Line 21: |
Line 21: |
| |- | | |- |
| | style="text-align: left; background: #F6F6FB;" | 3 | | | style="text-align: left; background: #F6F6FB;" | 3 |
− | | style="text-align: left; background: #000000;" | <span style=color:#FFFFFF>'''AIN 2 / DIN 3'''</span> | + | | style="text-align: left; background: #000000;" | <span style=color:#FFFFFF>'''RS232-RX'''</span> |
− | | style="text-align: left; background: #F6F6FB;" | Analog input, channel 2. Input range: 0-30 V DC / Digital input, channel 3. | + | | style="text-align: left; background: #F6F6FB;" | Input for data reception through RS-232. |
| |- | | |- |
| | style="text-align: left; background: #F6F6FB;" | 4 | | | style="text-align: left; background: #F6F6FB;" | 4 |
− | | style="text-align: left; background: #000000;" | '''<span style=color:#00FF00>D</span><span style=color:#FFFFFF>IN</span><span style=color:#00FF00> 2</span>''' | + | | style="text-align: left; background: #000000;" | '''<span style=color:#00FF00>R</span><span style=color:#FFFFFF>S2</span><span style=color:#00FF00>32</span><span style=color:#FFFFFF>-T</span><span style=color:#00FF00>X</span>''' |
− | | style="text-align: left; background: #F6F6FB;" | Digital input, channel 2. | + | | style="text-align: left; background: #F6F6FB;" | Output for data transmission through RS-232. |
| |- | | |- |
| | style="text-align: left; background: #F6F6FB;" | 5 | | | style="text-align: left; background: #F6F6FB;" | 5 |
Line 45: |
Line 45: |
| |-FFA500 | | |-FFA500 |
| | style="text-align: left; background: #F6F6FB;" | 9 | | | style="text-align: left; background: #F6F6FB;" | 9 |
− | | style="text-align: left; background: #000000;" | <span style=color:#800080>'''OUT 2'''</span> | + | | style="text-align: left; background: #000000;" | <span style=color:#800080>'''RS485-A'''</span> |
− | | style="text-align: left; background: #F6F6FB;" | Digital output, channel 2. Open collector output. Max. 3,3 A DC. | + | | style="text-align: left; background: #F6F6FB;" | Signal wire A for RS-485. |
| |- | | |- |
| | style="text-align: left; background: #F6F6FB;" | 10 | | | style="text-align: left; background: #F6F6FB;" | 10 |
− | | style="text-align: left; background: #000000;" | <span style=color:#0000FF>'''1WIRE POWER'''</span> | + | | style="text-align: left; background: #000000;" | <span style=color:#0000FF>'''RS485-B'''</span> |
− | | style="text-align: left; background: #F6F6FB;" | +3,8 V output for 1–Wire devices. | + | | style="text-align: left; background: #F6F6FB;" | Signal wire B for RS-485. |
| |- | | |- |
| | style="text-align: left; background: #F6F6FB;" | 11 | | | style="text-align: left; background: #F6F6FB;" | 11 |