Changes

no edit summary
Line 1: Line 1: −
Data Acquisition modes are an essential part of FMB120 device, they are also highly configurable.<br/>Through configuration user defines how records will be saved and sent. There are three different modes: Home, Roaming and Unknown. All these modes with configured data acquisition and report frequencies depend on current GSM Operator defined in the Operator list (see section [[FMB120 GSM Operators settings|GSM Operators settings]]) and are switched when GSM operator changes (e.g. vehicle passes through a country border).<br/>If current GSM operator is defined as Home Operator, device will work in Home Data Acquisition mode, if current operator is defined as Roaming Operator, device will work in Roaming Data Acquisition mode, and if current operator code is not written in the Roaming Operator list, device will work in Unknown Acquisition mode.<br/>This functionality allows having different AVL records to acquire and send parameter values when object is moving or standing still. Vehicle moving or stop state is defined by Stop Detection Source parameter. There are 4 ways for FMB120 to switch between Vehicle on Stop and Vehicle Moving modes, please refer to the first table in [[FMB120 System settings|System settings]].<br/>FMB120 has 6 different modes. Operational logic is shown in the figure below.
+
Data Acquisition modes are an essential part of FMB120 device, they are also highly configurable.<br/>Through configuration user defines how records will be saved and sent. There are three different modes: Home, Roaming and Unknown. All these modes with configured data acquisition and report frequencies depend on current GSM Operator defined in the Operator list (see section [[FMB120 GSM Operators settings|GSM Operators settings]]) and are switched when GSM operator changes (e.g. vehicle passes through a country border).<br/>If current GSM operator is defined as Home Operator, device will work in Home Data Acquisition mode, if current operator is defined as Roaming Operator, device will work in Roaming Data Acquisition mode, and if current operator code is not written in the Roaming Operator list, device will work in Unknown mode.<br/>This functionality allows having different AVL records to acquire and send parameter values when object is moving or standing still. Vehicle moving or stop state is defined by Stop Detection Source parameter. There are 4 ways for FMB120 to switch between Vehicle on Stop and Vehicle Moving modes, please refer to the first table in [[FMB120 System settings|System settings]].<br/>FMB120 has 6 different modes. Operational logic is shown in the figure below.
    
{| class="wikitable" style="border-style: solid; border-width: 0px"
 
{| class="wikitable" style="border-style: solid; border-width: 0px"
0

edits

Navigation menu