Template:FMB Device Family Accelerometer Features Parameter list

From Teltonika Telematics Wiki

Accelerometer features

Unplug Detection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11500 Uint8 0 0 3 0 – Disable Scenario setting
1 – Low priority
2 – High priority
3 – Panic priority
11501 Uint8 1 0 1 0 - Disable Eventual records
1 - Enable
11502 Uint8 1 0 1 0 - Simple Detection mode
1 - Advanced
7036 Uint8 0 0 10 Phone number Send SMS to
8036 String "Unplug" 0 160 Text Sms text

Towing Detection


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11600 Uint8 0 0 3 0 – Disable Priority
1 – Low priority
2 – High priority
3 – Panic priority
11601 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11602 Uint16 5 0 65535 Minutes Activation timeout
11603 Uint8 0 0 60 Seconds Event timeout
11604 Uint8 0 0 10 Phone number Make call to
11605 Double 0.22 0.1 5 mG Threshold
11606 Double 1 0.1 5 Degrees Angle
11607 Uint16 1000 1 5000 Milliseconds Duration
7035 Uint8 0 0 10 Phone number Send SMS to
8035 String "Towing" 0 160 Text Sms text

Crash Detection


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11400 Uint8 0 0 3 0 – Disable Scenario setting
1 – Low priority
2 – High priority
3 – Panic priority
11401 Uint8 5 0 1000 Milliseconds Duration
11402 Uint16 1500 0 7900 mG Threshold
11406 Int8 0 0 1 0 - Disable Crash trace
1 - Enable
7037 Uint8 0 0 10 Phone number Send SMS to
8037 String "Crash" 0 160 Text Sms text

Excessive Idling


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11200 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11203 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11205 Uint8 5 0 3600 Seconds Time to stoped
11206 Uint8 2 0 3600 Seconds Time to moving
11204 Uint8 0 0 2 (1 for FMB125) 0 – None Output control
1 – DOUT 1
2 – DOUT 2
11201 Int32 200 0 2147483647 Milliseconds DOUT ON duration
11202 Int32 200 0 2147483647 Milliseconds DOUT OFF duration
7033 Uint8 0 0 10 Phone number Send SMS to
8033 String "Idling Event" 0 160 Text Sms text

Motorcycle Fall Detection


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13700 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
13701 Uint8 45 30 150 Degree Angle value
13702 Uint8 5 0 60 Seconds Alarm Delay
13703 Uint16 15 0 65500 Seconds Active Time
13704 Uint8 0 0 3 0 - Disabled Active Time
1 – DOUT 1
2 – DOUT 2
13705 Uint32 200 100 2147483647 Milliseconds DOUT ON Duration
13706 Uint32 200 0 2147483647 Milliseconds DOUT OFF Duration
7585 Byte 0 0 10 Phone number Send SMS to
8585 String MotorcycleFallDetection 0 160 Text SMS Text