Line 5: |
Line 5: |
| * {{{model|FMB1YX}}} has to be configured to work in GPS Sleep mode and sleep timeout is reached; | | * {{{model|FMB1YX}}} has to be configured to work in GPS Sleep mode and sleep timeout is reached; |
| * Device must have time synchronized with GNSS satellites and have GPS fix; | | * Device must have time synchronized with GNSS satellites and have GPS fix; |
− | * No movement by configured movement source or movement sensor is detected; | + | * Movement is not detected by accelerometer{{{txt_movement| or configured movement source}}}; |
| {{{txt_ignition|* Ignition (configured ignition source) is off;}}} | | {{{txt_ignition|* Ignition (configured ignition source) is off;}}} |
| * Forced wakeup is not set; | | * Forced wakeup is not set; |
Line 12: |
Line 12: |
| | | |
| {{{model|FMB1YX}}} exits GPS sleep mode if {{{txt_exit|ONE of following conditions}}} is true: | | {{{model|FMB1YX}}} exits GPS sleep mode if {{{txt_exit|ONE of following conditions}}} is true: |
− | * Movement by accelerometer or configured movement source is detected; | + | * Movement by accelerometer{{{txt_movement| or configured movement source}}}; |
| {{{txt_ignition|* Ignition (configured ignition source) is turned on.}}} | | {{{txt_ignition|* Ignition (configured ignition source) is turned on.}}} |
| | | |
Line 22: |
Line 22: |
| * Device must have time synchronized with GNSS satellites and have GPS fix; | | * Device must have time synchronized with GNSS satellites and have GPS fix; |
| {{{txt_ignition|* Ignition (configured ignition source) is off;}}} | | {{{txt_ignition|* Ignition (configured ignition source) is off;}}} |
− | * Movement is not detected by accelerometer or configured movement source; | + | * Movement is not detected by accelerometer{{{txt_movement| or configured movement source}}}; |
| * ''Min. Record Saving Period'' ({{{ctrDaq|[[{{{model|FMB1YX}}} Data acquisition settings|Data Acquisition Mode settings]]}}}) must be larger than ''Open Link Timeout'' parameter, so that {{{model|FMB1YX}}} could close GPRS link; | | * ''Min. Record Saving Period'' ({{{ctrDaq|[[{{{model|FMB1YX}}} Data acquisition settings|Data Acquisition Mode settings]]}}}) must be larger than ''Open Link Timeout'' parameter, so that {{{model|FMB1YX}}} could close GPRS link; |
| * The difference between ''Send Period'' ({{{ctrDaq|[[{{{model|FMB1YX}}} Data acquisition settings|Data Acquisition Mode settings]]}}}) and ''Open Link Timeout'' must be more than 90 seconds, so that {{{model|FMB1YX}}} could close GPRS link within at least 90 seconds; | | * The difference between ''Send Period'' ({{{ctrDaq|[[{{{model|FMB1YX}}} Data acquisition settings|Data Acquisition Mode settings]]}}}) and ''Open Link Timeout'' must be more than 90 seconds, so that {{{model|FMB1YX}}} could close GPRS link within at least 90 seconds; |
Line 33: |
Line 33: |
| | | |
| {{{model|FMB1YX}}} exits deep sleep mode if {{{txt_exit|ONE of following conditions}}} is true: | | {{{model|FMB1YX}}} exits deep sleep mode if {{{txt_exit|ONE of following conditions}}} is true: |
− | * Movement by accelerometer or configured movement source is detected; | + | * Movement by accelerometer{{{txt_movement| or configured movement source}}} is detected; |
| {{{txt_ignition|* Ignition (configured ignition source) is turned on.}}} | | {{{txt_ignition|* Ignition (configured ignition source) is turned on.}}} |
| | | |
Line 40: |
Line 40: |
| Conditions to enter Online Deep Sleep mode are the same as entering Deep Sleep mode. | | Conditions to enter Online Deep Sleep mode are the same as entering Deep Sleep mode. |
| {{{model|FMB1YX}}} exits Online Sleep mode if {{{txt_exit|ONE of following conditions}}} is true: | | {{{model|FMB1YX}}} exits Online Sleep mode if {{{txt_exit|ONE of following conditions}}} is true: |
− | * Movement by accelerometer or configured movement source is detected; | + | * Movement by accelerometer{{{txt_movement| or configured movement source}}} is detected; |
| {{{txt_ignition|* Ignition (configured ignition source) is turned on.}}} | | {{{txt_ignition|* Ignition (configured ignition source) is turned on.}}} |
| | | |
| {{{ultra_ds|==Ultra Deep Sleep mode== | | {{{ultra_ds|==Ultra Deep Sleep mode== |
| Ultra battery saving mode, where GPS and GSM modem are turned off and device functions are suspended for maximum battery saving.<br/>Conditions to enter Ultra Deep Sleep mode are the same as entering Deep Sleep mode.<br/>{{{model|FMB1YX}}} exits Ultra Deep Sleep mode only when {{{txtIgnition|DIN1 and movement are}}} detected by accelerometer. Movement source {{{txt_ignition|and Ignition source configuration }}}is not taken into account in this case.}}} | | Ultra battery saving mode, where GPS and GSM modem are turned off and device functions are suspended for maximum battery saving.<br/>Conditions to enter Ultra Deep Sleep mode are the same as entering Deep Sleep mode.<br/>{{{model|FMB1YX}}} exits Ultra Deep Sleep mode only when {{{txtIgnition|DIN1 and movement are}}} detected by accelerometer. Movement source {{{txt_ignition|and Ignition source configuration }}}is not taken into account in this case.}}} |