{{Template:FMB FW development notice}}

Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values.
<br/><br/>
'''For devices with 2 digital outputs:<br>'''
Example:<br/>"setdigout 01 0 5" will set OUT2 to high level for 5 seconds, while OUT1 to low level.
<br/><br/>
To ignore one digital output value and make ON/OFF state only to another digital output enter question mark.
<br/><br/>
Example:<br/>"setdigout ?1" will set OUT2 to high level for indefinite period of time while OUT1 remains as it was set before.