Line 10: |
Line 10: |
| *Firmware version | | *Firmware version |
| *Last Start Time - last device start time. | | *Last Start Time - last device start time. |
− | *RTC Time - real time clock or current device time. | + | *RTC Time - real-time clock or current device time. |
| *Power Voltage (mV) | | *Power Voltage (mV) |
| *Device IMEI | | *Device IMEI |
Line 27: |
Line 27: |
| *Satellites | | *Satellites |
| **Visible - the amount and type of satellites that are visible. | | **Visible - the amount and type of satellites that are visible. |
− | **In Use - the amount of satellites used for location positioning. | + | **In Use - the number of satellites used for location positioning. |
| *Location | | *Location |
− | **Latitude/Longitude - shows current device coordinates and if you press them opens '''Object location''' window with map. | + | **Latitude/Longitude - shows current device coordinates and if you press them opens '''Object location''' window with a map. |
| **Altitude, Angle | | **Altitude, Angle |
| **HDOP, PDOP | | **HDOP, PDOP |
Line 43: |
Line 43: |
| **Signal Level | | **Signal Level |
| *GPRS traffic | | *GPRS traffic |
− | **Sent Data - the amount of data that has been sent by device. | + | **Sent Data - the amount of data that has been sent by the device. |
− | **Received Data - the amount of data that has been received by device. | + | **Received Data - the amount of data that has been received by the device. |
| **Total Traffic - Sent Data + Received Data | | **Total Traffic - Sent Data + Received Data |
| *Sockets information: | | *Sockets information: |
Line 50: |
Line 50: |
| **Socket - Closed or Server domain and port which is used when sending AVL Data via TCP/UDP. | | **Socket - Closed or Server domain and port which is used when sending AVL Data via TCP/UDP. |
| *Records | | *Records |
− | **Sent Records count - how many records were sent to the server since last data reset. | + | **Sent Records count - how many records were sent to the server since the last data reset. |
| **Last Record Send - date and time when the last record was sent. | | **Last Record Send - date and time when the last record was sent. |
| **Last Server Response Time - date and time when the last server response was. | | **Last Server Response Time - date and time when the last server response was. |
| *SMS Count | | *SMS Count |
− | **Received SMS - the amount of SMS messages device has received. | + | **Received SMS - the amount of SMS messages the device has received. |
| **Sent SMS - the amount of SMS responses that were sent from the device. | | **Sent SMS - the amount of SMS responses that were sent from the device. |
| **SMS Count - Received SMS + Sent SMS | | **SMS Count - Received SMS + Sent SMS |
Line 71: |
Line 71: |
| **Log - after button is pressed, the device starts log capturing for 10 minutes with configuration download. After this time device .log and configuration .cfg will be in compressed archive. <p>Archive name: <code>YYYY_MM_DD_HH_MM_SS_{{{model|FMB1YX}}}_IMEI_Log.zip</code><br>Default directory: <code>C:\Users\<username>\Documents</code></p> | | **Log - after button is pressed, the device starts log capturing for 10 minutes with configuration download. After this time device .log and configuration .cfg will be in compressed archive. <p>Archive name: <code>YYYY_MM_DD_HH_MM_SS_{{{model|FMB1YX}}}_IMEI_Log.zip</code><br>Default directory: <code>C:\Users\<username>\Documents</code></p> |
| [[File:logging.gif]] | | [[File:logging.gif]] |
− | **Dump - after button is pressed, the device starts to download .dmp logs and configuration .cfg from device in compressed archive. <p>Archive name: <code>YYYY_MM_DD_HH_MM_SS_{{{model|FMB1YX}}}_IMEI_Dump.zip</code><br>Default directory: <code>C:\Users\<username>\Documents</code><br>Dump files can be read only with special software. If needed, provide these files to your Teltonika sales manager or Teltonika Support team.</p>
| + | :*Dump - after button is pressed, the device starts to download .dmp logs and configuration .cfg from device in compressed archive. <p>Archive name: <code>YYYY_MM_DD_HH_MM_SS_{{{model|FMB1YX}}}_IMEI_Dump.zip</code><br>Default directory: <code>C:\Users\<username>\Documents</code><br>Dump files can be read only with special software. If needed, provide these files to your Teltonika sales manager or Teltonika Support team.</p> |
− | **Open directory - this button appears near '''Log''' or '''Dump''' if one of these functions were used.
| + | :*Open directory - this button appears near '''Log''' or '''Dump''' if one of these functions were used. |
− | *Accelerometer - after button is pressed, the device starts to capture accelerometer values for 1 second. | + | *Accelerometer - after the button is pressed, the device starts to capture accelerometer values for 1 second. |
| {{{txt_lls|==LLS Calibration== | | {{{txt_lls|==LLS Calibration== |
| * LLS calibration - in this section you can calculate calibration values of Analog LLS sensors for AVL server - create a polynom which is needed to convert sensor values to liters: | | * LLS calibration - in this section you can calculate calibration values of Analog LLS sensors for AVL server - create a polynom which is needed to convert sensor values to liters: |
− | | + | **Table is filled row by row. Each row represents one fuel tank fill. To calculate constants it is needed to select a sensor from ''„Available sensors“'', and fill the „Fuel, L.“ column and capture the current value of a sensor by clicking the ''"Refresh"'' button. Then the next value in liters should be entered by the user and so on. |
− | :::Table is filled row by row. Each row represents one fuel tank fill. To calculate constants it is needed to select a sensor from „Available sensors“, and fill „Fuel, L.“ column and capture current value of a sensor by clicking "Refresh" button. Then the next value in liters should be entered by user and so on.
| + | **When a table is filled, calculated a0, a1, a2, and a3 values should be seen. |
− | :::When table is filled, calculated a0, a1, a2 and a3 values should be seen.
| + | **To add a new tank fill row click "Add row". To remove the row click the ''"minus"'' button near the row you want to clear. To Clear all the rows click ''"Clear rows"''. |
− | :::To add a new tank fill row click "Add row". To remove the row click "minus" button near the row you want to clear. To Clear all the rows click "Clear rows".
| + | **By clicking ''"Export"'' data will be exported to .csv file. |
− | :::By clicking "Export" data will be exported to .csv file.
| + | **To recalculate the polynom click on ''"Calculate"'' button. |
− | :::To recalculate the polynom click on "Calculate" button.
| |
| | | |
| [[File:LLS_Calibration.png]] | | [[File:LLS_Calibration.png]] |
Line 89: |
Line 88: |
| | | |
| {{{txt_obd|==OBD Info== | | {{{txt_obd|==OBD Info== |
− | Shows the main OBD parameters with current values when the device is connected to the vehicle via OBDII socket or using [[{{{model|FMB120}}}_Bluetooth_settings#How_to_connect_OBD_II_Bluetooth_Dongle_to_FMB_device|OBDII Bluetooth Dongle]].}}} | + | Shows the main OBD parameters with current values when the device is connected to the vehicle via OBDII socket or using [[{{{model|FMB120}}}_Bluetooth_settings#How_to_connect_OBD_II_Bluetooth_Dongle_to_FMB_device|OBDII Bluetooth Dongle]]. |
| + | |
| + | '''Note:''' not all parameters which are displayed in the ''"OBD Info"'' tab can be readable from the vehicle.}}} |
| + | |
| {{{txt_can|==CAN Adapter Info== | | {{{txt_can|==CAN Adapter Info== |
− | Shows the parameters with current values (including program number and software version) from CAN {{{FMB140_CAN|adapter when the device is connected to LV-CAN200/ALL-CAN300/CAN-CONTROL.}}} }}} | + | Shows the parameters with current values (including program number and software version) from CAN {{{FMB140_CAN|adapter when the device is connected to [[LV-CAN200]]/[[ALL-CAN300]]/[[CAN-CONTROL]].}}} |
| + | |
| + | '''Note:''' not all parameters which are displayed in the ''"CAN Adapter Info"'' tab can be readable from the vehicle.}}} |