Changes

Line 38: Line 38:     
In that case, both “Buzzer ON Duration”, and “Buzzer OFF Duration” parameters would be ignored and only “Buzzer timeout” will be used for the buzzer.
 
In that case, both “Buzzer ON Duration”, and “Buzzer OFF Duration” parameters would be ignored and only “Buzzer timeout” will be used for the buzzer.
 
+
{| class="wikitable"
 
+
|+'''Table 2''' Buzzer scenario parameters
 
+
|'''Parameter  name'''
 +
|'''Min  value'''
 +
|'''Max  value'''
 +
|'''Default  value'''
 +
|'''Parameter  ID'''
 +
| colspan="2" |'''Description, possible values'''
 +
|-
 +
| rowspan="2" |Buzzer Scenario  Control
 +
| rowspan="2" |0
 +
| rowspan="2" |1
 +
| rowspan="2" |0
 +
| rowspan="2" |65800
 +
|Disable
 +
|0
 +
|-
 +
|Enable
 +
|1
 +
|-
 +
| rowspan="2" |Buzzer ON  Duration
 +
| rowspan="2" |0
 +
| rowspan="2" |65535
 +
| rowspan="2" |200
 +
| rowspan="2" |65608
 +
|Disables buzzer duration control
 +
|0
 +
|-
 +
|Time that buzzer will be on
 +
|1-65535
 +
|-
 +
| rowspan="2" |Buzzer OFF  Duration
 +
| rowspan="2" |0
 +
| rowspan="2" |65535
 +
| rowspan="2" |200
 +
| rowspan="2" |65609
 +
|Disables buzzer duration control
 +
|0
 +
|-
 +
|Time that buzzer will be off
 +
|1-65535
 +
|-
 +
| rowspan="5" |Buzzer control
 +
| rowspan="5" |0
 +
| rowspan="5" |4
 +
| rowspan="5" |0
 +
| rowspan="5" |65603
 +
|Disabled
 +
|0
 +
|-
 +
|DOUT 1
 +
|1
 +
|-
 +
|DOUT 2
 +
|2
 +
|-
 +
|Integrated
 +
|3
 +
|-
 +
|Reader
 +
|4
 +
|-
 +
| rowspan="2" |Buzzer control  timeout
 +
| rowspan="2" |0
 +
| rowspan="2" |3600
 +
| rowspan="2" |0
 +
| rowspan="2" |65604
 +
|Indefinite  timeout
 +
|0
 +
|-
 +
|Seconds
 +
|1-3600
 +
|-
 +
|Buzzer  volume control
 +
|0
 +
|100
 +
|100
 +
|65607
 +
|Only  visible when „Buzzer control“ is set to „Integrated“
 +
|0-100
 +
|}
 
[[Category:FMU126 Configuration]]
 