Line 31: |
Line 31: |
| * Cold environment (+3°C) : <6.5 V<br> | | * Cold environment (+3°C) : <6.5 V<br> |
| * Very cold environment (~-22°C) : <6.3 V<br> | | * Very cold environment (~-22°C) : <6.3 V<br> |
− | <br>
| + | |
| {| class="main-table" style="background: #E7F1FE; color: black;" | | {| class="main-table" style="background: #E7F1FE; color: black;" |
| {| style="width: 800px;height: 60px; text-align: left; border: 1 px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | | {| style="width: 800px;height: 60px; text-align: left; border: 1 px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" |
Line 38: |
Line 38: |
| These are examples and recommendations of the low battery alarm concept only. <br>Actual battery discharge curves may differ in various conditions. | | These are examples and recommendations of the low battery alarm concept only. <br>Actual battery discharge curves may differ in various conditions. |
| |} | | |} |
− | <br>
| + | |
| ===Low Voltage Record=== | | ===Low Voltage Record=== |
| To identify and get a dedicated record telling that the voltage threshold has been exceeded, follow below instructions. <br> | | To identify and get a dedicated record telling that the voltage threshold has been exceeded, follow below instructions. <br> |
Line 53: |
Line 53: |
| <br> | | <br> |
| Above can also be configured by sending an SMS/GPRS command to a device that has already been deployed in the field. <br> | | Above can also be configured by sending an SMS/GPRS command to a device that has already been deployed in the field. <br> |
− | <code>setparam 50120:1;50123:0;50122:6600;50124:1;50121:1</code><br><br> | + | <code>setparam 50120:1;50123:0;50122:6600;50124:1;50121:1</code><br> |
| {| class="main-table" style="background: #E7F1FE; color: black;" | | {| class="main-table" style="background: #E7F1FE; color: black;" |
| {| style="width: 800px;height: 60px; text-align: left; border: 1 px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | | {| style="width: 800px;height: 60px; text-align: left; border: 1 px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" |
Line 59: |
Line 59: |
| || '''Please note:'''<br> | | || '''Please note:'''<br> |
| Device will only receive SMS/GPRS command when it wakes up for periodic or scheduled record. | | Device will only receive SMS/GPRS command when it wakes up for periodic or scheduled record. |
− | |}<br><br> | + | |}<br> |
| Every time device wakes up to send a new record battery voltage is measured. If the battery voltage is lower than configured threshold (6.6 V in this example), an Event Record will be generated and sent to the server. This record will have event number <b>"67"</b> indicating low voltage. <br> | | Every time device wakes up to send a new record battery voltage is measured. If the battery voltage is lower than configured threshold (6.6 V in this example), an Event Record will be generated and sent to the server. This record will have event number <b>"67"</b> indicating low voltage. <br> |
| Example record content:<br> | | Example record content:<br> |