 1): 0 - 255 in dBm (negative values) SINR (byte 2): 0 - 250 which translates to -20dB to +30dB (1/5th of dB) RSRQ (byte 3): 0 - 255 in dB (negative values) |
Permanent I/O elements |
13361 | Incoming call detection | 1 | Unsigned | 0 | 1 | - | - | 0 – no incoming call 1 – an incoming call is in progress |
Permanent I/O elements |
Eventual I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Min Value | Max Value | Multiplier | Units | Description | Parameter Group |
---|---|---|---|---|---|---|---|---|---|
247 | Crash detection | 1 | Unsigned | 1 | 6 | - | - | 1 – crash 2 – limited crash trace (device not calibrated) 3 - limited crash trace (device is calibrated) 4 - full crash trace (device not calibrated) 5 - full crash trace (device is calibrated) 6 - crash detected (device not calibrated) |
Eventual I/O elements |
257 | Crash trace data | 1200 | HEX | 0 | 1200 | - | - | Crash trace data | Eventual I/O elements |
1429 | Crash average vector | 8 | Unsigned | - | - | - | mG | Stores the average vector calculated during the crash: 2B - X axis, 2B - Y axis, 2B - Z axis, 2B - magnitude in mG. | Eventual I/O elements |
1430 | Crash direction | - | Unsigned | - | - | - | - | Stores the indication if the accelerometer is calibrated. Also, indicates the direction of the crash. 1 bit (highest bit) indicates calibration status, rest of the bits indicates crash direction. |
Eventual I/O elements |
1431 | Crash duration | - | Unsigned | - | - | - | - | Duration of the crash event | Eventual I/O elements |
1432 | Crash max vector | 8 | Unsigned | - | - | - | mG | Stores the max vector calculated during the crash: 2B - X axis, 2B - Y axis, 2B - Z axis, 2B - magnitude in mG. | Eventual I/O elements |
255 | Over Speeding | 1 | Unsigned | 0 | 255 | - | km/h | At over speeding start km/h, at over speeding end km/h | Eventual I/O elements |
250 | Trip | 1 | Unsigned | 0 | 1 | - | - | 0 – trip stop 1 – trip start 2 – Business Status 3 – Private Status 4-9 – Custom Statuses |
Eventual I/O elements |
253 | Eco driving type | 1 | Unsigned | 1 | 3 | - | - | 1 – harsh acceleration 2 – harsh braking 3 – harsh cornering |
Eventual I/O elements |
254 | Eco driving value | 1 | Unsigned | 0 | 255 | acc and braking: 0.01 | G or rad |
Depending on Eco driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g). If Eco driving source is „GPS“ – harsh cornering value is rad/s*100. If source is „Accelerometer“ – g*100. | Eventual I/O elements |
251 | Excessive idling | 1 | Unsigned | 0 | 1 | - | - | 0 – moving 1 – idling |
Eventual I/O elements |
249 | Network jamming detection | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | Eventual I/O elements |
252 | Unplug detection | 1 | Unsigned | 0 | 1 | - | - | 0 – battery present 1 – battery unplugged |
Eventual I/O elements |
175 | Auto geofence | 1 | Unsigned | 0 | 1 | - | - | 0 – target left zone 1 – target enetered zone |
Eventual I/O elements |
246 | Towing detection | 1 | Unsigned | 0 | 1 | - | - | 0 – steady 1 – towing |
Eventual I/O elements |
358 | Custom scenario 1 | 1 | Unsigned | 0 | 1 | - | - | - | Eventual I/O elements |
359 | Custom scenario 2 | 1 | Unsigned | 0 | 1 | - | - | - | Eventual I/O elements |
360 | Custom scenario 3 | 1 | Unsigned | 0 | 1 | - | - | - | Eventual I/O elements |