Changes

no edit summary
Line 1,308: Line 1,308:  
         <td style="width: 25%; text-align:center; vertical-align:middle;">Movement count value of EYE Sensor 4</td>
 
         <td style="width: 25%; text-align:center; vertical-align:middle;">Movement count value of EYE Sensor 4</td>
 
     </tr>
 
     </tr>
 
+
        <tr>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">10840</td>
 +
        <td style="width: 20%; text-align:center; vertical-align:middle;">EYE Magnet count 1</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">2</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">unsigned</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">0</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">65535</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">-</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">-</td>
 +
        <td style="width: 25%; text-align:center; vertical-align:middle;">Magnet trigger count measure by EYE Sensor 1</td>
 +
    </tr>
 +
        <tr>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">10841</td>
 +
        <td style="width: 20%; text-align:center; vertical-align:middle;">EYE Magnet count 2</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">2</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">unsigned</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">0</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">65535</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">-</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">-</td>
 +
        <td style="width: 25%; text-align:center; vertical-align:middle;">Magnet trigger count measure by EYE Sensor 2</td>
 +
    </tr>
 +
        <tr>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">10842</td>
 +
        <td style="width: 20%; text-align:center; vertical-align:middle;">EYE Magnet count 3</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">2</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">unsigned</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">0</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">65535</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">-</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">-</td>
 +
        <td style="width: 25%; text-align:center; vertical-align:middle;">Magnet trigger count measure by EYE Sensor 3</td>
 +
    </tr>
 +
        <tr>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">10843</td>
 +
        <td style="width: 20%; text-align:center; vertical-align:middle;">EYE Magnet count 2</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">2</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">unsigned</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">0</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">65535</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">-</td>
 +
        <td style="width: 5%; text-align:center; vertical-align:middle;">-</td>
 +
        <td style="width: 25%; text-align:center; vertical-align:middle;">Magnet trigger count measure by EYE Sensor 4</td>
 +
    </tr>
 
</table>
 
</table>
      
Eye sensor parameters have error code values, which will written to the I/O value if parameter data is not received. From the error code value, it is possible to distinguish whether the issue is on the FM tracker side or the EYE Sensor. Below is a table describing these values.
 
Eye sensor parameters have error code values, which will written to the I/O value if parameter data is not received. From the error code value, it is possible to distinguish whether the issue is on the FM tracker side or the EYE Sensor. Below is a table describing these values.

Navigation menu