Changes

no edit summary
Line 26: Line 26:  
|-
 
|-
 
|}
 
|}
<br/><br/><br/><br/><br/>
+
<br/><br/><br/><br/><br/><br/><br/>
 
===Data output===
 
===Data output===
 
----
 
----
Line 47: Line 47:     
When vehicle speed exceeds configured maximum speed value the scenario is activated, an event record is generated{{{text_dout| and digital output status is changed to 1 when configured}}}.<br/>Scenario is active until detected speed decreases below the set parameter value.
 
When vehicle speed exceeds configured maximum speed value the scenario is activated, an event record is generated{{{text_dout| and digital output status is changed to 1 when configured}}}.<br/>Scenario is active until detected speed decreases below the set parameter value.
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
+
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
    
==Jamming==
 
==Jamming==
Line 54: Line 54:     
When jamming is detected the scenario is activated, an event record is generated{{{text_dout| and digital output status is changed to 1 when configured}}} once ''Jamming'' timeout runs out. If jamming ends during timeout countdown no event will be generated{{{text_dout| and output will not be controlled}}}.<br/>''Eventual Records'' parameter can be configured: when it is disabled scenario status value will appear in each AVL record, otherwise it will be appended only to eventual records.
 
When jamming is detected the scenario is activated, an event record is generated{{{text_dout| and digital output status is changed to 1 when configured}}} once ''Jamming'' timeout runs out. If jamming ends during timeout countdown no event will be generated{{{text_dout| and output will not be controlled}}}.<br/>''Eventual Records'' parameter can be configured: when it is disabled scenario status value will appear in each AVL record, otherwise it will be appended only to eventual records.
<br/><br/><br/><br/><br/><br/><br/><br/>
+
<br/><br/><br/><br/><br/><br/><br/>
    
{{{template_link|}}}
 
{{{template_link|}}}
Line 82: Line 82:     
If ''DOUT Control'' is disabled, scenario will only generate events without digital output activation. If ''DOUT Control'' is enabled {{{text_dout|DOUT1/DOUT2}}} turns ON if ignition turns ON (''Ignition Source'' is configured to 1). After any iButton ID is attached, {{{text_dout|DOUT1/DOUT2}}} turns OFF. After iButton identification configured ''Ignition Source'' can be turned OFF (''Ignition Source'' is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If ''iButton List Check'' parameter is enabled, authorization will be successful only if the attached iButton is specified in iButton list.
 
If ''DOUT Control'' is disabled, scenario will only generate events without digital output activation. If ''DOUT Control'' is enabled {{{text_dout|DOUT1/DOUT2}}} turns ON if ignition turns ON (''Ignition Source'' is configured to 1). After any iButton ID is attached, {{{text_dout|DOUT1/DOUT2}}} turns OFF. After iButton identification configured ''Ignition Source'' can be turned OFF (''Ignition Source'' is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If ''iButton List Check'' parameter is enabled, authorization will be successful only if the attached iButton is specified in iButton list.
<br/><br/><br/><br/><br/><br/><br/><br/><br/>}}}
+
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>}}}
    
{{{ibutton_feature|==iButton Read Notification==
 
{{{ibutton_feature|==iButton Read Notification==
Line 89: Line 89:     
This functionality allows user to see when iButton is read. {{{text_dout|DOUT1/DOUT2}}} turns on for a configured duration and after DOUT ON duration ends {{{text_dout|DOUT1/DOUT2}}} does not turn on even if iButton is left attached.
 
This functionality allows user to see when iButton is read. {{{text_dout|DOUT1/DOUT2}}} turns on for a configured duration and after DOUT ON duration ends {{{text_dout|DOUT1/DOUT2}}} does not turn on even if iButton is left attached.
<br/><br/><br/><br/><br/>}}}
+
<br/><br/><br/><br/><br/><br/><br/>}}}
    
{{{par_dout|==DOUT controls==
 
{{{par_dout|==DOUT controls==
 
Please refer to [[FMB964_DOUT_controls|DOUT controls]].}}}
 
Please refer to [[FMB964_DOUT_controls|DOUT controls]].}}}

Navigation menu