Changes

Line 30: Line 30:  
For general comparison purpose, and to see what results can be achieved, you can refer to the following internal test results in different modes and sending frequencies:
 
For general comparison purpose, and to see what results can be achieved, you can refer to the following internal test results in different modes and sending frequencies:
   −
<br>
  −
  −
<table class="nd-othertables" style="width: 100%;">
  −
<tr>
  −
        <th style="width: 10%; text-align:center; vertical-align:middle; color: black">Mode:</th>
  −
        <th style="width: 20%; text-align:center; vertical-align:middle; color: black">Min Period (data saving frequency)</th>
  −
        <th style="width: 20%; text-align:center; vertical-align:middle; color: black">Send Period (data sending frequency)</th>
  −
        <th style="width: 15%; text-align:center; vertical-align:middle; color: black">Starting Voltage</th>
  −
        <th style="width: 15%; text-align:center; vertical-align:middle; color: black">Cut off Voltage</th>
  −
        <th style="width: 20%; text-align:center; vertical-align:middle; color: black">Time achieved</th>
  −
    </tr>
  −
        <tr>
  −
        <td style="vertical-align:middle">Operating</td>
  −
        <td>  10 seconds</td>
  −
        <td>  60 seconds</td>
  −
        <td>10,1V</td>
  −
        <td>8,3V</td>
  −
        <td>471 min (7 hours 51 minutes)</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="vertical-align:middle">Operating</td>
  −
        <td>60 seconds</td>
  −
        <td>60 seconds</td>
  −
        <td>10,2V</td>
  −
        <td>8,3V</td>
  −
        <td>546 min (9 hours 16 minutes)</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="vertical-align:middle">Deep Sleep</td>
  −
        <td>12 hours</td>
  −
        <td>12 hours</td>
  −
        <td>10,0V</td>
  −
        <td>8,2V</td>
  −
        <td>15120 min (252 hours 0 minutes)</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="vertical-align:middle">Online Deep Sleep</td>
  −
        <td>12 hours</td>
  −
        <td>12 hours</td>
  −
        <td>10,2V</td>
  −
        <td>8,6V</td>
  −
        <td>6480 min (108 hours 0 minutes)</td>
  −
    </tr>
  −
  −