Changes

Line 62: Line 62:  
|-
 
|-
 
! 5  
 
! 5  
| Water jets || Water projected by a nozzle (6.3&nbspmm) against enclosure from any direction shall have no harmful effects. || Test duration: 1&nbsp;minute per square meter for at least 15 minutes<br /> Water volume: 12.5&nbsp;litres per minute Pressure: 30&nbsp;kPa at distance of 3&nbsp;m<br />  
+
| Water jets || Water projected by a nozzle (6.3&nbsp;mm) against enclosure from any direction shall have no harmful effects. || Test duration: 1&nbsp;minute per square meter for at least 15 minutes<br /> Water volume: 12.5&nbsp;litres per minute Pressure: 30&nbsp;kPa at distance of 3&nbsp;m<br />  
    
|-
 
|-
 
! 6  
 
! 6  
| Powerful water jets || Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield.<br />Test a) is conducted for 10&nbsp;minutes. Test b) is conducted (without shield) for 5&nbsp;minutes minimum. || Oscillating tube: Test duration: 10&nbsp;minutes, or spray nozzle (same as IPX3 spray nozzle with the shield removed)<br />  
+
| Powerful water jets || Water projected in powerful jets (12.5&nbsp;mm nozzle) against the enclosure from any direction shall have no harmful effects. || Test duration: 1&nbsp;minute per square meter for at least 3&nbsp;minutes<br />Water volume: 100&nbsp;litres per minute<br />
 +
Pressure: 100&nbsp;kPa at distance of 3&nbsp;m<br />
    
|-
 
|-
 
! 6k  
 
! 6k  
| Splashing of water || Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield.<br />Test a) is conducted for 10&nbsp;minutes. Test b) is conducted (without shield) for 5&nbsp;minutes minimum. || Oscillating tube: Test duration: 10&nbsp;minutes, or spray nozzle (same as IPX3 spray nozzle with the shield removed)<br />  
+
| Powerful water jets with increased pressure || Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield.<br />Test a) is conducted for 10&nbsp;minutes. Test b) is conducted (without shield) for 5&nbsp;minutes minimum. || Oscillating tube: Test duration: 10&nbsp;minutes, or spray nozzle (same as IPX3 spray nozzle with the shield removed)<br />  
 
|}
 
|}
0