TAT140 Parameter list

From Teltonika Telematics Wiki
Main Page > Autonomous Trackers > TAT140 > TAT140 Manual > TAT140 Parameter list

System parameters

System Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
109 Uint8 10 1 15 0 – Undefined GNSS source
1 – Beidou only
2 – Glonass only
3 – Glonass and Beidou not allowed
4 – Galileo only
5 – Galileo and Beidou
6 – Galileo and Glonass
7 – Galileo, Glonass and Beidou not allowed
8 – Gps only
9 – Gps and Beidou
10 – Gps and Glonass
11 – Gps, Glonass and Beidou not allowed
12 – Gps and Galileo
13 – Gps, Galileo and Beidou
14 – Gps, Galileo and Glonass
15 – Gps, Galileo, Glonass and Beidou and not allowed
187 Uint8 5 0 30 Seconds Coordinate Acquisition Timeout (s)
106 Uint16 1 0 1 0 - Disable Static Navigation
1 - Enable
902 Char "avl1.teltonika.lt" 0 55 String NTP server 1
903 Char "pool.ntp.org" 0 55 String NTP server 2

GPRS

GPRS Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 Uint8 1 0 1 0 – Disable GPRS context
1 – Enable
2001 Char "" 0 32 String APN
2002 Char "" 0 32 String APN username
2003 Char "" 0 32 String APN password
2016 Uint8 0 0 1 0 - Normal (PAP) -
1 - Secured (CHAP)

Server Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2004 Char "" 0 55 String Domain
2005 Uint16 0 0 65535 Number Port
2006 Uint8 0 0 1 0 – TCP Protocol
1 – UDP

Records Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1002 Uint8 1 0 1 0 – Newest Sort by
1 – Oldest
1004 Uint8 1 0 1 0 – TCP/IP ACK Type
1 – AVL

FOTA WEB Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13003 Uint8 1 0 1 0 - Disable FOTA WEB Status
1 – Enable
13000 Char fota.teltonika.lt 0 55 String FOTA WEB Domain
13001 Uint16 5000 0 65535 Number FOTA WEB Port

SMS/Call Settings

SMS Commands

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3003 Char "" 0 5 String Login
3004 Char "" 0 5 String Password

GSM Operations

Common settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2018 Uint8 0 0 1 0 – Disable Ban List Control
1 – Enable

Tracking

Tracking Scenarios

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
184 Uint8 2 0 2 0 – Backup Tracker Tracking mode
1 – Periodic
2 – Scheduler
3006 Uint8 0 -720 840 -720 – UTC-12:00 UTC Time Zone
-690 – UTC-11:30
-660 – UTC-11:00
-630 – UTC-10:30
-600 – UTC-10:00
-570 – UTC-09:30
-540 – UTC-09:00
-510 – UTC-08:30
-480 – UTC-08:00
-450 – UTC-07:30
-420 – UTC-07:00
-390 – UTC-06:30
-360 – UTC-06:00
-330 – UTC-05:30
-300 – UTC-05:00
-270 – UTC-04:30
-240 – UTC-04:00
-210 – UTC-03:30
-180 – UTC-03:00
-150 – UTC-02:30
-120 – UTC-02:00
-90 – UTC-01:30
-60 – UTC-01:00
-30 – UTC-00:30
0 – UTC+00:00
30 – UTC+00:30
60 – UTC+01:00
90 – UTC+01:30
120 – UTC+02:00
150 – UTC+02:30
180 – UTC+03:00
210 – UTC+03:30
240 – UTC+04:00
270 – UTC+04:30
300 – UTC+05:00
330 – UTC+05:30
360 – UTC+06:00
390 – UTC+06:30
420 – UTC+07:00
450 – UTC+07:30
480 – UTC+08:00
510 – UTC+08:30
540 – UTC+09:00
570 – UTC+09:30
600 – UTC+10:00
630 – UTC+10:30
660 – UTC+11:00
690 – UTC+11:30
720 – UTC+12:00
750 – UTC+12:30
780 – UTC+13:00
810 – UTC+13:30
840 – UTC+14:00
236 Uint8 1 0 1 0 – Off On Stop Periodic Tracking
1 – On
237 Uint8 0 0 1 0 – Disable On Stop Event Record
1 – Enable
185 Uint32_t 28800 360 604800 Seconds On Stop (s)
238 Uint8 1 0 1 0 – Off On Move Periodic Tracking
1 – On
239 Uint8 0 0 1 0 – Disable On Move Event Record
1 – Enable
186 Uint32_t 28800 360 604800 Seconds On Moving (s)
234 Uint32_t 300 300 36000 Seconds On Stop Detection Time
235 Uint32_t 20 5 600 Seconds On Move Detection Time
196 Uint8 1 1 10 1 – None Recovery Mode
2 – Tamper
4 – Lost BLE sensor
6 – Tamper & Lost BLE sensor
8 – Backup Tracker
10 – Tamper & Backup Tracker
197 Uint8 180 30 28800 Seconds Period(s)

Scheduler

Parameter ID Parameter Type Default value Value range Value Parameter name Day Of The Week
Min Max
2600 Uint8 0 0 1 0 – OFF Day Of The Week Monday
1 – ON
2500 Uint8 0 0 5 0 – 1 Records per day
1 – 2
2 – 3
3 – 4
4 – 5
5 – 6
2510 Uint8 1200 0000 2359 time 1st Record
2511 Uint8 1200 0000 2359 time 2nd Record
2512 Uint8 1200 0000 2359 time 3rd Record
2513 Uint8 1200 0000 2359 time 4th Record
2514 Uint8 1200 0000 2359 time 5th Record
2515 Uint8 1200 0000 2359 time 6th Record

IMPORTANT: 4 digits representing time in 24 hours format. For example: 1826 will be 18h 26 min. Note, that value can not be an invalid time like 1899.


Similarly to a group defined in the upper table:

Day Of The Week Parameter ID
Day Records per day 1st 2nd 3rd 4th 5th 6th
Monday 2600 2500 2510 2511 2512 2513 2514 2515
Tuesday 2601 2501 2520 2521 2522 2523 2524 2525
Wednesday 2602 2502 2530 2531 2532 2533 2534 2535
Thursday 2603 2503 2540 2541 2542 2543 2544 2545
Friday 2604 2504 2550 2551 2552 2553 2554 2555
Saturday 2605 2505 2560 2561 2562 2563 2564 2565
Sunday 2606 2506 2570 2571 2572 2573 2574 2575

I/O

Parameter ID Parameter Type Default value Value range Value parameter Input Name
Min Max
50020 Uint8 0 0 3 0 – None Priority Data Mode
1 – Low
2 – High
3 – Panic
50023 Uint8 0 0 0 - Low Level
50022 Uint8 0 0 5 - High Level
50024 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50021 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7002 Uint8 0 0 10 Predefined Number Send SMS To
8002 String Data Mode 0 160 Predefined Number SMS Text
50030 Uint8 1 0 3 0 – None Priority GSM Signal
1 – Low
2 – High
3 – Panic
50033 Uint8 0 0 0 - Low Level
50032 Uint8 0 0 5 - High Level
50034 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50031 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50035 Uint16 7 0 65535 - Average Const
7003 Uint8 0 0 10 Predefined Number Send SMS To
8003 String GSM Signal 0 160 Predefined Number SMS Text
50050 Uint8 1 0 3 0 – None Priority GNSS Status
1 – Low
2 – High
3 – Panic
50053 Uint8 0 0 0 - Low Level
50052 Uint8 0 0 5 - High Level
50054 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50051 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7005 Uint8 0 0 10 Predefined Number Send SMS To
8005 String GNSS Power 0 160 Predefined Number SMS Text
50060 Uint8 1 0 3 0 – None Priority GNSS PDOP
1 – Low
2 – High
3 – Panic
50063 Uint8 0 0 0 - Low Level
50062 Uint8 0 0 1000 - High Level
50064 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50061 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50065 Uint16 10 0 65535 - Average Const
7006 Uint8 0 0 10 Predefined Number Send SMS To
8006 String GNSS PDOP 0 160 Predefined Number SMS Text
50070 Uint8 1 0 3 0 – None Priority GNSS HDOP
1 – Low
2 – High
3 – Panic
50073 Uint8 0 0 0 - Low Level
50072 Uint8 0 0 1000 - High Level
50074 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50071 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50075 Uint16 10 0 65535 - Average Const
7007 Uint8 0 0 10 Predefined Number Send SMS To
8007 String GNSS HDOP 0 160 Predefined Number SMS Text
50090 Uint8 1 0 3 0 – None Priority Speed
1 – Low
2 – High
3 – Panic
50093 Uint8 0 0 0 Km/h Low Level
50092 Uint8 0 0 300 Km/h High Level
50094 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50091 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50095 Uint16 1 0 65535 - Average Const
7009 Uint8 0 0 10 Predefined Number Send SMS To
8009 String Speed 0 160 Predefined Number SMS Text
50100 Uint8 0 0 3 0 – None Priority GSM Cell ID
1 – Low
2 – High
3 – Panic
50103 Uint8 0 0 0 - Low Level
50102 Uint8 0 0 999999 - High Level
50104 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50101 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7010 Uint8 0 0 10 Predefined Number Send SMS To
8010 String GSM Cell ID 0 160 Predefined Number SMS Text
50110 Uint8 0 0 3 0 – None Priority GSM Area Code
1 – Low
2 – High
3 – Panic
50113 Uint8 0 0 0 - Low Level
50112 Uint8 0 0 999999 - High Level
50114 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50111 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7011 Uint8 0 0 10 Predefined Number Send SMS To
8011 String GSM Area Code 0 160 Predefined Number SMS Text
50120 Uint8 1 0 3 0 – None Priority Battery Voltage
1 – Low
2 – High
3 – Panic
50123 Uint8 0 0 5000/11000 (LiPo/NiMh) mV Low Level
50122 Uint8 0 0 5000/11000 (LiPo/NiMh) mV High Level
50124 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50121 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50125 Uint16 10 0 65535 - Average Const
7012 Uint8 0 0 10 Predefined Number Send SMS To
8012 String Battery Voltage 0 160 Predefined Number SMS Text
50140 Uint8 1 0 3 0 – None Priority Active GSM Operator
1 – Low
2 – High
3 – Panic
50143 Uint8 0 0 0 - Low Level
50142 Uint8 0 0 9999999 - High Level
50144 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50141 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7014 Uint8 0 0 10 Predefined Number Send SMS To
8014 String Active GSM Operator 0 160 Predefined Number SMS Text
50250 Uint8 0 0 3 0 – None Priority ICCID
1 – Low
2 – High
3 – Panic
50254 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50251 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7069 Uint8 0 0 10 Predefined Number Send SMS To
8069 String ICCID Value 0 160 Predefined Number SMS Text
51050 Uint8 0 0 3 0 – None Priority Instant Movement
1 – Low
2 – High
3 – Panic
51053 Uint8 0 0 0 - Low Level
51052 Uint8 0 0 1 - High Level
51054 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
51051 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
51055 Uint16 10 0 65535 - Average Const
7286 Uint8 0 0 10 Predefined Number Send SMS To
8286 String Instant Movement 0 160 Predefined Number SMS Text
51730 Uint8 0 0 3 0 – None Priority Coordinates ISO6709
1 – Low
2 – High
3 – Panic
51734 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
51731 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7376 Uint8 0 0 10 Predefined Number Send SMS To
8376 String ISO6709 Coordinates 0 160 Predefined Number SMS Text
50010 Uint8 1 0 3 0 – None Priority Movement
1 – Low
2 – High
3 – Panic
50013 Uint8 0 0 0 - Low Level
50012 Uint8 0 0 1 - High Level
50014 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50011 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50015 Uint16 10 0 65535 - Average Const
7001 Uint8 0 0 10 Predefined Number Send SMS To
8001 String Movement 0 160 Predefined Number SMS Text