From Teltonika Telematics Wiki
CAUTION! Both firmwares (Modem and BlueNRG) must be flashed into device. Failing so can lead to unexpected device behavior and rapid battery discharge.
TAT100 BlueNRG & Modem FIRMWARE UPDATE GUIDE
TATXYZ FIRMWARE UPDATE GUIDE
Download Firmware and Configurator from STABLE FIRMWARE or SHORT-TERM FIRMWARE pages.
After device connection to Configurator:
1) Select Update firmware;
2) Select to flash Firmware(*.e.XIM) file;
3) Click on file;
4) And select Open.
Wait until the device will upload the firmware.
When parameters successfully loaded:
1) Select Update firmware;
2) Select to flash BlueNRG firmware(*.bin);
3) Click on file;
4) And select Open.
Backup/BLE support Feature Firmware
SHORT-TERM FIRMWARE
FIRMWARE VERSION:
Not Available
CONFIGURATOR VERSION:
Not Available
BlueNRG VERSION:
Not Available
RELEASE DATE:
Not Available
On request via Teltonika HelpDesk
TAT100 Hardware version identification
If Serial Number [S/N] is greater than 1122473261 , then device version: TAT100 HW: 62 .
If Serial Number [S/N] is less than 1122473261 , then device version: TAT100 HW: 31 .
ORDERS AFTER 2022-03-17 WILL BE WITH TAT100 HARDWARE: 62
CAUTION!
When updating firmware via FOTA WEB, pay attention to notice above.
NOTE!
THERE IS NO SHORT TERM FIRMWARE AVAILABLE. PLEASE USE THE STABLE VERSION.
CHANGELOG
VERSION
RELEASE DATE
CONFIGURATOR CHANGES
FIRMWARE CHANGES
KNOWN ISSUES
N/A
N/A
N/A
N/A
N/A
VERSION
RELEASE DATE
CONFIGURATOR CHANGES
FIRMWARE CHANGES
KNOWN ISSUES
Firmware version: 55.00.16.Rev.543* BlueNRG version: 10.3.12 for TAT100 HW ver.: 31
0.3.12 for TAT100 HW ver.: 62 Configurator version: 1.7.16_E.TAT100.R23 RELEASE*was approved as STABLE
2022.08.08
Updated Teltonika Configurator version to set Central device default IMEI to 300000000000000
SMS command created for getting device statistics
Protection from writing other devices FW
Added condition to prevent modem waking up at midnight if scheduler is configured
Added reconfiguration mechanism that lets FW work with / without SMPS filterMissing
Fixed issue of missing 4th sensor's data with Monitoring operand
Fixed too frequent / unnecessary scans with all sensors configured as monitoring
Fixed sensors scan starting with monitoring operand when Backup tracker is configured
Backup tracker scan not starting right after
Time synchronization every 24 hours
Fixed LBS data sending issue
New AVL ID 20015 for Modem UpTime (in seconds)
Added response sending if recovery command is sent through GPRS
The next periodic record after Recovery mode deactivation being sent with AVL ID 20012 - fixed
Reduced EQ Core update frequency
Fixed battery consumption issue when GSM is jammed.
LED status changed from constant on to blinking mode to save the battery
Firmware version: 55.00.16.Rev.531 BlueNRG version: 10.3.6 for TAT100 HW ver.: 31
0.3.6 for TAT100 HW ver.: 62 Configurator version: 1.7.16_R.TAT100.R5
2022.04.14
Added Recovery mode option
Added I/O element of Recovery Mode
Added more options of movement sensitivity threshold [50-1000mG]
Added Recovery mode feature
Implemented Recovery mode activation from the Backup tracking alarm
Added EYE sensors support
Fixed Minor bugs regarding the sensors
Fixed Short period Recovery Mode records
Extended Backup Tracker: Central device IMEI range
Backup tracker: Scanning logic has been changed, scan duration is not configurable anymore, it is up to 60 seconds by default now.
Implemented Record timestamp shift feature
Sometimes sensor records are randomly generated when using Backup Tracking with the USB cable plugged in.
Only 2 sensors are working correctly with Monitoring Operand, values from the 3rd and 4th sensor may not be received.
Firmware version: 55.00.16.Rev.522 BlueNRG version: 10.2.21.Rev.01 Configurator version: 1.7.16_R.TAT100.R2-BACKUP
2021.12.21
Backup firmware:
Changed required packets amount in backup tracker scenario and minimal scan duration
Fixed backup tracker alarm not triggering just before wakeup
Fixed backup tracker not detecting enough packets during BLE scan
Periodic records do not affect backup tracker alarm record generation
Sometimes Periodic
/Schedule
record overwrites backup alarm record if both records are created at a same time.
Possible workaround would be to disable periodical records:
Tracking → Tracking Mode: None
Firmware version: 55.00.16.Rev.522 BlueNRG version: 10.2.21.Rev.01 Configurator version: 1.7.16_R.TAT100.R2-BLE
2021.12.21
BLE firmware:
Fixed BLE sensor records with wrong event ID being sent
Fixed BLE sensor record duplicates with On change
operand
Fixed BLE sensor On Exit
record not generating when switching to sleep mode
Fixed Custom1
sensor data in SMS being sent as NaN (empty)
Fixed duplicate BLE sensor data after waking up
Firmware version: 55.00.15.Rev.519 BlueNRG version: 10.2.14 Configurator version: 1.7.16_R.TAT100.R2-BACKUP
2021.10.19
Fixed fake movement detection on startup
Fixed problem when the device is stuck in On Stop tracking mode after reconfiguration
Added Power-On reason data and fixed version changes to device statistics
Fixed Backup tracker issue where the alarm mode is not immediately activated when the central device disappears
Fixed empty GSM I/O elements
Fixed an issue where UTC is added after each reconfiguration
Added record printing to Dump log
LBS data is not included in records if GNSS fix was caught
Fixed NTP timesync failure if offset is zero
Improved record creation (wake up from sleep) during Backup tracker alarms
Improved GNSS module control with Static Navigation
and LBS
Added prevention from inappropriate record generation if the battery is low (HW watchdog)
Added statistic element for USB connected uptime
Added timestamp to BlueNRG serial prints
Minor improvement for BlueNRG firmware update via configurator
Added filter for LBS
cell_id duplicates
Improved Bluetooth® sensor record creation with 'On Change'
operand
Added Bluetooth® sensor support
Added condition to skip LBS data update if location source is only GNSS
Increased retries of AT+# command in order to avoid empty LBS data from modem
Changed Open link timeout
to 15s
Fixed an issue where the tracking mode would change from the scheduler to periodic
Improved logic for multiple FOTA Web
tasks update in the same connection
Implemented rule for additional connection to FOTA Web
after baseband firmware update
Added accelerometer version information inside '.info' serial command
Fixed an issue with battery voltage I/O element
when record saving is overlapping with a firmware update
Fixed Scheduler
record sending at midnight
Fixed missed LBS values inside I/O elements
Fixed an issue when GNSS speed is not zero while the device is in a stationary position
General minor improvements