Template:FTX Data Sending Parameters ID

From Teltonika Telematics Wiki

{{{model}}} AVL IDs consist of these parameter groups:

Permanent I/O elements


Property ID in AVL packet Property Name Bytes Type Min Value Max Value Multiplier Units Description Parameter Group
16 Total Odometer 4 Unsigned 0 2147483647 - m Virtual odometer value Permanent I/O elements
17 Axis X 2 Signed -8000 8000 - mg Axis X value Permanent I/O elements
18 Axis Y 2 Signed -8000 8000 - mg Axis Y value Permanent I/O elements
19 Axis Z 2 Signed -8000 8000 - mg Axis Z value Permanent I/O elements
21 GSM Signal 1 Unsigned 0 5 - - Value in range 1-5 Permanent I/O Elements
67 Battery Voltage 2 Unsigned 0 65535 - mV Voltage Permanent I/O elements
68 Battery Current 2 Unsigned 0 65535 - mA Current Permanent I/O elements
70 PCB temperature 2 Signed -550 1150 - °C Degrees Permanent I/O elements
113 Battery level 1 Unsigned 0 100 - °C Battery capacity level Permanent I/O elements
181 GNSS PDOP 2 Unsigned 0 500 - - GNSS position dilution of precision.
Normal PDOP is below 3 – the lower the number, the more accurate reported location is.
Permanent I/O elements
182 GNSS HDOP 2 Unsigned 0 500 - - GNSS horizontal dilution of precision.
Normal HDOP is below 2 – the lower the number, the more accurate reported location is.
Permanent I/O elements
199 Trip Odometer 4 Unsigned 0 2147483647 - m Trip distance value calculated by GNSS Permanent I/O elements
205 GSM Cell ID 4 Unsigned 0 2147483647 - - GSM base station ID Permanent I/O elements
206 GSM Area Code 2 Unsigned 0 65535 - - Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. Permanent I/O elements
237 Network Type 1 Unsigned 0 1 - - 0 - 3G
1 - GSM
2 - 4G
3 - LTE CAT M1
4 - LTE CAT NB1
99 - Unknown
Permanent I/O elements
239 Ignition 1 Unsigned 0 1 - - 0 – Ignition Off
1 – Ignition On
Permanent I/O Elements
240 Movement 1 Unsigned 0 1 - - 0 – Movement Off
1 – Movement On
Permanent I/O Elements
241 GSM operator code 4 Unsigned 0 4294967295 - - Currently used GSM Operator code Permanent I/O elements
303 Instant Movement 1 Unsigned 0 1 - - Logic: 0/1 returns movement value Permanent I/O elements
383 Accel calibration status 1 Unsigned 0 1 - - 0 - not calibrated (empty)
1 - calibrated, but not fully (present)
2 - disabled
3 - fully calibrated (full)
Permanent I/O elements
449 Ignition on counter 4 Unsigned 0 2147483647 - s Ignition on counter value Permanent I/O elements
641 ICCID 22 ASCII 0 22 - - Value of SIM ICCID (Integrated circuit card identification number) Permanent I/O elements
800 External Voltage 2 Unsigned 0 4294967295 - mV Voltage Permanent I/O elements
1148 Connectivity quality 4 Unsigned 0 2147483647 - dBm Provides detailed signal quality information in LTE, eMTC (CAT-Mx) and NB-IoT modes:
RSSI (byte 0): 0 - 255 in dBm (negative values)
RSRP (byte 1): 0 - 255 in dBm (negative values)
SINR (byte 2): 0 - 250 which translates to -20dB to +30dB (1/5th of dB)
RSRQ (byte 3): 0 - 255 in dB (negative values)
Permanent I/O elements
1452 Faulty Device Mounting 1 Unsigned 0 1 - - 1 - high vibrations detected
0 - device is mounted properly
Permanent I/O elements
13361 Incoming call detection 1 Unsigned 0 1 - - 0 – no incoming call
1 – an incoming call is in progress
Permanent I/O elements

Eventual I/O elements


Property ID in AVL packet Property Name Bytes Type Min Value Max Value Multiplier Units Description Parameter Group
247 Crash detection 1 Unsigned 1 6 - - 1 – crash
2 – limited crash trace (device not calibrated)
3 - limited crash trace (device is calibrated)
4 - full crash trace (device not calibrated)
5 - full crash trace (device is calibrated)
6 - crash detected (device not calibrated)
Eventual I/O elements
1429 Crash average vector 8 Unsigned - - - mG Stores the average vector calculated during the crash: 2B - X axis, 2B - Y axis, 2B - Z axis, 2B - magnitude in mG. Eventual I/O elements
1430 Crash direction - Unsigned - - - - Stores the indication if the accelerometer is calibrated.
Also, indicates the direction of the crash.
1 bit (highest bit) indicates calibration status, rest of the bits indicates crash direction.
Eventual I/O elements
1431 Crash duration - Unsigned - - - - Duration of the crash event Eventual I/O elements
1432 Crash max vector 8 Unsigned - - - mG Stores the max vector calculated during the crash: 2B - X axis, 2B - Y axis, 2B - Z axis, 2B - magnitude in mG. Eventual I/O elements
255 Over Speeding 1 Unsigned 0 255 - km/h At over speeding start km/h, at over speeding end km/h Eventual I/O elements
250 Trip 1 Unsigned 0 1 - - 0 – trip stop
1 – trip start
2 – Business Status
3 – Private Status
4-9 – Custom Statuses
Eventual I/O elements
253 Eco driving type 1 Unsigned 1 3 - - 1 – harsh acceleration
2 – harsh braking
3 – harsh cornering
Eventual I/O elements
254 Eco driving value 1 Unsigned 0 255 acc and braking: 0.01 G
or
rad
Depending on Eco driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g). If Eco driving source is „GPS“ – harsh cornering value is rad/s*100. If source is „Accelerometer“ – g*100. Eventual I/O elements
251 Excessive idling 1 Unsigned 0 1 - - 0 – moving
1 – idling
Eventual I/O elements
249 Network jamming detection 1 Unsigned 0 1 - - Logic: 0/1 Eventual I/O elements
252 Unplug detection 1 Unsigned 0 1 - - 0 – battery present
1 – battery unplugged
Eventual I/O elements
175 Auto geofence 1 Unsigned 0 1 - - 0 – target left zone
1 – target enetered zone
Eventual I/O elements
246 Towing detection 1 Unsigned 0 1 - - 0 – steady
1 – towing
Eventual I/O elements
242 Fall down detection 1 Unsigned 0 1 - - 0 – Fall down deactivated
1 – Fall down is active
Eventual I/O elements
358 Custom scenario 1 1 Unsigned 0 1 - - - Eventual I/O elements
359 Custom scenario 2 1 Unsigned 0 1 - - - Eventual I/O elements
360 Custom scenario 3 1 Unsigned 0 1 - - - Eventual I/O elements


[[Category:{{{model}}}]]