Changes

no edit summary
Line 53: Line 53:  
<br />
 
<br />
   −
After successful GPRS/SERVER settings configuration, FMB130 device will '''synchronize time''' and '''update records''' to '''the configured server'''. Time intervals and default I/O elements can be changed by using [[Teltonika Configurator]] or [[FMB130 Parameter list|SMS parameters]].<br />
+
After successful GPRS/SERVER settings configuration, FMC230 device will '''synchronize time''' and '''update records''' to '''the configured server'''. Time intervals and default I/O elements can be changed by using [[Teltonika Configurator]] or [[FMC230 Parameter list|SMS parameters]].<br />
 +
 
 +
<br>
 +
Possible ignition sources:
 +
 
 +
'''DIN 1''' (Digital Input 1) - if DIN1 is 1 - ignition is ON; if DIN1 value is 0 - ignition is OFF;<br>
 +
 
 +
'''Power Voltage''' - if voltage is between High Voltage Level and Low Voltage Level (below Ignition Settings options) - ignition is ON; if voltage is higher than High Voltage Level or lower than Low Voltage Level - ignition is OFF.<br>
 +
 
 +
'''Engine RPM''' - if RPM from OBD II or CAN is higher than 0 - ignition is ON; if RPM from OBD II or CAN is equal to 0 - ignition is OFF;<br>
 +
 
 +
'''Accelerometer''' - if movement sensor detects movement - ignition is ON; if movement is not detected - ignition is OFF;
 +
More than one ignition source can be selected at the same moment. When there are 2 or more sources selected, at least one condition has to be met to change Ignition status.<br>
 +
 
 +
'''DIN 3''' (Digital Input 3) - if DIN3 is 1 - ignition is ON; if DIN3 value is 0 - ignition is OFF;<br>
 +
 
 +
'''Example:''' DIN1 and Accelerometer are selected as the Ignition source. When the device detects movement, Ignition status will change to 1, regardless that DIN1 value is 0. Users can select movement start and movement stop delay time - those parameters are used when the accelerometer is selected as an ignition source. Ignition status is used in power management and the following functionalities: [https://wiki.teltonika-gps.com/view/FMC230_Features_settings#Eco.2FGreen_Drivingreen_Driving Eco/Green Driving], [https://wiki.teltonika-gps.com/view/FMC230_Accelerometer_Features_settings#Excessive_Idling Excessive Idling], Fuel Consumption, [[FMC230_Features_settings#Over_Speeding|Over Speeding]], [https://wiki.teltonika-gps.com/view/FMC230_Accelerometer_Features_settings#Towing_Detection Towing Detection] and [https://wiki.teltonika-gps.com/view/FMC230_Trip/Odometer_settings Trip].
 +
<br>
    
[[File:Ignition settings.gif|left|thumb|440x440px]]
 
[[File:Ignition settings.gif|left|thumb|440x440px]]
Line 60: Line 77:     
Ignition source settings:
 
Ignition source settings:
*<span style="background-color:#92c9d4;">101</span> - Ignition Source (1 - DIN1, 2 - Accelerometer, 3 - Power Voltage, 4 - Engine RPM, 5 - DIN3).
+
*<span style="background-color:#92c9d4;">101</span> - Ignition Source (1 - DIN1, 2 - Accelerometer, 3 - Power Voltage, 4 - Engine RPM, 5 - DIN3).<br>
 +
<span style="background-color:#92c9d4;">104</span> - Hight Voltage ( MIN - 0, MAX - 30000).<br>
 +
 
 +
<span style="background-color:#92c9d4;">105</span> - Low Voltage ( MIN - 0, MAX - 29999).
 
<br><br>
 
<br><br>
 
<br>
 
<br>