Changes

no edit summary
Line 1: Line 1:  
==Introduction to the product==
 
==Introduction to the product==
DFM D S7 Differential Fuel Flow Meter connected to FMB using the Bluetooth interface.
+
DFM D S7 Differential and DFM S7 Fuel Flow Meter connected to FMB using the Bluetooth interface.
 
{|
 
{|
[[image:Diferencialnii-rashodomer-topliva-DFM-D.png|400px]]<br>
+
[[image:Diferencialnii-rashodomer-topliva-DFM-D.png|400px]]
 +
[[image:Scetchik-rashoda-topliva-DFM.png|200px]]
 +
<br>
 
|}
 
|}
   Line 8: Line 10:  
{|
 
{|
 
[[image:Compatibility Declaration, DFM D S7, EN.png|300px|Compatibility Declaration, DFM D S7]]
 
[[image:Compatibility Declaration, DFM D S7, EN.png|300px|Compatibility Declaration, DFM D S7]]
 +
[[File:Compatibility Declaration, DFM S7.png|300px|Compatibility Declaration, DFM S7]]
 
|}
 
|}
 
<br>
 
<br>
   −
==DFM D S7 Differential Fuel Flow Meter connection==
+
==DFM (D) S7 Differential Fuel Flow Meter connection==
 
Switch the DFM S7 flowmeter to the operating mode according to the operating instructions.<br>
 
Switch the DFM S7 flowmeter to the operating mode according to the operating instructions.<br>
To obtain the MAC address of the DFM S7 flowmeter, you need to transfer the sensor number from decimal to hexadecimal code.
+
To obtain the MAC address of the DFM (D) S7 flowmeter, you need to transfer the sensor number from decimal to hexadecimal code.
 
[[File:Dfm-d-s7 hex.png]]
 
[[File:Dfm-d-s7 hex.png]]
   Line 40: Line 43:  
[[File:Dut-e-s7 configurator4.png|800px|center]]
 
[[File:Dut-e-s7 configurator4.png|800px|center]]
 
<br>
 
<br>
In DFM S7, data is transferred in 4 PGNs (messages).<br>
+
In DFM D S7, data is transferred in 4 PGNs (messages).<br>
Since only 1 PGN can be configured in one connection (Connection 1), to receive all data from the fuel flow meter we use all four connections with the same MAC address (Connection 1, Connection 2, Connection3, Connection 4).<br>
+
In DFM S7, data is transferred in 3 PGNs (messages).<br>
 +
Since only 1 PGN can be configured in one connection (Connection 1), to receive all data from the fuel flow meter we use all four connections with the same MAC address (Connection 1, Connection 2, Connection3, Connection 4 (only DFM D S7)).<br>
 
Write down the MAC address of the sensor in the settings field and select the PGN settings:<br>
 
Write down the MAC address of the sensor in the settings field and select the PGN settings:<br>
 
[[File:Dfm-d-s7 configurator 5.png|800px|center]]<br>
 
[[File:Dfm-d-s7 configurator 5.png|800px|center]]<br>
   −
Data from the DFM S7 flowmeter are displayed in the configurator. Press the Low button to select the parameter to be sent to the server:<br>
+
Data from the DFM (D) S7 flowmeter are displayed in the configurator. Press the Low button to select the parameter to be sent to the server:<br>
 
[[File:Dfm-d-s7 configurator 10.png|800px|center]]
 
[[File:Dfm-d-s7 configurator 10.png|800px|center]]
 
<br>
 
<br>
Line 81: Line 85:  
BLE 3 Custom5 - Flowmeter Hours Of Operation. Cheating.<br>
 
BLE 3 Custom5 - Flowmeter Hours Of Operation. Cheating.<br>
   −
====PGN 63314 configuration====
+
====PGN 63314 configuration (only DFM D S7)====
 
[[File:Dfm-d-s7 configurator 9.png|800px|center]]
 
[[File:Dfm-d-s7 configurator 9.png|800px|center]]
 
Chamber fuel rate.<br>
 
Chamber fuel rate.<br>
Line 138: Line 142:  
| 18 || Flowmeter Hours Of Operation/Cheating || IO_474/const3600 || h
 
| 18 || Flowmeter Hours Of Operation/Cheating || IO_474/const3600 || h
 
|-
 
|-
| 19 || High Resolution Engine Total Used/Feed chamber || IO_334_dec*const0.001 || L
+
| 19 || High Resolution Engine Total Used/Feed chamber (only DFM D S7) || IO_334_dec*const0.001 || L
 
|-
 
|-
| 20 || High Resolution Engine Total Used/Reverse chamber || IO_475*const0.001 || L
+
| 20 || High Resolution Engine Total Used/Reverse chamber (only DFM D S7) || IO_475*const0.001 || L
 
|-
 
|-
| 21 || High Resolution Engine Total Used/Negative || IO_476*const0.001 || L
+
| 21 || High Resolution Engine Total Used/Negative (only DFM D S7) || IO_476*const0.001 || L
 
|-
 
|-
| 22 || High Resolution Engine Total Used/Feed chamber, Cheating || IO_477*const0.001 || L
+
| 22 || High Resolution Engine Total Used/Feed chamber, Cheating (only DFM D S7) || IO_477*const0.001 || L
 
|-
 
|-
| 23 || High Resolution Engine Total Used/Reverse chamber, Cheating|| IO_478*const0.001 || L
+
| 23 || High Resolution Engine Total Used/Reverse chamber, Cheating (only DFM D S7) || IO_478*const0.001 || L
 
|}
 
|}
 
<br>
 
<br>

Navigation menu