Changes

Created page with "== DOUT Control Via Call== {{{pic_dout_control|300px|right}}} Scenario is activated and digital output is ON when call is received from a..."
== DOUT Control Via Call==

{{{pic_dout_control|[[Image:Fmb120_dout_via_call.png|300px|right]]}}}

Scenario is activated and digital output is ON when call is received from a number which is on the authorized numbers list.<br/>
Call control functionality is following:
* When {{{model|FMB2YX}}} is configured to control {{{text_dout|DOUT1/DOUT2}}} the device waits for an incoming call from a configured secure number. If a call is received {{{model|FMB2YX}}} turns on {{{text_dout|DOUT1/DOUT2}}} for a user defined ''Duration Timeout''. If duration timeout set to "0" {{{text_dout|DOUT1/DOUT2}}} will be OFF.
* {{{text_dout|DOUT1/DOUT2}}} can be turned off by ''Duration Timeout'' or by {{{text_din|digital input 1, digital input 2 or digital input 3}}}.
* {{{text_dout|DOUT1/DOUT2}}} will always be ON if, for example, DOUT deactivation is set to DIN1, but DIN1 will be never turned ON, or when duration timeout is set to maximum value (2147483647) which is about 68 years.

==Immobilizer==

{{{pic_immobilizer|[[Image:Fmb120_immobilizer.png|300px|right]]}}}

If ''DOUT Control'' is disabled, scenario will only generate events without digital output activation. If ''DOUT Control'' is enabled {{{text_dout|DOUT1/DOUT2}}} turns ON if ignition turns ON (''Ignition Source'' is configured to 1). After any iButton ID is attached, {{{text_dout|DOUT1/DOUT2}}} turns OFF. After iButton identification configured ''Ignition Source'' can be turned OFF (''Ignition Source'' is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If ''iButton List Check'' parameter is enabled, authorization will be successful only if the attached iButton is specified in iButton list.
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>

==iButton Read Notification==

{{{pic_ibutton_read|[[Image:Fmb120_iButton_read.png|300px|right]]}}}

This functionality allows user to see when iButton is read. {{{text_dout|DOUT1/DOUT2}}} turns on for a configured duration and after DOUT ON duration ends {{{text_dout|DOUT1/DOUT2}}} does not turn on even if iButton is left attached.