Changes

m
Text formatting
Line 16: Line 16:  
* Value – shows scanned value of parameter;
 
* Value – shows scanned value of parameter;
 
* Send data to server – allows to choose the type of data when it‘s generated:
 
* Send data to server – allows to choose the type of data when it‘s generated:
* Disabled – Data will not be collected
+
Disabled – Data will not be collected;<br>
* On low priority – records will be generated as low priority events;  
+
On low priority – records will be generated as low priority events; <br>
* On high priority – records will be generated as high priority events and immediately sent to server via GPRS (if GPRS is available);
+
On high priority – records will be generated as high priority events and immediately sent to server via GPRS (if GPRS is available);<br>
* On panic - records will be generated as panic priority events and immediately sent to server via GPRS, if GPRS is not available records will be sent via SMS messages;
+
On panic - records will be generated as panic priority events and immediately sent to server via GPRS, if GPRS is not available records will be sent via SMS messages;<br>
 
* Data acquisition type – allows to choose when records are generated:
 
* Data acquisition type – allows to choose when records are generated:
*Monitoring – monitors data;
+
Monitoring – monitors data;<br>
*On change – record is generated when parameter value is changed;
+
On change – record is generated when parameter value is changed;<br>
*Hysteresis – record is generated when increasing parameter value becomes higher than High value, and decreasing becomes less than Low value
+
Hysteresis – record is generated when increasing parameter value becomes higher than High value, and decreasing becomes less than Low value;<br>
*Event on exit – record is generated when parameter value becomes higher than High value or lower than Low value;
+
Event on exit – record is generated when parameter value becomes higher than High value or lower than Low value;<br>
*Event on entrance – record is generated when parameter value becomes between High and Low values;
+
Event on entrance – record is generated when parameter value becomes between High and Low values;<br>
*Event on both – record is generated when parameter value crosses High or Low values;
+
Event on both – record is generated when parameter value crosses High or Low values;<br>
 
* Low – allows to choose low value for Data acquisition;
 
* Low – allows to choose low value for Data acquisition;
 
* High – allows to choose High level for Data acquisition;
 
* High – allows to choose High level for Data acquisition;