Product change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc.
This page stores information regarding changes to the FMC650 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).
2025.07.30: New PCB changes
We would like to inform you about the new PCB changes with two separate nano SIM slots starting in start - September 2025.
Change description
Change type
Intenal/visual
Detailed description
SIM Holder changes on PCB – instead of DualSIM Holder that fits 2 full-size (2FF) SIM cards – new PCB will have 2 SIM holders that fit Nano SIM (4FF) size cards.
Old version
New version
Device SIM placement by the photo is that SIM1 will be placed at the left side and SIM2 at the right side
Change reasons
Currently most of the SIM cards provided by operators can be disassembled into 3 parts - Standard/Micro/Nano. Depending on the SIM card construction - during device usage in harsh conditions, SIM assembly might come apart which causes instability when connecting to the operator.
The new nano SIM slot design eliminates these tolerance issues, resulting in improved SIM card detection and reliability.
Product release date
Planned date: September, 2025 will be started manufacture. October and November will be transitioning period
Affected products
Model
Affected order codes
Order code changes
FMC650
FMC650*******order codes
No changes
Change impact
Risk assessment
Teltonika Telematics Hardware and QA teams have tested the updated SIM slot, which now supports nano SIM cards directly. This change algines with current market trends favoring nano SIM formats. The new nano SIM slot design eliminates these tolerance issues, resulting in improved SIM card detection and reliability.
Most of the SIM cards provided by operators can be disassembled into 3 parts - Standard/Micro/Nano. Therefore, during transitioning period and/or if you have a stock of SIM cards – the SIM cards can still be used up.
Suggested implementation plan
Recheck with your operator if the SIM cards you are orderring can be dissasembled into 3 parts (Mini SIM/Micro Sim/Nano SIM)
Update the end user/installer documentations providing updated information on SIM1/SIM2 locations. From the left side of photo is SIM1 from the right side is SIM2
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2025.07.30: New SPQ 5 packing
We would like to inform you about the new possible upcomming package with 5 devices option starting in start - August 2025.
Change description
Change type
New variant of packing for 5 devices in one box (SPQ:5)
Detailed description
For more eco friendly environment new packecking is available with 5 devices in one box and all default components. In first layer of box are antennas and power cablse, on second layer devices. (SPQ:5)
First box layer:
Second box layer:
Change reasons
New possible way to order device with 5 pieces in one box of FMC650)
Product release date
Planned date: 2025, August
Affected products
Model
Affected order codes
Order code changes
FMC650-MBX50, FMC650-MCX50
FMC6501T5S01, FMC6508T5S01 order codes
No changes
Change impact
Risk assessment
New packecking was checked by Teltonika Telematics Hardware team and EMS manufacuture engineers. Drop tests were performed and passed.
Suggested implementation plan
If you want to update your SPQ1 code to SPQ5, you can contact your sales manager for order code update.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2025.07.30: New RJ45 (COM1/2) components changes
We would like to inform you about the new RJ45 visual components changes starting in start - September 2025.
Change description
Change type
Intenal/visual
Detailed description
RJ45(COM1/2) visual component change. New component has same specifications as the previous RJ45. The main change is in color. Old one had black color new one will have grey color
Old version:
New Version:
Change reasons
Reaction to RJ45 market volatility.
Product release date
Planned date: September, 2025 will be started manufacture. October and November will be transitioning period
Affected products
Model
Affected order codes
Order code changes
FMC650
FMC650*******order codes
No changes
Change impact
Risk assessment
New RJ45 component was tested by Teltonika Telematics QA team.
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2025.05.27: Base firmware update
We would like to inform you about the base firmware update for FMC650 starting in start - June 2025. New production firmware version will be 03.01.00.Rev.14.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically.
During transitional period, codes ordered with base Firmware version might contain 03.00.17.Rev.06 Firmware versions.
Suggested implementation plan
If you are using a special firmware version and would like an upgrade to new features of the latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2024.09.28: Base firmware update
We would like to inform you about the base firmware update for FMC650 starting in start - March 2024. New production firmware version will be 03.00.17.Rev.rev.06.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically.
During transitional period, codes ordered with base Firmware version might contain 03.00.15.Rev.13 Firmware versions.
Suggested implementation plan
If you are using a special firmware version and would like an upgrade to new features of the latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2024.03.22: Base firmware update
We would like to inform you about the base firmware update for FMC650 starting in start - March 2024. New production firmware version will be 03.00.15.Rev.13.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically.
During transitional period, codes ordered with base Firmware version might contain 03.00.15.Rev.09 Firmware versions.
Suggested implementation plan
If you are using a special firmware version and would like an upgrade to new features of the latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2023.12.14: Base firmware update
We would like to inform you about the base firmware update for FMC650 starting in start - December 2023. New production firmware version will be 03.00.15.Rev.09.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically.
Security keyword removing or changing functionality configuration doesn't work properly, we suggest do not change or delete any not set or current set keywords on the device. Fix for this issue coming with next firmware versions
During transitional period, codes ordered with base Firmware version might contain 03.00.14.Rev.11 Firmware versions.
Suggested implementation plan
If you are using a special firmware version and would like an upgrade to new features of the latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2023.08.22: Base firmware update
We would like to inform you about the base firmware update for FMC650 starting in start - Semptember 2023. New production firmware version will be 03.00.14.Rev.11.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically.
During transitional period, codes ordered with base Firmware version might contain 03.00.14.Rev.01 Firmware versions.
Suggested implementation plan
If you are using a special firmware version and would like an upgrade to new features of the latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2023.05.30: Base firmware update
We would like to inform you about the base firmware update for FMC650 starting in start - June 2023. New production firmware version will be 03.00.14.Rev.01.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically.
During transitional period, codes ordered with base Firmware version might contain 03.00.13.Rev.05 Firmware versions.
Suggested implementation plan
If you are using a special firmware version and would like an upgrade to new features of the latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2023.04.12: SIM usage recommendation update
We would like to inform you about the SIM usage recommendation change - due to SIM card market tendencies (Standard size SIM cards being made to split to 3 parts) FMC640 First Start
Recommendation description
Recommendation reason
Due to SIM card market tendencies (Standard size SIM cards being made to split to 3 parts)
Detailed description
New paragraph about SIM usage is added to product First Start description.
Previously SIM insertion recommendation was only described in schematics - SIM1 shown in lower slot, SIM2 in upper slot.
Due to SIM market tendencies the documentation was updated to more clearly state SIM1 and SIM2 usage recommendations:
FMX6 devices use Standard size SIM cards for SIM1 and SIM2. Currently most of the SIM cards provided by operators can be disassembled into 3 parts - Standard/Micro/Nano. Depending on the SIM card construction - during device usage in harsh conditions, SIM assembly might come apart which causes instability when connecting to operator.
To avoid such risk:
1) If possible - ask operator for Standard SIM card with solid construction (not pre-cut to 3 parts)
2) Do not use SIM cards that were previously disassembled (SIM was taken apart previously)
3) If you plan to use only one SIM card - insert it into SIM1 slot (lower slot) - this ensures greater pressure on SIM contacts as the contact bed is pushed by PCB.
When 2 SIM cards are used simultaneously risk is mitigated as well - when SIM1 is inserted, a greater pressure is applied for SIM2, so SIM parts are harder to come lose
Change impact
Risk assessment
Recommendation updated to mitigate risk.
Suggested implementation plan
If you used one SIM card and it's placed in SIM1 slot (lower) - no implementation plan needed.
If you used 2 SIM cards - SIM1 in lower slot, SIM2 in upper slot - no implementation plan needed.
If you used eSIM - no implementation plan needed.
If you used one SIM card and it is inserted into SIM2 slot (upper) - to mitigate risk of bad operator connectivity due to SIM construction - for future installations - when only 1 SIM card is used - insert it into SIM1 slot (lower)