Template:SAS device Parameter list - AutoGeofence
Appearance
Auto Geofence
Auto Geofence
| Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
|---|---|---|---|---|---|---|
| Min | Max | |||||
| 20000 | Uint8 | 0 | 0 | 3 | 0 – Disable | Priority |
| 1 – Low Priority | ||||||
| 2 – High Priority | ||||||
| 3 – Panic Priority | ||||||
| 20002 | Uint8 | 1 | 0 | 1 | 0 – Disable | Eventual records |
| 1 – Enable | ||||||
| 20001 | Uint8 | 0 | 0 | 2 | 0 - On exiting zone | Generate Event |
| 1 - On entering zone | ||||||
| 2 - On both | ||||||
| 20003 | Uint8 | 60 | 0 | 65535 | Seconds | Activation Timeout |
| 20004 | Uint16 | 100 | 5 | 1000000 | Meters | Radius |
| 20005 | Uint8 | 0 | 0 | 2 | 0 - Power Voltage | Generate Event |
| 1 - Digital Input1 | ||||||
| 2 - Engine RPM | ||||||
| 7030 | Uint64 | "" | 0 | 10 | Predefined Number | Send SMS to |
| 8030 | String | AutoGeofence | 0 | 160 | Text | SMS text |
| 20006 | Uint8 | 0 | 0 | 1 | 0 – Disable | Call Settings |
| 1 – Enable | ||||||
| 20007 | Uint16 | "" | 0 | 10 | Predefined Number | Call to |