Changes

no edit summary
Line 2: Line 2:     
[[Image:FMB640_can_connx_diagram.png|350px|none]]
 
[[Image:FMB640_can_connx_diagram.png|350px|none]]
LV-CAN200 is used to read data from light vehicles, while ALL-CAN300 is used to read data from any type of transport: light vehicles, trucks, buses, agriculture transport and other special transport. Using these adapters {{{model|FMB640}}} device is able to collect and send vehicle data.
+
LV-CAN200 is used to read data from light vehicles, while ALL-CAN300 is used to read data from any type of transport: light vehicles, trucks, buses, agriculture transport and other special transport. Using these adapters {{{model|FMM640}}} device is able to collect and send vehicle data.
    
{| class="wikitable"
 
{| class="wikitable"
Line 63: Line 63:  
When power supply is connected, the LED shines continuously. It means that device is waiting for calibration. '''Calibration process''' has to be carried out when CAN-BUS twisted pair is tightened on SIMPLE-CAN and when ignition is ON. Please press the switch briefly and wait for the LED to start blinking every second. Automatic calibration process takes up to 10 seconds depending on the vehicle's model. Correct calibration process is confirmed by LED starting to blink every 2 seconds (when the CAN-BUS is active). When the CAN-BUS enters sleep mode, SIMPLE-CAN device also enters sleep mode and takes 1.6mA @ 12V. In the sleep mode LED does not shine. If after calibration process LED shines continuously, it means that device is not calibrated yet, CAN-BUS transmission has failed or ignition during calibration was not ON.
 
When power supply is connected, the LED shines continuously. It means that device is waiting for calibration. '''Calibration process''' has to be carried out when CAN-BUS twisted pair is tightened on SIMPLE-CAN and when ignition is ON. Please press the switch briefly and wait for the LED to start blinking every second. Automatic calibration process takes up to 10 seconds depending on the vehicle's model. Correct calibration process is confirmed by LED starting to blink every 2 seconds (when the CAN-BUS is active). When the CAN-BUS enters sleep mode, SIMPLE-CAN device also enters sleep mode and takes 1.6mA @ 12V. In the sleep mode LED does not shine. If after calibration process LED shines continuously, it means that device is not calibrated yet, CAN-BUS transmission has failed or ignition during calibration was not ON.
   −
==Connecting {{{model|FMB640}}} CAN adapters ALL-CAN300 and LV-CAN200==
+
==Connecting {{{model|FMM640}}} CAN adapters ALL-CAN300 and LV-CAN200==
   −
Connect USB Plug to {{{model|FMB640}}} device, connect Light Vehicles Can adapter to other end of the cable.
+
Connect USB Plug to {{{model|FMM640}}} device, connect Light Vehicles Can adapter to other end of the cable.
 
Connect Light Vehicles Can adapter Pin 1 and Pin 2 to cars CAN bus. CAN interface location of the supported light vehicle is described on mounting scheme.
 
Connect Light Vehicles Can adapter Pin 1 and Pin 2 to cars CAN bus. CAN interface location of the supported light vehicle is described on mounting scheme.
 
Connect car power supply lines to Pin 3 positive, Pin 4 Negative.
 
Connect car power supply lines to Pin 3 positive, Pin 4 Negative.
Line 84: Line 84:  
|}
 
|}
   −
=={{{model|FMB640}}} ALL-CAN300 and LV-CAN200 parameters configuration==
+
=={{{model|FMM640}}} ALL-CAN300 and LV-CAN200 parameters configuration==
   −
Because {{{model|FMB640}}} have LV-CAN200/ALL-CAN300 RX and TX in its own pinout, device configuration can be performed via micro-USB when CAN adapter is connected to the vehicle.<br/>When {{{model|FMB640}}} is connected to LV-CAN200 or ALL-CAN300, user can see all information that is received from the vehicle in configurator LVCAN section, all data are highlighted by green background color. Information in this section is automatically refreshed. CAN bus data which can be read from your car is provided in "Light or All Vehicles CAN adapter supported cars" document.<br/>The LVCAN I/O element can be configured like any other I/O element in {{{model|FMB640}}} configurator.
+
Because {{{model|FMM640}}} have LV-CAN200/ALL-CAN300 RX and TX in its own pinout, device configuration can be performed via micro-USB when CAN adapter is connected to the vehicle.<br/>When {{{model|FMM640}}} is connected to LV-CAN200 or ALL-CAN300, user can see all information that is received from the vehicle in configurator LVCAN section, all data are highlighted by green background color. Information in this section is automatically refreshed. CAN bus data which can be read from your car is provided in "Light or All Vehicles CAN adapter supported cars" document.<br/>The LVCAN I/O element can be configured like any other I/O element in {{{model|FMM640}}} configurator.
   −
When using offline configuration method user can select which CAN data will be read from LV-CAN200 or ALL-CAN300 and sent directly to the server without connection to adapter. Please note that parameters depend on vehicle manufacturer and vehicle model. For further information check "Light and All Vehicles CAN adapter supported cars” document.<br/>All information about I/O element parameters description is in section [[{{{model|FMB640}}} I/O settings|I/O settings]].<br/>All LV-CAN200/ALL-CAN300 I/O parameters configuration settings are described in "{{{model|FMB640}}} Protocols" document, except ALL-CAN300 bitmasks, which are described in the table below.
+
When using offline configuration method user can select which CAN data will be read from LV-CAN200 or ALL-CAN300 and sent directly to the server without connection to adapter. Please note that parameters depend on vehicle manufacturer and vehicle model. For further information check "Light and All Vehicles CAN adapter supported cars” document.<br/>All information about I/O element parameters description is in section [[{{{model|FMM640}}} I/O settings|I/O settings]].<br/>All LV-CAN200/ALL-CAN300 I/O parameters configuration settings are described in "{{{model|FMM640}}} Protocols" document, except ALL-CAN300 bitmasks, which are described in the table below.
    
{| class="wikitable"
 
{| class="wikitable"
Line 138: Line 138:  
==Send data with 0, if ignition is off==
 
==Send data with 0, if ignition is off==
   −
Depending on LV-CAN200/ALL-CAN300 I/O parameters and ignition status, {{{model|FMB640}}} can send locked (last known) LV-CAN200/ALL-CAN300 I/O and active (real time) parameters values or reset values to 0. When ignition is off, LV-CAN200/ALL-CAN300 I/O parameters values sent to server are:
+
Depending on LV-CAN200/ALL-CAN300 I/O parameters and ignition status, {{{model|FMM640}}} can send locked (last known) LV-CAN200/ALL-CAN300 I/O and active (real time) parameters values or reset values to 0. When ignition is off, LV-CAN200/ALL-CAN300 I/O parameters values sent to server are:
    
{| class="wikitable"
 
{| class="wikitable"

Navigation menu