TAT240 AVL ID List
To search for compatible products, Expand all content
Permanent I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
240 | Movement | 1 | Unsigned | 0 | 1 | - | - |
0 – Movement Off |
Permanent I/O elements | |
80 | Data Mode | 1 | Unsigned | 0 | 5 | - | - |
0 – Home On Stop |
Permanent I/O elements | |
21 | GSM Signal | 1 | Unsigned | 0 | 5 | - | - | Value in scale 1-5 | Permanent I/O elements | |
69 | GNSS Status | 1 | Unsigned | 0 | 3 | - | - |
0 - GNSS OFF |
Permanent I/O elements | |
181 | GNSS PDOP | 2 | Unsigned | 0 | 500 | 0.1 | - |
Probability |
Permanent I/O elements | |
182 | GNSS HDOP | 2 | Unsigned | 0 | 500 | 0.1 | - |
Probability |
Permanent I/O elements | |
24 | Speed | 2 | Unsigned | 0 | 350 | - | km/h |
Value |
Permanent I/O elements | |
205 | GSM Cell ID | 2 | Unsigned | 0 | 65535 | - | - |
GSM base station ID |
Permanent I/O elements | |
206 | GSM Area Code | 2 | Unsigned | 0 | 65535 | - | - |
Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. |
Permanent I/O elements | |
67 | Battery Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
241 | Active GSM Operator | 4 | Unsigned | 0 | 4294967295 | - | - |
Currently used GSM Operator code |
Permanent I/O elements | |
303 | Instant Movement | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 returns movement value | Permanent I/O elements | |
11 | ICCID1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Value of SIM ICCID, MSB | Permanent I/O elements | |
14 | ICCID2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - |
Value of SIM ICCID, MSB |
Permanent I/O elements | |
387 | ISO6709 Coordinates | 34 | HEX | 0 | 0x7fffffffffffffff | - | - | ISO6709 Coordinates
Latitude, Longitude (in Degrees, Minutes and Seconds) and Altitude: IO value format: ±DDMMSS.SSSS±DDDMMSS.SSSS±AAA.AAA/ |
Permanent I/O elements | |
636 | LTE Cell ID | 4 | Unsigned | 0 | 4294967295 | - | - | LTE Cell ID | Permanent I/O elements | |
288 | GSM Cell ID 1 | 2 | Unsigned | 0 | 65535 | - | - | Unique ID of the Cell 1 | Permanent I/O elements | |
291 | GSM Cell ID 2 | 2 | Unsigned | 0 | 65535 | - | - | Unique ID of the Cell 2 | Permanent I/O elements | |
294 | GSM Cell ID 3 | 2 | Unsigned | 0 | 65535 | - | - | Unique ID of the Cell 3 | Permanent I/O elements | |
297 | GSM Cell ID 4 | 2 | Unsigned | 0 | 65535 | - | - | Unique ID of the Cell 4 | Permanent I/O elements | |
287 | GSM Cell LAC 1 | 2 | Unsigned | 0 | 65534 | - | - | Location Area Code of the Cell 1 | Permanent I/O elements | |
290 | GSM Cell LAC 2 | 2 | Unsigned | 0 | 65534 | - | - | Location Area Code of the Cell 2 | Permanent I/O elements | |
293 | GSM Cell LAC 3 | 2 | Unsigned | 0 | 65534 | - | - | Location Area Code of the Cell 3 | Permanent I/O elements | |
296 | GSM Cell LAC 4 | 2 | Unsigned | 0 | 65534 | - | - | Location Area Code of the Cell 4 | Permanent I/O elements | |
1200 | GSM Cell MNC 1 | 1 | Unsigned | - | - | - | - | Mobile Network Code of the Cell 1 | Permanent I/O elements | |
1201 | GSM Cell MNC 2 | 1 | Unsigned | - | - | - | - | Mobile Network Code of the Cell 2 | Permanent I/O elements | |
1202 | GSM Cell MNC 3 | 1 | Unsigned | - | - | - | - | Mobile Network Code of the Cell 3 | Permanent I/O elements | |
1203 | GSM Cell MNC 4 | 1 | Unsigned | - | - | - | - | Mobile Network Code of the Cell 4 | Permanent I/O elements | |
286 | GSM Signal RX 0 | 1 | Unsigned | 0 | 63 | - | - | GSM Signal of the Cell 0 | Permanent I/O elements | |
289 | GSM Signal RX 1 | 1 | Unsigned | 0 | 63 | - | - | GSM Signal of the Cell 1 | Permanent I/O elements | |
292 | GSM Signal RX 2 | 1 | Unsigned | 0 | 63 | - | - | GSM Signal of the Cell 2 | Permanent I/O elements | |
295 | GSM Signal RX 3 | 1 | Unsigned | 0 | 63 | - | - | GSM Signal of the Cell 3 | Permanent I/O elements | |
298 | GSM Signal RX 4 | 1 | Unsigned | 0 | 63 | - | - | GSM Signal of the Cell 4 | Permanent I/O elements | |
25021 | LTE Cell ID 1 | 4 | Unsigned | 0 | 4294967295 | - | - | Unique ID of the LTE Cell 1 | Permanent I/O elements | |
25024 | LTE Cell ID 2 | 4 | Unsigned | 0 | 4294967295 | - | - | Unique ID of the LTE Cell 2 | Permanent I/O elements | |
25027 | LTE Cell ID 3 | 4 | Unsigned | 0 | 4294967295 | - | - | Unique ID of the LTE Cell 3 | Permanent I/O elements | |
25030 | LTE Cell ID 4 | 4 | Unsigned | 0 | 4294967295 | - | - | Unique ID of the LTE Cell 4 | Permanent I/O elements | |
25020 | LTE Cell LAC 1 | 2 | Unsigned | 0 | 65534 | - | - | Location Area Code of the LTE Cell 1 | Permanent I/O elements | |
25023 | LTE Cell LAC 2 | 2 | Unsigned | 0 | 65534 | - | - | Location Area Code of the LTE Cell 2 | Permanent I/O elements | |
25026 | LTE Cell LAC 3 | 2 | Unsigned | 0 | 65534 | - | - | Location Area Code of the LTE Cell 3 | Permanent I/O elements | |
25029 | LTE Cell LAC 4 | 2 | Unsigned | 0 | 65534 | - | - | Location Area Code of the LTE Cell 4 | Permanent I/O elements | |
25032 | LTE Cell MNC 1 | 1 | Unsigned | - | - | - | - | LTE Mobile Network Code of the Cell 1 | Permanent I/O elements | |
25033 | LTE Cell MNC 2 | 1 | Unsigned | - | - | - | - | LTE Mobile Network Code of the Cell 2 | Permanent I/O elements | |
25034 | LTE Cell MNC 3 | 1 | Unsigned | - | - | - | - | LTE Mobile Network Code of the Cell 3 | Permanent I/O elements | |
25035 | LTE Cell MNC 4 | 1 | Unsigned | - | - | - | - | LTE Mobile Network Code of the Cell 4 | Permanent I/O elements | |
25019 | LTE Signal RX 0 | 1 | Unsigned | 0 | 7 | - | - | LTE Signal of the Cell 0 | Permanent I/O elements | |
25022 | LTE Signal RX 1 | 1 | Unsigned | 0 | 7 | - | - | LTE Signal of the Cell 1 | Permanent I/O elements | |
25025 | LTE Signal RX 2 | 1 | Unsigned | 0 | 7 | - | - | LTE Signal of the Cell 2 | Permanent I/O elements | |
25028 | LTE Signal RX 3 | 1 | Unsigned | 0 | 7 | - | - | LTE Signal of the Cell 3 | Permanent I/O elements | |
25031 | LTE Signal RX 4 | 1 | Unsigned | 0 | 7 | - | - | LTE Signal of the Cell 4 | Permanent I/O elements | |
399 | Time To First Fix | 1 | Unsigned | 0 | 4294967295 | - | s | Amount of time it took to get first GNSS fix | Permanent I/O elements | |
20015 | Modem Uptime | 1 | Unsigned | 0 | 4294967295 | - | s | Modem Uptime since the last wake up | Permanent I/O elements | |
25015 | Modem Uptime | 8 | Unsigned | 0 | 4294967295 | - | s | Modem Uptime since the last wake up (from FW X.4.10.Rev.00) | Permanent I/O elements | |
20016 | LTE RSRP | 2 | Signed | -140 | -44 | - | dBm | Reference Signals Received Power | Permanent I/O elements | |
20017 | LTE RSRQ | 1 | Signed | -3 | -20 | - | dB | Reference Signals Received Quality | Permanent I/O elements | |
25016 | LTE RSRP | 2 | Signed | -140 | -44 | - | dBm | Reference Signals Received Power (from FW X.4.10.Rev.00) | Permanent I/O elements | |
25017 | LTE RSRQ | 1 | Signed | -20 | -3 | - | dB | Reference Signals Received Quality (from FW X.4.10.Rev.00) | Permanent I/O elements | |
Eventual I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
236 | Alarm | 1 | Unsigned | 0 | 1 | - | - | 0 – Reserved 1 – Alarm event occurred |
Eventual I/O elements | |
20012 | Recovery mode alarm | 1 | Unsigned | 0 | 2 | - | - | 0 – Reserved 1 – Reserved 2 – Recovery alarm event occurred |
Eventual I/O elements | |
20019 | Tamper record event | 2 | Unsigned | 0 | 3 | - | - | 0 – Holder is removed 1 – Central is attached 2 – Attached to metal surface 3 – Removed from metal surface |
Eventual I/O elements | |
20014 | BLE Lost Beacon | 1 | Unsigned | 0 | 3 | - | - | 0 – Reserved 1 – Reserved 2 – Reserved 3 – BLE Lost Beacon |
Eventual I/O elements | |
463 | BLE1 EYE sensor lost alarm | 2 | HEX | - | - | - | - | BEEF - BLE1 EYE sensor lost alarm | Eventual I/O elements | |
467 | BLE2 EYE sensor lost alarm | 2 | HEX | - | - | - | - | BEEF - BLE2 EYE sensor lost alarm | Eventual I/O elements | |
471 | BLE3 EYE sensor lost alarm | 2 | HEX | - | - | - | - | BEEF - BLE3 EYE sensor lost alarm | Eventual I/O elements | |
475 | BLE4 EYE sensor lost alarm | 2 | HEX | - | - | - | - | BEEF - BLE4 EYE sensor lost alarm | Eventual I/O elements |
BLE Sensor I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
25 | BLE Temperature #1 | 2 | Signed | -400 | 12050 | - | °C | Degrees ( °C ), -40 - +125; Error code: |
Bluetooth Low Energy | |
26 | BLE Temperature #2 | 2 | Signed | -400 | 12050 | - | °C | Degrees ( °C ), -40 - +125; Error code: |
Bluetooth Low Energy | |
27 | BLE Temperature #3 | 2 | Signed | -400 | 12050 | - | °C | Degrees ( °C ), -40 - +125; Error code: |
Bluetooth Low Energy | |
28 | BLE Temperature #4 | 2 | Signed | -400 | 12050 | - | °C | Degrees ( °C ), -40 - +125; Error code: |
Bluetooth Low Energy | |
29 | BLE Battery #1 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #1 | Bluetooth Low Energy | |
20 | BLE Battery #2 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #2 | Bluetooth Low Energy | |
22 | BLE Battery #3 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #3 | Bluetooth Low Energy | |
23 | BLE Battery #4 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #4 | Bluetooth Low Energy | |
86 | BLE Humidity #1 | 2 | Unsigned | 0 | 1000 | - | %RH | Humidity
Error code: |
Bluetooth Low Energy | |
104 | BLE Humidity #2 | 2 | Unsigned | 0 | 1000 | - | %RH | Humidity
Error code: |
Bluetooth Low Energy | |
106 | BLE Humidity #3 | 2 | Unsigned | 0 | 1000 | - | %RH | Humidity
Error code: |
Bluetooth Low Energy | |
108 | BLE Humidity #4 | 2 | Unsigned | 0 | 1000 | - | %RH | Humidity
Error code: |
Bluetooth Low Energy | |
331 | BLE 1 Custom #1 | 256 | HEX | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
332 | BLE 2 Custom #1 | 256 | HEX | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
333 | BLE 3 Custom #1 | 256 | HEX | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |
334 | BLE 4 Custom #1 | 256 | HEX | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth Low Energy | |