Line 62: |
Line 62: |
| ! style="text-align: left; vertical-align: top;" | ''[[FMB readio|readio]] #'' | | ! style="text-align: left; vertical-align: top;" | ''[[FMB readio|readio]] #'' |
| | style="text-align: left; vertical-align: top;" | Returns IO status, # AVL ID. | | | style="text-align: left; vertical-align: top;" | Returns IO status, # AVL ID. |
| + | | style="text-align: left; vertical-align: top;" | Yes |
| + | |- |
| + | ! style="{{{hide_setdigout|}}}text-align: left; vertical-align: top;" | {{{cmd_setdigout|''[[FMB setdigout|setdigout]] ## Y1 Y2''}}} |
| + | | style="{{{hide_setdigout|}}}text-align: left; vertical-align: top;" | Set digital output.{{{txt_setdigout|<br/> |
| + | 1.# – 0 or 1 (0 - OFF or 1 – ON) for DOUT1.<br/> |
| + | 2.# – 0 or 1 (0 - OFF or 1 – ON) for DOUT2.<br/> |
| + | Y1 – timeout value for DOUT1 if needed (in seconds).<br/> |
| + | Y2 – timeout value for DOUT2 if needed (in seconds).}}} |
| + | | style="text-align: left; vertical-align: top;" | Yes |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | ''[[FMB battery|setdigout X Z Y]]'' |
| + | | style="text-align: left; vertical-align: top;" | set selected digital output<br/> |
| + | X – number of Digital output (1 – digital output 1; 2 – digital output 2).<br/> |
| + | Z – activate(1)/deactivate(0).<br/ > |
| + | Y – activation/deactivation timeout.<br/> |
| | style="text-align: left; vertical-align: top;" | Yes | | | style="text-align: left; vertical-align: top;" | Yes |
| |- | | |- |
Line 88: |
Line 103: |
| 7.# - MODE (0-TCP/1-UDP). | | 7.# - MODE (0-TCP/1-UDP). |
| | style="text-align: left; vertical-align: top;" | No | | | style="text-align: left; vertical-align: top;" | No |
− | |-
| |
− | ! style="{{{hide_setdigout|}}}text-align: left; vertical-align: top;" | {{{cmd_setdigout|''[[FMB setdigout|setdigout]] ## Y1 Y2''}}}
| |
− | | style="{{{hide_setdigout|}}}text-align: left; vertical-align: top;" | Set digital output.{{{txt_setdigout|<br/>
| |
− | 1.# – 0 or 1 (0 - OFF or 1 – ON) for DOUT1.<br/>
| |
− | 2.# – 0 or 1 (0 - OFF or 1 – ON) for DOUT2.<br/>
| |
− | Y1 – timeout value for DOUT1 if needed (in seconds).<br/>
| |
− | Y2 – timeout value for DOUT2 if needed (in seconds).}}}
| |
− | | style="text-align: left; vertical-align: top;" | Yes
| |
− | |-
| |
− | ! style="text-align: left; vertical-align: top;" | ''[[FMB battery|setdigout X Z Y]]''
| |
− | | style="text-align: left; vertical-align: top;" | set selected digital output<br/>
| |
− | X – number of Digital output (1 – digital output 1; 2 – digital output 2).<br/>
| |
− | Z – activate(1)/deactivate(0).<br/ >
| |
− | Y – activation/deactivation timeout.<br/>
| |
− | | style="text-align: left; vertical-align: top;" | Yes
| |
| |- | | |- |
| ! style="text-align: left; vertical-align: top;" | ''readops'' | | ! style="text-align: left; vertical-align: top;" | ''readops'' |