From Wiki Knowledge Base | Teltonika GPS
Trip scenario parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11800
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11801
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Eventual records
|
1 – Enable
|
11802
|
Uint8
|
0
|
0
|
1
|
0 – Continuous
|
Mode
|
1 – Between records
|
11803
|
Uint8
|
5
|
0
|
255
|
km/h
|
Start speed
|
11804
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Ignition off timeout
|
7031
|
Uint8
|
0
|
0
|
10
|
Phone number
|
Send SMS to
|
8031
|
String
|
"Trip"
|
0
|
160
|
Text
|
Sms text
|
Advanced trip scenario parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
700
|
Uint16
|
100
|
0
|
65535
|
0 – Disable
|
Eco score allowed events
|
11805
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Remember iButton
|
1 – Enable
|
Odometer parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11806
|
Uint8
|
0
|
0
|
2
|
0 – GNSS
|
Calculation source
|
1 – OBD
|
2 – LVCAN
|
11807
|
Uint32
|
0
|
0
|
4294967
|
Kilometer
|
Odometer Value
|