− | <font size="+3"><span style=color:#104996>'''Mounting recommendations'''</span></font>
| + | =='''Mounting recommendations'''== |
| | | |
− | <font size="+2"><span style=color:#F49E21> 1. </span> Connecting wires </font> | + | * <big>Connecting wires</big> |
− | <font size="+1">
| + | ** Wires should be fastened to the other wires or non-moving parts. Try to avoid heat emitting and moving objects near the wires. |
− | * Wires should be fastened to the other wires or non-moving parts. Try to avoid heat emitting and moving objects near the wires. | + | ** The connections should not be seen very clearly. If factory isolation was removed while connecting wires, it should be applied again. |
− | * The connections should not be seen very clearly. If factory isolation was removed while connecting wires, it should be applied again. | + | ** If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied. |
− | * If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied. | + | ** Wires cannot be connected to the board computers or control units. |
− | * Wires cannot be connected to the board computers or control units. | + | * <big>Connecting power source</big> |
− | </font> | + | ** Be sure that after the car computer falls asleep, power is still available on chosen wire. Depending on car, this may happen in 5 to 30 minutes period. |
| + | ** When module is connected, measure voltage again to make sure it did not decrease. |
| + | ** It is recommended to connect to the main power cable in the fuse box. |
| + | ** Use 3A, 125V external fuse. |
| + | * <big>Connecting ignition wire</big> |
| + | ** Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine. |
| + | ** Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available). |
| + | ** Check if power is still available when you turn off any of vehicles devices. |
| + | ** Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen. |
| + | * <big>Connecting ground wire</big> |
| + | ** Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame. |
| + | ** If the wire is fixed with the bolt, the loop must be connected to the end of the wire. |
| + | ** For better contact scrub paint from the spot where loop is going to be connected. |
| | | |
− | <font size="+2"><span style=color:#F49E21> 2. </span> Connecting power source. </font>
| + | ==<span style=color:#FF0000>'''Safety information'''</span>== |
− | <font size="+1">
| |
− | * Be sure that after the car computer falls asleep, power is still available on chosen wire. Depending on car, this may happen in 5 to 30 minutes period.
| |
− | * When module is connected, measure voltage again to make sure it did not decrease.
| |
− | * It is recommended to connect to the main power cable in the fuse box.
| |
− | * Use 3A, 125V external fuse.
| |
− | </font>
| |
− | | |
− | <font size="+2"><span style=color:#F49E21> 3. </span> Connecting ignition wire. </font>
| |
− | <font size="+1">
| |
− | * Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
| |
− | * Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
| |
− | * Check if power is still available when you turn off any of vehicles devices.
| |
− | * Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen.
| |
− | </font>
| |
− | | |
− | <font size="+2"><span style=color:#F49E21> 4. </span> Connecting ground wire. </font>
| |
− | <font size="+1">
| |
− | * Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
| |
− | * If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
| |
− | * For better contact scrub paint from the spot where loop is going to be connected.
| |
− | </font>
| |
− | | |
− | | |
− | <font size="+3"><span style=color:#FF0000>'''Safety information'''</span></font><br/>
| |
− | <font size="+2">
| |
| This message contains information on how to operate {{{model|FMB1YX}}} safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!<br/> | | This message contains information on how to operate {{{model|FMB1YX}}} safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!<br/> |
| The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed voltage range is {{{voltage|+6..+30}}} V DC.<br/> | | The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed voltage range is {{{voltage|+6..+30}}} V DC.<br/> |
Line 42: |
Line 29: |
| The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 60950-1 standard.<br/> | | The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 60950-1 standard.<br/> |
| The device {{{model|FMB1YX}}} is not designed as a navigational device for boats.<br/> | | The device {{{model|FMB1YX}}} is not designed as a navigational device for boats.<br/> |
− | </font>
| |
− |
| |
| | | |
− | <font size="+3"><span style=color:#104996>'''Precautions'''</span></font>
| + | ===<span style=color:#104996>Precautions</span>=== |
− | <font size="+2">
| |
| {| class="wikitable" style="border-style: solid; border-width: 0px" | | {| class="wikitable" style="border-style: solid; border-width: 0px" |
| |+ | | |+ |
Line 71: |
Line 55: |
| | style="text-align: left; background: #F6F6FB;" | Installation and/or handling during a lightning storm is prohibited. | | | style="text-align: left; background: #F6F6FB;" | Installation and/or handling during a lightning storm is prohibited. |
| |} | | |} |