Created page with "==Ignition Source== FMM640 has 6 configurable Ignition sources: <br> 1. DIN1;<br> 2. DIN2;<br> 3. DIN3;<br> 4. DIN4;<br> 5. Movement;<br> 6. External Voltage;<br> Ignition so..."
==Ignition Source==
FMM640 has 6 configurable Ignition sources: <br>
1. DIN1;<br>
2. DIN2;<br>
3. DIN3;<br>
4. DIN4;<br>
5. Movement;<br>
6. External Voltage;<br>

Ignition source configuration works like this:
At least one Ignition source must be enabled. It is possible to enable all six sources as Ignition Source. <br>
DIN1 - 1;<br>
DIN2 - 2;<br>
DIN3 - 4;<br>
DIN4 - 8;<br>
Movement - 16;<br>
External Voltage - 32;<br>

Examples: <br>
In order to configure DIN1 as Ignition source, we send SMS: "setparam 101:1". SMS command will configure Ignition source as DIN1
In order to configure all sources as Ignition source, we send SMS: "setparam 101:63". Explanation why: DIN1 + DIN2 + DIN3 + DIN + Movement + External Voltage = 1 + 2 + 4 + 8 + 16 + 32 = 63

To configure other sources, simply add desired values together. I.e. DIN1 + External Voltage = 1 + 32 = 33 - "setparam 101:33"

Min: 1, Max: 63 <br>