==Physical connection to Mobileye 5 CAN-A port==
 
==Physical connection to Mobileye 5 CAN-A port==
The Mobileye 5 CAN interface (CAN Bus) is located in the Main unit (SeeQ/camera). The Typical SeeQ CAN Channel dedicated for FMS Integrations and similar communication is CAN-A channel. FMB640 devices uses CAN1 by default configuration for Mobileye to FM communications. <br>
+
The Mobileye 5 CAN interface (CAN Bus) is located in the Main unit (SeeQ/camera). The Typical SeeQ CAN Channel dedicated for FMS Integrations and similar communication is CAN-A channel. FMB640 devices uses CAN1 by default configuration for Mobileye to FM communications.  
+
 
[[Figure 1. FMB640 20-PIN output|Figure 1. FMB640 20-PIN output <br>]]
+
<br />[[File:Asset 1 v1.png|600x600px]]
 +
 
 +
 
 +
You need to connect this CAN bus interface to Mobileye CAN-A channel dedicated CAN bus interface for FMS units. In Mobileye 5 the CAN-A Channel is accessible for physical connection using the CAN-A Male connector, (6 Pins connector labeled “EyeCAN”) in the Mobileye 5 main harness.
   −
You need to connect this CAN bus interface to Mobileye CAN-A channel dedicated CAN bus interface for FMS units. In Mobileye 5 the CAN-A Channel is accessible for physical connection using the CAN-A Male connector, (6 Pins connector labeled “EyeCAN”) in the Mobileye 5 main harness. <br>
+
[[File:Mobileye-scheme (2).png|800x800px]]
  −
Figure 2. Mobileye 5 CAN-A 6 PIN male connector PIN layout <br>
      
FMB640 device CAN1 H signal must be connected to “EyeCAN” PIN1 and CAN1 L to PIN2. Please take a note that connectors for FMS devices (in this case FMB640) are not supplied. This connection cable should be provided for FMB64 CAN1 connection with Mobileye 5 “EyeCAN” port. <br> <br>
 
FMB640 device CAN1 H signal must be connected to “EyeCAN” PIN1 and CAN1 L to PIN2. Please take a note that connectors for FMS devices (in this case FMB640) are not supplied. This connection cable should be provided for FMB64 CAN1 connection with Mobileye 5 “EyeCAN” port. <br> <br>
Line 17: Line 18:     
==FMB640 device configuration==
 
==FMB640 device configuration==
Mobileye and FMB640 devices communicate through CAN bus. FMB640 CAN1 bus is dedicated for Mobileye to FM communication. As described in Mobileye documentation, default baud rate is 500 Kbps. Using configurator, in CAN\Tachograph tab, CAN1 Bus Settings, select 500 kbps CAN1 bus speed (kbps). <br>
+
Mobileye and FMB640 devices communicate through CAN bus. FMB640 CAN1 bus is dedicated for Mobileye to FM communication. As described in Mobileye documentation, default baud rate is 500 Kbps. Using configurator, in CAN\Tachograph tab, CAN1 Bus Settings, select 500 kbps CAN1 bus speed (kbps). Also, in CAN1 bus mode please select "Normal" option.
+
 
Figure 3. Bus speed configuration of CAN1 for Mobileye to FMB640 communication <br>
+
<br>[[File:FMB640 boudrate.png|800x800px]]
 +
 
    
User must select Codec8 Extended data type in order to get Mobileye data packets to server because Mobileye I/O AVL ID’s are over than 255. This is because of Codec8 Extended can sent 2 bytes data of AVL ID while Codec8 – 1 byte. This parameter is located in configurator System tab in Protocol Settings.
 
User must select Codec8 Extended data type in order to get Mobileye data packets to server because Mobileye I/O AVL ID’s are over than 255. This is because of Codec8 Extended can sent 2 bytes data of AVL ID while Codec8 – 1 byte. This parameter is located in configurator System tab in Protocol Settings.
When Codec8 Extended type is selected Mobileye IO elements could be selected. <br>
+
When Codec8 Extended type is selected Mobileye IO elements could be selected.  
+
 
Figure 4. Codec8 Extended parameter dropdown <br>
+
<br>[[File:FMB640 Codec8Extended tab 1.png]]
 +
 
    
'''Note:''' Mobileye records will be sent together with base AVL records. <br> <br>
 
'''Note:''' Mobileye records will be sent together with base AVL records. <br> <br>
 
'''Note:''' ME TSR IO elements are not parsed in FMB640 device, they must be parsed according to Mobileye documentation, because FMB640 will send 8 bytes size RAW data of those parameters. All other elements are already parsed and showing correct values. Simply select elements which you want to get and generation type as other FMB640 IO elements. <br>
 
'''Note:''' ME TSR IO elements are not parsed in FMB640 device, they must be parsed according to Mobileye documentation, because FMB640 will send 8 bytes size RAW data of those parameters. All other elements are already parsed and showing correct values. Simply select elements which you want to get and generation type as other FMB640 IO elements. <br>
 
   
 
   