Line 2: |
Line 2: |
| | product_name = FMB122 tracking device | | | product_name = FMB122 tracking device |
| }} | | }} |
| + | |
| + | ==2021.08.13: Base firmware update== |
| + | We would like to inform you about the base firmware update for FMB130 starting from August 13th, 2021. New production firmware version will be 03.27.07.Rev.00 |
| + | {| class="wikitable" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Change description |
| + | |- |
| + | | style="text-align: left; background: white;" |Change type |
| + | | colspan="2" style="text-align: left; background: white;" |Firmware update |
| + | |- |
| + | | rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description |
| + | | colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB130_firmware_errata |
| + | |- |
| + | | style="text-align: left; background: white;" |Old version: <br> FMB130 03.25.18.Rev.08 |
| + | | style="text-align: left; background: white;" |New version: <br> FMB130 03.27.07.Rev.00 |
| + | |- |
| + | | style="text-align: left; background: white;" |Change reasons |
| + | | colspan="2" style="text-align: left; background: white;" |FMB130 base firmware version update |
| + | |- |
| + | | style="text-align: left; background: white;" | Product release date |
| + | | colspan="2" style="text-align: left; background: white;" |2021 August |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Affected products |
| + | |- |
| + | | style="width: 221px; text-align: left; background: white;" |Model |
| + | | style="width: 448px; text-align: left; background: white;" |Affected order codes |
| + | | style="width: 448px; text-align: left; background: white;" | Order code changes |
| + | |- |
| + | | style="text-align: left; background: white;" |FMB130 |
| + | | style="text-align: left; background: white;" |FMB130******* order codes with base Firmware |
| + | | style="text-align: left; background: white;" |Update firmware |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Change impact |
| + | |- |
| + | | style="width: 221px; text-align: left; background: white;" |Risk assessment |
| + | | colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically |
| + | |- |
| + | | style="text-align: left; background: white;" |Suggested implementation plan |
| + | | colspan="2" style="text-align: left; background: white;" | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
| + | |- |
| + | |} |
| + | |
| ==2021.05.17: Base firmware update== | | ==2021.05.17: Base firmware update== |
| | | |