Line 3: |
Line 3: |
| {{{image1|[[Image:FMB630_autoCAN1.png|center|200px]]}}} | | {{{image1|[[Image:FMB630_autoCAN1.png|center|200px]]}}} |
| | | |
− | * SCAN scans once for available messages on CAN bus; | + | * SCAN - scans once for available messages on CAN bus; |
| * Monitoring – toggles scanning of messages on CAN bus every 3 seconds; | | * Monitoring – toggles scanning of messages on CAN bus every 3 seconds; |
| * Offline Configuration – enables CAN configuration when {{{model|FMB630}}} is not connected to CAN bus; | | * Offline Configuration – enables CAN configuration when {{{model|FMB630}}} is not connected to CAN bus; |
Line 16: |
Line 16: |
| * Value – shows scanned value of parameter; | | * Value – shows scanned value of parameter; |
| * Send data to server – allows to choose the type of data when it‘s generated: | | * Send data to server – allows to choose the type of data when it‘s generated: |
− | o Disabled – Data will not be collected
| + | * Disabled – Data will not be collected |
− | o On low priority – records will be generated as low priority events;
| + | * On low priority – records will be generated as low priority events; |
− | o On high priority – records will be generated as high priority events and immediately sent to server via GPRS (if GPRS is available);
| + | * On high priority – records will be generated as high priority events and immediately sent to server via GPRS (if GPRS is available); |
− | o On panic - records will be generated as panic priority events and immediately sent to server via GPRS, if GPRS is not available records will be sent via SMS messages;
| + | * On panic - records will be generated as panic priority events and immediately sent to server via GPRS, if GPRS is not available records will be sent via SMS messages; |
| * Data acquisition type – allows to choose when records are generated: | | * Data acquisition type – allows to choose when records are generated: |
− | oMonitoring – monitors data;
| + | *Monitoring – monitors data; |
− | oOn change – record is generated when parameter value is changed;
| + | *On change – record is generated when parameter value is changed; |
− | oHysteresis – record is generated when increasing parameter value becomes higher than High value, and decreasing becomes less than Low value
| + | *Hysteresis – record is generated when increasing parameter value becomes higher than High value, and decreasing becomes less than Low value |
− | oEvent on exit – record is generated when parameter value becomes higher than High value or lower than Low value;
| + | *Event on exit – record is generated when parameter value becomes higher than High value or lower than Low value; |
− | oEvent on entrance – record is generated when parameter value becomes between High and Low values;
| + | *Event on entrance – record is generated when parameter value becomes between High and Low values; |
− | oEvent on both – record is generated when parameter value crosses High or Low values;
| + | *Event on both – record is generated when parameter value crosses High or Low values; |
| * Low – allows to choose low value for Data acquisition; | | * Low – allows to choose low value for Data acquisition; |
| * High – allows to choose High level for Data acquisition; | | * High – allows to choose High level for Data acquisition; |