Changes

m
Text formatting
Line 3: Line 3:  
{{{image1|[[Image:FMB630_autoCAN1.png|center|200px]]}}}
 
{{{image1|[[Image:FMB630_autoCAN1.png|center|200px]]}}}
   −
* SCAN scans once for available messages on CAN bus;
+
* SCAN - scans once for available messages on CAN bus;
 
* Monitoring – toggles scanning of messages on CAN bus every 3 seconds;
 
* Monitoring – toggles scanning of messages on CAN bus every 3 seconds;
 
* Offline Configuration – enables CAN configuration when {{{model|FMB630}}} is not connected to CAN bus;
 
* Offline Configuration – enables CAN configuration when {{{model|FMB630}}} is not connected to CAN bus;
Line 16: Line 16:  
* Value – shows scanned value of parameter;
 
* Value – shows scanned value of parameter;
 
* Send data to server – allows to choose the type of data when it‘s generated:
 
* Send data to server – allows to choose the type of data when it‘s generated:
o Disabled – Data will not be collected
+
* Disabled – Data will not be collected
o On low priority – records will be generated as low priority events;  
+
* On low priority – records will be generated as low priority events;  
o On high priority – records will be generated as high priority events and immediately sent to server via GPRS (if GPRS is available);
+
* On high priority – records will be generated as high priority events and immediately sent to server via GPRS (if GPRS is available);
o On panic - records will be generated as panic priority events and immediately sent to server via GPRS, if GPRS is not available records will be sent via SMS messages;
+
* On panic - records will be generated as panic priority events and immediately sent to server via GPRS, if GPRS is not available records will be sent via SMS messages;
 
* Data acquisition type – allows to choose when records are generated:
 
* Data acquisition type – allows to choose when records are generated:
oMonitoring – monitors data;
+
*Monitoring – monitors data;
oOn change – record is generated when parameter value is changed;
+
*On change – record is generated when parameter value is changed;
oHysteresis – record is generated when increasing parameter value becomes higher than High value, and decreasing becomes less than Low value
+
*Hysteresis – record is generated when increasing parameter value becomes higher than High value, and decreasing becomes less than Low value
oEvent on exit – record is generated when parameter value becomes higher than High value or lower than Low value;
+
*Event on exit – record is generated when parameter value becomes higher than High value or lower than Low value;
oEvent on entrance – record is generated when parameter value becomes between High and Low values;
+
*Event on entrance – record is generated when parameter value becomes between High and Low values;
oEvent on both – record is generated when parameter value crosses High or Low values;
+
*Event on both – record is generated when parameter value crosses High or Low values;
 
* Low – allows to choose low value for Data acquisition;
 
* Low – allows to choose low value for Data acquisition;
 
* High – allows to choose High level for Data acquisition;
 
* High – allows to choose High level for Data acquisition;

Navigation menu