Changes

no edit summary
Line 3: Line 3:  
{{{pic_idling|[[Image:Fmb640_excessive_idling.png|300px|right]]}}}
 
{{{pic_idling|[[Image:Fmb640_excessive_idling.png|300px|right]]}}}
   −
If ignition (DIN1 or Power Voltage) is ON and vehicle is not moving, after configured time period FMB640 will generate event. When vehicle starts moving FMB640 after configured time period generate event that vehicle idle time ends. You can configure time it takes to turn on this scenario (Time to Stopped). Scenario is activated until vehicle starts moving and keeps moving (moving is detected only from accelerometer) for amount of time that is configured. You can configure time it takes to turn OFF this scenario (Time to Stopped). .
+
If ignition (DIN1 or Power Voltage) is ON and vehicle is not moving, after configured time period FMC640 will generate event. When vehicle starts moving FMC640 after configured time period generate event that vehicle idle time ends. You can configure time it takes to turn on this scenario (Time to Stopped). Scenario is activated until vehicle starts moving and keeps moving (moving is detected only from accelerometer) for amount of time that is configured. You can configure time it takes to turn OFF this scenario (Time to Stopped). .
 
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
 
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
   Line 10: Line 10:  
[[Image:Fmb640_towing.png|250px|right]]
 
[[Image:Fmb640_towing.png|250px|right]]
   −
''Towing Detection'' feature helps to inform the driver about unexpected car movement when it was parked. {{{model|FMB640}}} generates an event when car is being towed or lifted, for example, in a case of vehicle evacuation. {{{model|FMB640}}} activates towing function when following conditions are met:
+
''Towing Detection'' feature helps to inform the driver about unexpected car movement when it was parked. {{{model|FMC640}}} generates an event when car is being towed or lifted, for example, in a case of vehicle evacuation. {{{model|FMC640}}} activates towing function when following conditions are met:
 
# Ignition (configured Ignition Source) is OFF.
 
# Ignition (configured Ignition Source) is OFF.
 
# ''Activation Timeout'' is reached.
 
# ''Activation Timeout'' is reached.
When towing function is engaged {{{model|FMB640}}} monitors accelerometer data. If acceleration ''Threshold'' or ''Angle'' reach configured values for a configured ''Duration'', and Ignition is still OFF for a period of time that is longer than ''Event Timeout'', then an event is generated. When configured, ''Make Call To'' and ''Send SMS To'' functions make a call or send an SMS to a predefined phone number. Towing function will be reactivated after {{{model|FMB640}}} detects a change of Ignition state from ON to OFF.
+
When towing function is engaged {{{model|FMC640}}} monitors accelerometer data. If acceleration ''Threshold'' or ''Angle'' reach configured values for a configured ''Duration'', and Ignition is still OFF for a period of time that is longer than ''Event Timeout'', then an event is generated. When configured, ''Make Call To'' and ''Send SMS To'' functions make a call or send an SMS to a predefined phone number. Towing function will be reactivated after {{{model|FMC640}}} detects a change of Ignition state from ON to OFF.
 
<br/><br/><br/><br/><br/><br/><br/>
 
<br/><br/><br/><br/><br/><br/><br/>
   Line 24: Line 24:  
1. Threshold (mg)  
 
1. Threshold (mg)  
 
2. Duration (ms)  
 
2. Duration (ms)  
If accident happens and FMB640 detects acceleration value higher than set threshold value during set time period, then device will generate an event. Threshold and duration values are set depending of accident power which you want to detect. FMB640 can detect a slight tapping on the device (Threshold=100mg, Duration=1ms) or can detect severe accident (Threshold=4000mg, Duration=5ms).  
+
If accident happens and FMC640 detects acceleration value higher than set threshold value during set time period, then device will generate an event. Threshold and duration values are set depending of accident power which you want to detect. FMC640 can detect a slight tapping on the device (Threshold=100mg, Duration=1ms) or can detect severe accident (Threshold=4000mg, Duration=5ms).  
    
''Crash trace functionality'' <br>
 
''Crash trace functionality'' <br>
Line 30: Line 30:  
0. Disabled, <br>
 
0. Disabled, <br>
 
1. Trace Changes(Enable). <br>
 
1. Trace Changes(Enable). <br>
* FMB will collect acceleration data for configured trace duration. Every second Acceleration changed more then > 50mG Data will be collected and records generated. If Acceleration does not change, trace will save records with 1second period.  
+
* FMC will collect acceleration data for configured trace duration. Every second Acceleration changed more then > 50mG Data will be collected and records generated. If Acceleration does not change, trace will save records with 1second period.  
 
2. Trace Full. <br>
 
2. Trace Full. <br>
 
* It doesnt matter if axis changed more then >50mG or not all values will be added in buffer.
 
* It doesnt matter if axis changed more then >50mG or not all values will be added in buffer.

Navigation menu