From Teltonika Telematics Wiki
RS232
Mode
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
150
|
Uint16
|
0
|
0
|
1
|
0 – Disable
|
External UART Mode
|
1 – RS232
|
RS232 Mode
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
151
|
Uint16
|
0
|
0
|
10
|
0 – Log Mode
|
Eventual Records
|
1 – NMEA
|
7 – TCP Ascii
|
8 – TCP Binary
|
9 – TCP Ascii Buffered
|
10 – TCP Binary Buffered
|
RS232 Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
153
|
Uint16
|
1
|
0
|
1
|
0 – Default
|
Eventual Records (Parity)
|
1 – None
|
2 – Odd
|
3 – Even
|
152
|
Uint16
|
1
|
0
|
1
|
0 – Default
|
Baudrate
|
1 – 1200
|
2 – 2400
|
3 – 9600
|
4 – 14400
|
5 – 19200
|
6 – 38400
|
7 – 57600
|
8 – 115200
|
158
|
Uint16
|
0
|
0
|
1
|
0 – Disable
|
Message Timestamp
|
1 – Enable
|
TCP Binary Mode Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
154
|
Uint8
|
0
|
0
|
255
|
-
|
Prefix 1
|
155
|
Uint8
|
0
|
0
|
255
|
-
|
Prefix 2
|
156
|
Uint8
|
0
|
0
|
255
|
-
|
Prefix 3
|