Changes

7,163 bytes added ,  15:12, 6 June 2023
Created page with "thumb|400px|TeraCom TSH202 ==Introduction== TeraCom TSH202 is humidity and temperature sensors with a 1-Wire interface. The..."
[[File:1-wire-humidity-sensor-tsh202-gal-1-w.jpg|thumb|400px|TeraCom TSH202]]
==Introduction==

TeraCom TSH202 is humidity and temperature sensors with a 1-Wire interface. The device integrates basic elements plus signals processing, and provides a fully calibrated digital output. A unique capacitive element is used for measuring relative humidity while the temperature is measured by a band gap sensor. Both sensors are seamlessly coupled to a 12-bit analog to digital converter. This results in superior signal quality and fast response time.

==Applications==

*Server room and data centers monitoring.
*Environmental quality monitoring and assessment.
*Humidity and temperature monitoring in building management systems.
*Humidity and temperature monitoring for mobile operator facilities, vineyards, greenhouses, etc.

==Technical parameters==

{| class="wikitable"
|+
! style="width:50%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;" |NAME
! style="border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;" |DESCRIPTION
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |Interface
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |1-Wire Interface
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |Wiring
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |<span style="color:#D5D5D5"><b>White</b></span> = 1-wire signal, <span style="color:Red"><b>Red</b></span> = 1-wire power, <span style="color:Black"><b>Black</b></span> = Ground
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |'''*''' Operating temperature
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |-20 ºC to +60 ºC
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |'''*''' Operating humidity
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |10 to 90%RH
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |Tolerance typ.
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |±3.0 %RH (20 to 80 %RH), ±0.4 °C (-10 to +60°C)
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |Tolerance max.
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |±5.0 %RH (10 to 90) %RH, ±1.0 °C (-20 to +60°C)
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |Power supply/consumption
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |4.0 to 5.5 VDC, 5 mA
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |Dimensions
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |45 x 16 x 10
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |Cable length
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |1 m
|-
|}

'''<nowiki>*</nowiki>''' Recommended operating range is 20% to 80% RH (non-condensing) over -10°C to +60°C.

Prolonged operation beyond these ranges may result in a shift of sensor reading, with slow recovery time.

==Installation==

*TSH202 will be connected with FM devices via 1-wire interface.
*To connect the 1-wire TSH202 sensor you have to make sure to connect 3 PINs of the sensor to the PINs of your device correctly.

[[File:TSH202 Scheme.PNG|frameless|800x420px]] [[File:FMB120-2x6 socket pinout.png|thumb|400px|FMB120-2x6 socket pinout]]
[[File:FMC130-2x6 socket pinout.png|thumb|400px|FMC130-2x6 socket pinout]]




==Connections==

We tested TSH202 sensor with FMB120 & FMC130 devices and connections will be as per following sequence.


{| class="wikitable"
|+
! style="width:20%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;" |TSH202 wire color
! style="width:40%; border: 1px solid white; border-bottom: 2px solid #0054A6; background: white; color: #0054A6; text-align: left;" |Connections
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |<span style="color:red"><b>Red</b></span>
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |+VDD (+4.0 to +5.5V) 1-wire power of FM device
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |<span style="color:#D5D5D5"><b>White</b></span>
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |1-wire signal of FM device
|-
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |<span style="color:black"><b>Black</b></span>
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |Ground of FM device
|-
|}





==Configuration==


#Use the tested '''Firmware ver.03.27.13.Rev.480.e'''
#Use '''Teltonika.Configurator_1.7.30_E.THS202_R.4'''

===With FMB120:===

[[File:TSH202-FMB120.mp4|none|thumb|1920x1080px]]

===With FMC130:===

[[File:TSH202-FMC130.mp4|none|thumb|1920x1080px]]

'''''<span style="color:blue"><b><nowiki>*</nowiki>''' The used Firmware is tested with '''TSH202v3 models and above'''.</b></span>''

==Demonstration in Flespi platform==
Flespi: Open Flespi application → Select Device → Select Logs & Messages → Select the record interval → Tap to see all information.

===With FMB120:===

[[File:FMB120 TSH202-server.mp4|none|thumb|1920x1080px]]

===With FMC130:===

[[File:FMC130 TSH202-server.mp4|none|thumb|1920x1080px]]

==Downloads==
'''Manual & Documentation'''<br>

[[File:pdf_icon.png|32px|link=]]
[[Media:Tsh202v3-1-wire-humidity-temperature-sensor-brochure-r1.10.pdf|1-Wire humidity and temperature sensor TSH202 brochure(v1.10)]]


[[Category:Accessories]]