<font size="+2"><span style=color:#F49E21> 1. </span> Connecting wires </font>
 
<font size="+2"><span style=color:#F49E21> 1. </span> Connecting wires </font>
 
<font size="+1">
 
<font size="+1">
* Wires should be connected while module is not plugged in.
+
* Wires should be connected while the module is not plugged in.
* Wires should be fastened to the other wires or non-moving parts. Try to avoid heat emitting and moving objects near the wires.
+
* Wires should be fastened to stable wires or other non-moving parts. Any heat emitting and/or moving objects should be kept away from the wires.
* The connections should not have leftover exposed wires. If factory isolation was removed while connecting the wires, it should be reapplied.
+
* There should be no exposed wires. If factory isolation was removed while connecting the wires, the isolation material should be applied.
* If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied.
+
* If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied and the wires should not be loose.
 
* Wires cannot be connected to the board computers or control units.
 
* Wires cannot be connected to the board computers or control units.
 
</font>
 
</font>
 
<font size="+2"><span style=color:#F49E21> 2. </span> Connecting power source. </font>
 
<font size="+2"><span style=color:#F49E21> 2. </span> Connecting power source. </font>
 
<font size="+1">
 
<font size="+1">
* Be sure that after the car computer falls asleep, power is still available on the chosen wire. Depending on the car model, this may happen in 5 to 30 minutes period.
+
* Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on the car model, this may happen in 5 to 30 minutes period.
* When the module is connected, measure voltage again to make sure it did not decrease.
+
* When the module is connected, measure the voltage again to make sure it did not decrease.
 
* It is recommended to connect to the main power cable in the fuse box.
 
* It is recommended to connect to the main power cable in the fuse box.
* Use 3 A, 125 V external fuse.
+
* 3 A, 125 V external fuse shall be used.
 
</font>
 
</font>
 
<font size="+2"><span style=color:#F49E21> 3. </span> Connecting ignition wire. </font>
 
<font size="+2"><span style=color:#F49E21> 3. </span> Connecting ignition wire. </font>
 
<font size="+1">
 
<font size="+1">
* Be sure to check if it is a real ignition wire i.e. power does not disappear while starting the engine.
+
* Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
 
* Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
 
* Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
 
* Check if power is still available when you turn off any of vehicles devices.
 
* Check if power is still available when you turn off any of vehicles devices.
Line 220: Line 220:  
* Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
 
* Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
 
* If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
 
* If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
* For better contact scrub paint from the spot where loop is connected.
+
* For better contact scrub paint from the spot where loop is going to be connected.
 
</font>
 
</font>
   Line 228: Line 228:  
This message contains information on how to operate FMB120 safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!<br/>
 
This message contains information on how to operate FMB120 safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!<br/>
 
The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed range of voltage is +10-30 V DC.<br/>
 
The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed range of voltage is +10-30 V DC.<br/>
To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible, which show the status of device operation.<br/>
+
To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible. They show the status of device operation.<br/>
 
When connecting the 2x6 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.<br/>
 
When connecting the 2x6 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.<br/>
 
Before unmounting the device from the vehicle, the 2x6 connector must be disconnected.<br/>
 