Changes

Line 56: Line 56:  
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
 
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
   −
==Authorized driving==
+
==Authorized driving/Immobilizer==
    
{{{pic_jamming|[[Image:FMB640_authorizedD.png|300px|right]]}}}
 
{{{pic_jamming|[[Image:FMB640_authorizedD.png|300px|right]]}}}
   −
If DOUT Control is disabled, scenario will only generate events without digital output activation. If DOUT Control is enabled DOUT1/DOUT2 turns ON if ignition turns ON (Ignition Source is configured to 1). After any iButton ID is attached, DOUT1/DOUT2/DOUT3 turns OFF. After iButton identification configured Ignition Source can be turned OFF (Ignition Source is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If iButton List Check parameter is enabled, authorization will be successful only if the attached iButton is specified in iButton list.
+
*If DOUT Control is disabled, scenario will only generate events without digital output activation. If DOUT Control is enabled DOUT1/DOUT2 turns ON if ignition turns ON (Ignition Source is configured to 1).  
info
+
* After any iButton ID is attached, DOUT1/DOUT2/DOUT3 turns OFF.  
Ignition off timeout parameter is used to set the duration after which authorization is activated, when ignition is turned off.  
+
* After iButton identification configured Ignition Source can be turned OFF (Ignition Source is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If * iButton List Check parameter is enabled, authorization will be successful only if the attached iButton is specified in iButton list. <br/>
Authorization off timeout parameter is used to set the duration how long the user has time to authorize after switching ignition on
+
* Ignition off timeout parameter is used to set the duration after which authorization is activated, when ignition is turned off. <br/>
iButton list gives ability to use vehicle for 1000 specific iButton owners (specified in iButton list). Selected DOUT is controlled by scenario for user needs, to manage buzzer, LED etc.
+
* Authorization off timeout parameter is used to set the duration how long the user has time to authorize after switching ignition on. <br/>
 +
* iButton list gives ability to use vehicle for 1000 specific iButton owners (specified in iButton list). Selected DOUT is controlled by scenario for user needs, to manage buzzer, LED etc.
 
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
 
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>