Possible responses: | Possible responses: | ||
− | * From '''[[ | + | * From '''[[ALL-CAN300]]''': |
** ''CAN'''X''':0x'''YY'''[,],'' where: | ** ''CAN'''X''':0x'''YY'''[,],'' where: | ||
*** '''X''' – CAN number | *** '''X''' – CAN number | ||
*** '''YY''' – the status of CAN line: | *** '''YY''' – the status of CAN line: | ||
− | **** '''00''' – CAN not connected, not required | + | **** '''00''' – CAN not connected, connection not required |
**** '''01''' – CAN connected, but currently module not received data | **** '''01''' – CAN connected, but currently module not received data | ||
**** '''02''' – CAN not connected, require connection | **** '''02''' – CAN not connected, require connection | ||
Line 13: | Line 13: | ||
*** LVCAN not detected | *** LVCAN not detected | ||
− | * From '''[[ | + | * From '''[[CAN-CONTROL]]''', '''[[FMB140]]''': |
** ''CAN'''X''':0x'''YY'''[,],'' where: | ** ''CAN'''X''':0x'''YY'''[,],'' where: | ||
*** '''X''' – CAN number | *** '''X''' – CAN number | ||
Line 20: | Line 20: | ||
**** '''01''' – CAN connected, the currently module received data | **** '''01''' – CAN connected, the currently module received data | ||
**** '''02''' – CAN not connected, require connection | **** '''02''' – CAN not connected, require connection | ||
− | **** '''03''' – CAN not connected, not required | + | **** '''03''' – CAN not connected, connection not required |
** Examples of responses: | ** Examples of responses: | ||
*** CAN1:0x03,CAN2:0x02,CAN3:0x03 | *** CAN1:0x03,CAN2:0x02,CAN3:0x03 | ||
*** CAN line flags are empty! | *** CAN line flags are empty! | ||
*** LVCAN not detected | *** LVCAN not detected |
Revision as of 12:56, 24 October 2022
Possible responses:
- From ALL-CAN300:
- CANX:0xYY[,], where:
- X – CAN number
- YY – the status of CAN line:
- 00 – CAN not connected, connection not required
- 01 – CAN connected, but currently module not received data
- 02 – CAN not connected, require connection
- 03 – CAN connected
- Examples of responses:
- CAN1:0x03,CAN2:0x02,CAN3:0x03
- CAN line flags are empty!
- LVCAN not detected
- CANX:0xYY[,], where:
- From CAN-CONTROL, FMB140:
- CANX:0xYY[,], where:
- X – CAN number
- YY – the status of CAN line:
- 00 – CAN connected, but currently module not received data
- 01 – CAN connected, the currently module received data
- 02 – CAN not connected, require connection
- 03 – CAN not connected, connection not required
- Examples of responses:
- CAN1:0x03,CAN2:0x02,CAN3:0x03
- CAN line flags are empty!
- LVCAN not detected
- CANX:0xYY[,], where: