Advanced Pulse Counter: Difference between revisions
no edit summary
No edit summary |
No edit summary |
||
Line 446: | Line 446: | ||
Also, devices that’s support 2kHz on DIN1 (see Table 1) have same limitations as DIN2, but also minimum voltage provided to DIN1 by pulse should be 7.5V or grater. Lower than 7.5V pulses add pulse rise time. For example, at 3.6V pulse rise time is ~500us comparing to 7.5V at 60us (FMB920). Pulse counting might work at these low voltages with low frequency but it is not reliable. | Also, devices that’s support 2kHz on DIN1 (see Table 1) have same limitations as DIN2, but also minimum voltage provided to DIN1 by pulse should be 7.5V or grater. Lower than 7.5V pulses add pulse rise time. For example, at 3.6V pulse rise time is ~500us comparing to 7.5V at 60us (FMB920). Pulse counting might work at these low voltages with low frequency but it is not reliable. | ||
{| class="wikitable" | |||
!'''Duty Cycle, % =20''' | |||
! colspan="6" |'''DIN1''' | |||
! rowspan="3" |'''Notes''' | |||
|- | |||
! rowspan="2" |'''U, V''' | |||
! colspan="6" |'''Frequency , Hz''' | |||
|- | |||
|30 | |||
|50 | |||
|100 | |||
|500 | |||
|1000 | |||
|2000 | |||
|- | |||
|7.5 | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>-</nowiki> | |||
|Min Duty Cycle at 2kHz is ~25% | |||
|- | |||
|8 | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>-</nowiki> | |||
|Min Duty Cycle at 2kHz is ~25% | |||
|- | |||
|10 | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>-</nowiki> | |||
|Min Duty Cycle at 2kHz is ~25% | |||
|- | |||
! colspan="8" | | |||
|- | |||
!'''Duty Cycle, % =50''' | |||
! colspan="6" |'''DIN1''' | |||
! rowspan="3" |'''Notes''' | |||
|- | |||
! rowspan="2" |'''U, V''' | |||
! colspan="6" |'''Frequency , Hz''' | |||
|- | |||
|30 | |||
|50 | |||
|100 | |||
|500 | |||
|1000 | |||
|2000 | |||
|- | |||
|7.5 | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
| | |||
|- | |||
|8 | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
| | |||
|- | |||
|10 | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
| | |||
|- | |||
! colspan="8" | | |||
|- | |||
!'''Duty Cycle, % =80''' | |||
! colspan="6" |'''DIN1''' | |||
! rowspan="3" |'''Notes''' | |||
|- | |||
! rowspan="2" |'''U, V''' | |||
! colspan="6" |'''Frequency , Hz''' | |||
|- | |||
|30 | |||
|50 | |||
|100 | |||
|500 | |||
|1000 | |||
|2000 | |||
|- | |||
|7.5 | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>-</nowiki> | |||
|Max Duty Cycle at 2kHz is ~70% | |||
|- | |||
|8 | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>-</nowiki> | |||
|Max Duty Cycle at 2kHz is ~70% | |||
|- | |||
|10 | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>+</nowiki> | |||
|<nowiki>-</nowiki> | |||
|Max Duty Cycle at 2kHz is ~70% | |||
|} | |||
==Advanced pulse counter parameter in configurator== | ==Advanced pulse counter parameter in configurator== |