Changes

Created page with "SAE J1708 is a standard used for serial communications between ECUs on a heavy-duty. The hardware utilized is RS-485 transceivers wired for open collector operation through th..."
SAE J1708 is a standard used for serial communications between ECUs on a heavy-duty. The hardware utilized is RS-485 transceivers wired for open collector operation through the use of a pullup and pulldown of the separate data lines.

With {{{model|FMX640}}}, J1708 functionality is used to read vehicle's Fuel Level and Fuel consumption.

Because J1708 is not a CAN-BUS protocol, {{{model|FMX640}}} CAN1 and CAN2 lines cannot be used to read J1708 information. {{{model|FMX640}}} has a special J1708 Port, which utilizes an RJ9 4P4C connector.

[[Image:FMX640_and_J1708_illustration_v1.2.png]] <br>

==Software Configuration of {{{model|FMX640}}}with J1708==

{{{FMB640CFG|Firmware version: 00.00.11 or above
Configurator version: 0.13.35.29297 or above
}}}
J1708 configuration is done in the FMS IO Tab.

[[image:J1708_config.gif]]

When J1708 is enabled as Fuel Level source, Fuel related data will be taken from the J1708 line, FMS Fuel data will be ignored.

==Connection with Vehicle port==

J1708 connector is not supported by all vehicles. Only VOLVO, RENAULT, and American truck manufacturers implement the J1708 connector.

[[Image:FMX640 and 6PIN J1708 connection scheme v1.2.png]]

Trucks utilizes Deutsch 9-PIN connector, which is used to connect {{{model|FMX640}}} to J1708.

[[Image:FMX640 and 9PIN J1939 connection scheme v1.1.png]]

{|
| [[File:Alert.png|left|link=|50px]] || <b>NOTE: Most of the Volvo trucks need an J1708 connection to be able to receive fuel level data</b>
|}