Characteristic description | Value | |||
---|---|---|---|---|
Min. | Typ. | Max. | Unit | |
Supply Voltage: | ||||
Supply Voltage (Recommended Operating Conditions) |
+10 | +30 | V | |
Digital Output (Open Drain grade): | ||||
Drain current (Digital Output OFF) | 120 | µA | ||
Drain current (Digital Output ON, Recommended Operating Conditions) |
0.1 | 0.5 | A | |
Static Drain-Source resistance (Digital Output ON) |
400 | 600 | mΩ | |
Digital Input: | ||||
Input resistance (DIN1) | 47 | kΩ | ||
Input resistance (DIN2) | 51.7 | kΩ | ||
Input resistance (DIN3) | 47 | kΩ | ||
Input voltage (Recommended Operating Conditions) |
0 | Supply voltage | V | |
Input Voltage threshold (DIN1) | 7.5 | V | ||
Input Voltage threshold (DIN2) | 2.5 | V | ||
Input Voltage threshold (DIN3) | 2.5 | V | ||
Analog Input: | ||||
Input voltage (Recommended Operating Conditions), Range 1 |
0 | +10 | V | |
Input resistance, Range 1 | 150 | kΩ | ||
Measurement error on 12V, Range 1 | 3 | % | ||
Additional error on 12 V, Range 1 | 360 | mV | ||
Measurement error on 30 V, Range 1 | 3 | % | ||
Additional error on 30 V, Range 1 | 900 | mV | ||
Input Voltage (Recommended Operating Conditions), Range 2 |
0 | +30 | V | |
Input resistance, Range 2 | 150 | kΩ | ||
Measurement error on 12V, Range 2 | 3 | % | ||
Additional error on 12 V, Range 2 | 360 | mV | ||
Measurement error on 30 V, Range 2 | 3 | % | ||
Additional error on 30 V, Range 2 | 900 | mV | ||
Output Supply Voltage 1-Wire: | ||||
Supply voltage | +4.5 | +4.7 | V | |
Output inner resistance | 7 | Ω | ||
Output current (Uout > 3.0 V) | 30 | mA | ||
Short circuit current (Uout = 0) | 75 | mA |
Ground sense: | ||||
Input resistance | 38.45 | kΩ | ||
Input voltage (Recommended operating conditions) |
0 | Supply voltage | V | |
Input voltage threshold | 0.5 | V | ||
Sink current | 180 | nA |
CAN interface: | ||||
Internal terminal resistor CAN bus (no internal termination resistor) |
- | - | - | Ω |
Differential input resistance | 19 | 30 | 52 | kΩ |
Recessive output voltage | 2 | 2.5 | 3 | V |
Differential receiver threshold Voltage | 0.5 | 0.7 | 0.9 | V |
Common mode input voltage | -30 | - | 30 | V |
Analog Input error margin can increase if temperature varies. |
Absolute maximum ratings
Characteristic description | Value | |||
---|---|---|---|---|
Min. | Typ. | Max. | Unit | |
Supply Voltage (Absolute Maximum Ratings) |
-32 | +32 | V | |
Drain-Source clamp threshold voltage (Absolute Maximum Ratings), (Idrain = 2 mA) |
+36 | V | ||
Digital Input Voltage (Absolute Maximum Ratings) |
-32 | +32 | V | |
Analog Input Voltage (Absolute Maximum Ratings) |
-32 | +32 | V |