Changes

m
no edit summary
Line 1: Line 1: −
When no I/O element is enabled, AVL packet comes with GNSS information only. After enabling I/O element(s) AVL packet along with GNSS information contains current value(s) of enabled I/O elements.<br/>If the device is connected to configurator all current I/O values are displayed in ''Current Value'' column.<br/>''Priority'' field allows enabling I/O element(s) and setting them a priority so they are added to the data packet, which issent to the server. By default 12 I/O elements with low priority are enabled: ''Ignition'', ''Movement'', ''Data Mode'', ''GSM Signal'', ''Sleep Mode'', ''GNSS Status'', ''GNSS PDOP'', ''GNSS HDOP'', ''External Voltage'', ''Speed'', ''Battery Voltage'' and ''Battery Current''. ''Priority'' level (AVL packet priority) can be Low, High or Panic. All records made by FMB120 are regular. Regular packets are sent as low priority records. When low priority event is triggered, FMB120 makes an additional record with indication that the reason for the event was an I/O element change (depends on ''Operand'' configuration). When high priority is selected, module makes additional record with high priority flag and sends event packet immediately to the server through GPRS. Panic priority triggers same actions as high priority, but if GPRS fails, it sends an AVL packet using SMS data if SMS data sending is enabled and the number is given in ''SMS/Call Settings''.<br/>''High'' and ''Low'' levels define I/O value range. If I/O value enters or exits this range, FMB120 generates an event. ''Operand'' parameter defines when to generate event: On Exit, On Entrance, On Both, On Hysteresis and On Delta Change.<br/>When ''Event Only'' is selected, I/O element status value will be appended only to eventual records, otherwise, I/O element status value will appear in each AVL record.
+
When no I/O element is enabled, AVL packet comes with GNSS information only. After enabling I/O element(s) AVL packet along with GNSS information contains current value(s) of enabled I/O element(s).<br/>If the device is connected to configurator all current I/O values are displayed in ''Current Value'' column.<br/>''Priority'' field allows enabling I/O elements and setting them a priority so they are added to the data packet, which is sent to the server. By default 12 I/O elements with low priority are enabled: ''Ignition'', ''Movement'', ''Data Mode'', ''GSM Signal'', ''Sleep Mode'', ''GNSS Status'', ''GNSS PDOP'', ''GNSS HDOP'', ''External Voltage'', ''Speed'', ''Battery Voltage'' and ''Battery Current''. ''Priority'' level (AVL packet priority) can be Low, High or Panic. All records made by FMB120 are regular. Regular packets are sent as low priority records. When Low priority event is triggered, FMB120 makes an additional record with an indication that the event was caused by an I/O element change (depending on ''Operand'' configuration). When High priority is selected, module makes additional record with high priority flag and sends event packet immediately to the server using GPRS. Panic priority triggers same actions as high priority, but if GPRS fails, it sends an AVL packet using SMS data if SMS data sending is enabled and the number is provided in ''SMS/Call Settings''.<br/>''High'' and ''Low'' levels define I/O value range. If I/O value enters or exits this range, FMB120 generates an event. ''Operand'' parameter defines when to generate event: On Exit, On Entrance, On Both, On Hysteresis or On Delta Change.<br/>When ''Event Only'' is selected, I/O element status value will be appended only to eventual records, otherwise, I/O element status value will appear in each AVL record.
    
==Operands==
 
==Operands==
Line 14: Line 14:  
===Operand On Both===
 
===Operand On Both===
 
----
 
----
Record is generated by both (On Exit and On Entrance) operands logic at same time.
+
Record is generated by both On Exit and On Entrance operands' logic at same time.
 
[[Image:Fmb120_on_both.png|x150px|center]]
 
[[Image:Fmb120_on_both.png|x150px|center]]
    
===Operand Monitoring===
 
===Operand Monitoring===
 
----
 
----
No event at all. Values are recorded only when other triggers have worked.
+
No event at all. Values are recorded only when other triggers worked.
 
[[Image:Fmb120_operand_monitoring.png|x150px|center]]
 
[[Image:Fmb120_operand_monitoring.png|x150px|center]]
   Line 34: Line 34:  
===Operand On Delta Change===
 
===Operand On Delta Change===
 
----
 
----
Record is generated when input value changes and absolute value of change becomes equal or higher than the limit value.
+
Record is generated when input value changes and the absolute change becomes equal or higher than the limit value.
 
[[Image:Fmb120_on_delta_change.png|x150px|center]]
 
[[Image:Fmb120_on_delta_change.png|x150px|center]]
   Line 43: Line 43:     
==OBD II (Bluetooth) and LVCAN I/O elements==
 
==OBD II (Bluetooth) and LVCAN I/O elements==
''OBD II'' (Bluetooth) and ''LVCAN'' columns show I/O elements that can be obtained accordingly from OBD II Bluetooth dongle and LV-CAN200/ALL-CAN300 connected to FMB120 device. All I/O configuration is as described in [[FMB120 I/O settings|I/O settings]] section, except OBD II (Bluetooth) I/O element do not have an averaging constant parameter.<br/>Detailed description of LVCAN I/O element configuration is given in [[FMB120 CAN adapters|FMB120 with LV-CAN200 and ALL-CAN300 CAN adapters]].
+
''OBD II'' (Bluetooth) and ''LVCAN'' columns show I/O elements that can be obtained accordingly from OBD II Bluetooth dongle and LV-CAN200/ALL-CAN300 connected to FMB120 device. All I/O configuration is as described in [[FMB120 I/O settings|I/O settings]] section, except OBD II (Bluetooth) I/O element does not have an averaging constant parameter.<br/>Detailed description of LVCAN I/O element configuration is given in [[FMB120 CAN adapters|FMB120 with LV-CAN200 and ALL-CAN300 CAN adapters]].

Navigation menu