Template:AVL ID List - Permanent elements

From Wiki Knowledge Base | Teltonika GPS

To search for compatible products, Expand all content

Permanent I/O elements

Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
239 Ignition 1 Unsigned 0 1 - -

0 – Ignition Off
1 – Ignition On

Permanent I/O elements
240 Movement 1 Unsigned 0 1 - -

0 – Movement Off
1 – Movement On

Permanent I/O elements
80 Data Mode 1 Unsigned 0 5 - -

0 – Home On Stop
1 – Home On Moving
2 – Roaming On Stop
3 – Roaming On Moving
4 – Unknown On Stop
5 – Unknown On Moving

Permanent I/O elements
21 GSM Signal 1 Unsigned 0 5 - - Value in scale 1-5 Permanent I/O elements
200 Sleep Mode 1 Unsigned 0 4 - -

0 - Sleep modes disabled
1 – GNSS sleep
2 – Deep sleep
3 – Online deep sleep
4 - Ultra deep sleep

Permanent I/O elements
69 GNSS Status 1 Unsigned 0 3 - -

0 - GNSS OFF
1 – GNSS ON with fix
2 - GNSS ON without fix
3 - GNSS sleep

Permanent I/O elements
181 GNSS PDOP 2 Unsigned 0 500 0.1 -

Probability

Permanent I/O elements
182 GNSS HDOP 2 Unsigned 0 500 0.1 -

Probability

Permanent I/O elements
24 Speed 2 Unsigned 0 350 - km/h

Value

Permanent I/O elements
205 GSM Cell ID 2 Unsigned 0 65535 - -

GSM base station ID

Permanent I/O elements
206 GSM Area Code 2 Unsigned 0 65535 - -

Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations.

Permanent I/O elements
67 Battery Voltage 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
68 Battery Current 2 Unsigned 0 65535 0.001 A

Current

Permanent I/O elements
113 Battery Level 1 Unsigned 0 100 - % Battery capacity level Permanent I/O elements
66 External Voltage 2 Unsigned 0 65535 0.001 V IO element is used to measure External Voltage, when External Voltage is < 65V. Permanent I/O elements
800 Extended External Voltage 4 Unsigned 0 0xFFFF - V IO element is used to measure External Voltage, when External Voltage is > 65 V. Permanent I/O elements
241 Active GSM Operator 4 Unsigned 0 4294967295 - -

Currently used GSM Operator code

Permanent I/O elements
199 Trip Odometer 4 Unsigned 0 2147483647 - m

Trip Odometer value

Permanent I/O elements
16 Total Odometer 4 Unsigned 0 2147483647 - m Total Odometer value Permanent I/O elements
1 Digital Input 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
2 Digital Input 2 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
3 Digital Input 3 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
262 Digital Input 4 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
179 Digital Output 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
180 Digital Output 2 1 Unsigned 0 1 - - Logic 0/1 Permanent I/O elements
841 DOUT 1 Overcurrent 1 Unsigned 0 1 - - DOUT 1 Overcurrent IO element is used to indicate overcurrent on Digital Output 1. When Digital Output 1 overcurrent happens, it means that current level is > 300 mA, value is set to 1. Value 1 holds until 5 min timeout runs out. After timeout value is set to 0 if current level is < 300 mA. If current level is still > 300 mA value remains 1. Permanent I/O elements
842 DOUT2 Overcurrent 1 Unsigned 0 1 - - DOUT 2 Overcurrent IO element is used to indicate overcurrent on Digital Output 2. When Digital Output 2 overcurrent happens, it means that current level is > 300 mA, value is set to 1. Value 1 holds until 5 min timeout runs out. After timeout value is set to 0 if current level is < 300 mA. If current level is still > 300 mA value remains 1. Permanent I/O elements
9 Analog Input 1 2 Unsigned 0 65535 0.001 V Voltage Permanent I/O elements
6 Analog Input 2 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
839 Extended Analog Input 1 4 Unsigned 0 0xFFFF - V Extended Analog Input 1 IO element is used to measure Analog Input 1 voltage, when Analog Input 1 voltage is > 65 V. Permanent I/O elements
840 Extended Analog Input 2 4 Unsigned 0 0xFFFF - V Extended Analog Input 2 IO element is used to measure Analog Input 2 voltage, when Analog Input 1 voltage is > 65 V. Permanent I/O elements
303 Instant Movement 1 Unsigned 0 1 - - Logic: 0/1 returns movement value Permanent I/O elements
17 Axis X 2 Signed -8000 8000 0.001 G

X axis value

Permanent I/O elements
18 Axis Y 2 Signed -8000 8000 0.001 G

Y axis value

Permanent I/O elements
19 Axis Z 2 Signed -8000 8000 0.001 G

Z axis value

Permanent I/O elements
11 ICCID1 8 Unsigned 0 0xffffffffffffffff - - Value of SIM ICCID, MSB Permanent I/O elements
14 ICCID2 8 Unsigned 0 0xffffffffffffffff - -

Value of SIM ICCID, MSB

Permanent I/O elements
72 Dallas Temperature 1 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850
Permanent I/O elements
73 Dallas Temperature 2 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
74 Dallas Temperature 3 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
75 Dallas Temperature 4 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
76 Dallas Temperature ID 1 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
77 Dallas Temperature ID 2 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
79 Dallas Temperature ID 3 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
71 Dallas Temperature ID 4 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
78 iButton 8 Unsigned 0 0xffffffffffffffff - - iButton ID Permanent I/O elements
15 Eco Score 2 Unsigned 0 65535 0.01 - Average amount of events on some distance Permanent I/O elements
116 Charger Connected 1 Unsigned 0 1 - - 0 - charger is not connected

1 - charger is connected

Permanent I/O elements
854 User ID 4 Unsigned 0 0xFFFFFFFF - -

This parameter allows to send custom number as AVL ID parameter.
Configurable in Features section.

Permanent I/O elements
387 ISO6709 Coordinates 34 HEX 0 0x7fffffffffffffff - - ISO6709 Coordinates

Latitude, Longitude (in Degrees, Minutes and Seconds) and Altitude:

IO value format: ±DDMMSS.SSSS±DDDMMSS.SSSS±AAA.AAA/

Permanent I/O elements
636 LTE Cell ID 4 Unsigned 0 4294967295 - - LTE Cell ID Permanent I/O elements
288 GSM Cell ID 1 2 Unsigned 0 65535 - - Unique ID of the Cell 1 Permanent I/O elements
291 GSM Cell ID 2 2 Unsigned 0 65535 - - Unique ID of the Cell 2 Permanent I/O elements
294 GSM Cell ID 3 2 Unsigned 0 65535 - - Unique ID of the Cell 3 Permanent I/O elements
297 GSM Cell ID 4 2 Unsigned 0 65535 - - Unique ID of the Cell 4 Permanent I/O elements
287 GSM Cell LAC 1 2 Unsigned 0 65534 - - Location Area Code of the Cell 1 Permanent I/O elements
290 GSM Cell LAC 2 2 Unsigned 0 65534 - - Location Area Code of the Cell 2 Permanent I/O elements
293 GSM Cell LAC 3 2 Unsigned 0 65534 - - Location Area Code of the Cell 3 Permanent I/O elements
296 GSM Cell LAC 4 2 Unsigned 0 65534 - - Location Area Code of the Cell 4 Permanent I/O elements
1200 GSM Cell MNC 1 1 Unsigned - - - - Mobile Network Code of the Cell 1 Permanent I/O elements
1201 GSM Cell MNC 2 1 Unsigned - - - - Mobile Network Code of the Cell 2 Permanent I/O elements
1202 GSM Cell MNC 3 1 Unsigned - - - - Mobile Network Code of the Cell 3 Permanent I/O elements
1203 GSM Cell MNC 4 1 Unsigned - - - - Mobile Network Code of the Cell 4 Permanent I/O elements
286 GSM Signal RX 0 1 Unsigned 0 63 - - GSM Signal of the Cell 0 Permanent I/O elements
289 GSM Signal RX 1 1 Unsigned 0 63 - - GSM Signal of the Cell 1 Permanent I/O elements
292 GSM Signal RX 2 1 Unsigned 0 63 - - GSM Signal of the Cell 2 Permanent I/O elements
295 GSM Signal RX 3 1 Unsigned 0 63 - - GSM Signal of the Cell 3 Permanent I/O elements
298 GSM Signal RX 4 1 Unsigned 0 63 - - GSM Signal of the Cell 4 Permanent I/O elements
25021 LTE Cell ID 1 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 1 Permanent I/O elements
25024 LTE Cell ID 2 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 2 Permanent I/O elements
25027 LTE Cell ID 3 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 3 Permanent I/O elements
25030 LTE Cell ID 4 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 4 Permanent I/O elements
25020 LTE Cell LAC 1 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 1 Permanent I/O elements
25023 LTE Cell LAC 2 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 2 Permanent I/O elements
25026 LTE Cell LAC 3 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 3 Permanent I/O elements
25029 LTE Cell LAC 4 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 4 Permanent I/O elements
25032 LTE Cell MNC 1 1 Unsigned - - - - LTE Mobile Network Code of the Cell 1 Permanent I/O elements
25033 LTE Cell MNC 2 1 Unsigned - - - - LTE Mobile Network Code of the Cell 2 Permanent I/O elements
25034 LTE Cell MNC 3 1 Unsigned - - - - LTE Mobile Network Code of the Cell 3 Permanent I/O elements
25035 LTE Cell MNC 4 1 Unsigned - - - - LTE Mobile Network Code of the Cell 4 Permanent I/O elements
25019 LTE Signal RX 0 1 Unsigned 0 7 - - LTE Signal of the Cell 0 Permanent I/O elements
25022 LTE Signal RX 1 1 Unsigned 0 7 - - LTE Signal of the Cell 1 Permanent I/O elements
25025 LTE Signal RX 2 1 Unsigned 0 7 - - LTE Signal of the Cell 2 Permanent I/O elements
25028 LTE Signal RX 3 1 Unsigned 0 7 - - LTE Signal of the Cell 3 Permanent I/O elements
25031 LTE Signal RX 4 1 Unsigned 0 7 - - LTE Signal of the Cell 4 Permanent I/O elements
399 Time To First Fix 1 Unsigned 0 4294967295 - s Amount of time it took to get first GNSS fix Permanent I/O elements
20015 Modem Uptime 1 Unsigned 0 4294967295 - s Modem Uptime since the last wake up Permanent I/O elements
25015 Modem Uptime 8 Unsigned 0 4294967295 - s Modem Uptime since the last wake up (from FW X.4.10.Rev.00) Permanent I/O elements
20016 LTE RSRP 2 Signed -140 -44 - dBm Reference Signals Received Power Permanent I/O elements
20017 LTE RSRQ 1 Signed -3 -20 - dB Reference Signals Received Quality Permanent I/O elements
25016 LTE RSRP 2 Signed -140 -44 - dBm Reference Signals Received Power (from FW X.4.10.Rev.00) Permanent I/O elements
25017 LTE RSRQ 1 Signed -20 -3 - dB Reference Signals Received Quality (from FW X.4.10.Rev.00) Permanent I/O elements
449 Ignition On Counter value Unsigned 0 2147483647 - s Current value of the counter Permanent I/O elements
10800 EYE Temperature 1 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 1 Permanent I/O elements
10801 EYE Temperature 2 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 2 Permanent I/O elements
10802 EYE Temperature 3 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 3 Permanent I/O elements
10803 EYE Temperature 4 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 4 Permanent I/O elements
10804 EYE Humidity 1 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 1 Permanent I/O elements
10805 EYE Humidity 2 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 2 Permanent I/O elements
10806 EYE Humidity 3 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 3 Permanent I/O elements
10807 EYE Humidity 4 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 4 Permanent I/O elements
10808 EYE Magnet 1 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 1 Permanent I/O elements
10809 EYE Magnet 2 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 2 Permanent I/O elements
10810 EYE Magnet 3 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 3 Permanent I/O elements
10811 EYE Magnet 4 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 4 Permanent I/O elements
10812 EYE Movement 1 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 1 Permanent I/O elements
10813 EYE Movement 2 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 2 Permanent I/O elements
10814 EYE Movement 3 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 3 Permanent I/O elements
10815 EYE Movement 4 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 4 Permanent I/O elements
10816 EYE Pitch 1 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 1 Permanent I/O elements
10817 EYE Pitch 2 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 2 Permanent I/O elements
10818 EYE Pitch 3 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 3 Permanent I/O elements
10819 EYE Pitch 4 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 4 Permanent I/O elements
10820 EYE Low Battery 1 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 1 Permanent I/O elements
10821 EYE Low Battery 2 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 2 Permanent I/O elements
10822 EYE Low Battery 3 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 3 Permanent I/O elements
10823 EYE Low Battery 4 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 4 Permanent I/O elements
10824 EYE Battery Voltage 1 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 1 Permanent I/O elements
10825 EYE Battery Voltage 2 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 2 Permanent I/O elements
10826 EYE Battery Voltage 3 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 3 Permanent I/O elements
10827 EYE Battery Voltage 4 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 4 Permanent I/O elements
10832 EYE Roll 1 2 Signed -180 180 - - Roll angle measured by EYE Sensor 1 Permanent I/O elements
10833 EYE Roll 2 2 Signed -180 180 - - Roll angle measured by EYE Sensor 2 Permanent I/O elements
10834 EYE Roll 3 2 Signed -180 180 - - Roll angle measured by EYE Sensor 3 Permanent I/O elements
10835 EYE Roll 4 2 Signed -180 180 - - Roll angle measured by EYE Sensor 4 Permanent I/O elements
10836 EYE Movement count 1 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 1 Permanent I/O elements
10837 EYE Movement count 2 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 2 Permanent I/O elements
10838 EYE Movement count 3 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 3 Permanent I/O elements
10839 EYE Movement count 4 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 4 Permanent I/O elements
10840 EYE Magnet count 1 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 1 Permanent I/O elements
10841 EYE Magnet count 2 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 2 Permanent I/O elements
10842 EYE Magnet count 3 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 3 Permanent I/O elements
10843 EYE Magnet count 4 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 4 Permanent I/O elements
11317 EYE Sensor List variable length HEX 0 bytes 1024 bytes - - EYE Sensor List Permanent I/O elements