Template:FMC225 firmware errata: Difference between revisions
no edit summary
No edit summary |
No edit summary |
||
Line 62: | Line 62: | ||
===Firmware versions=== | ===Firmware versions=== | ||
{| | {| style="width: 100%;" | ||
| | |- | ||
! style="width: 20%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: center;" |FIRMWARE VERSION | ! style="width: 20%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: center;" |FIRMWARE VERSION | ||
! style="width: 20%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: center;" |RELEASE DATE | ! style="width: 20%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: center;" |RELEASE DATE | ||
! style="width: 60%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;" |CHANGES | ! style="width: 60%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;" |CHANGES | ||
|- | |||
|style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: center; vertical-align: center; background: white;" |<span class="mw-headline" id="03.29.00.Rev.21">{{{fw|'''03.29.00.Rev.21'''}}}</span><br /> (recommended for FMB122, FMB125, FMC125 (SLM320-LA, SLM320-E2, EC21-EC), FMC920) | |||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: center; vertical-align: center; background: white;" |{{{release_date| 2024.08.07}}} | |||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: top; background: white;" | | |||
* Optimized the startup process of the network modules to improve pass-rate during manufacturing testing. | |||
* Dual SIM switching enhancements to improve pass-rate during manufacturing testing. | |||
* Return real SIM slot for factory testing commands. | |||
|- | |||
|style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: center; vertical-align: center; background: white;" |<span class="mw-headline" id="03.29.00.Rev.18">{{{fw|'''03.29.00.Rev.18'''}}}</span><br /> (recommended for FMT100, FMB900, FMB910, FMB920, FMC920, FMM920, FMB110, FMB120, FMB122, FMB130, FMC130 (SLM320-LA, SLM320-E2, EC21-EC, EC21-AU), FMC13A, FMM130 (BG95-M3, BG96), FMM13A, FMB202, FMB204, FMB206, FMB230, FMC230, FMM230, FMB140, FMB240, FMB125, FMC125 (SLM320-LA, SLM320-E2, EC21-EC), FMM125 (BG95-M3), FMB225, FMC225 | |||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: center; vertical-align: center; background: white;" |{{{release_date| 2024.05.13}}} | |||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: top; background: white;" | | |||
* Improved reconnection to new operator time if GPRS was unavailable with initial operator | |||
* Fixed pro-longed reconnection to new operator due to record tasks interrupting operator search | |||
* Fixed network session closing when current operator is added to blacklist | |||
* Improved module initialization time for devices with Quectel modems | |||
* Fixed Digital Output state restore after firmware update | |||
* RS232 interface stability improvements | |||
* GNSS status element state improvements | |||
* Time synchronization improvements | |||
* Manufacture testing improvements | |||
|- | |- | ||
|style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: center; vertical-align: center; background: white;" |<span class="mw-headline" id="03.29.00.Rev.14">{{{fw|'''03.29.00.Rev.14'''}}}</span><br /> (recommended for FMB120, FMB130, FMB140, FMB125, FMM130 with BG95-M3, FMM230, FMB920, FMT100, FMB910, FMB204, FMC125 with MeiG SLM320, FMC225, FMC13A) | |style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: center; vertical-align: center; background: white;" |<span class="mw-headline" id="03.29.00.Rev.14">{{{fw|'''03.29.00.Rev.14'''}}}</span><br /> (recommended for FMB120, FMB130, FMB140, FMB125, FMM130 with BG95-M3, FMM230, FMB920, FMT100, FMB910, FMB204, FMC125 with MeiG SLM320, FMC225, FMC13A) |