Advanced Pulse Counter: Difference between revisions
no edit summary
No edit summary |
No edit summary |
||
Line 8: | Line 8: | ||
# Frequency is measured by counting pulses over time period (997 ms). Method is used for frequencies higher than 100 Hz. | # Frequency is measured by counting pulses over time period (997 ms). Method is used for frequencies higher than 100 Hz. | ||
# Frequency is measured by measuring time between pulses. Method is used for frequencies lower than 100 Hz. | # Frequency is measured by measuring time between pulses. Method is used for frequencies lower than 100 Hz. | ||
When 2kHz pulse counter is enabled, all other scenarios '''will ignore''' corresponding DIN state, except DIN1 which can be used to wakeup device from Deep Sleep. | |||
== Parameter values == | == Parameter values == | ||
Line 24: | Line 25: | ||
|50Hz | |50Hz | ||
|2kHz | |2kHz | ||
|- | |- | ||
|FMB110/FMB120/FMB130/FMB140 | |FMB110/FMB120/FMB130/FMB140 |