| The second main parameter to configure is the movement source and ignition source. | | The second main parameter to configure is the movement source and ignition source. |
| | | |
− | Movement source parameter, which determines if the device should work in "Vehicle on Stop" or "Vehicle on Moving" mode. There are four possible movement sources: | + | Movement source parameter determines if the device should work in "Vehicle on Stop" or "Vehicle on Moving" mode. There are four possible movement sources: |
| | | |
| * Ignition - if Ignition (based on Ignition Source) is ON, Vehicle MOVING mode is used; if Ignition is OFF, Vehicle on STOP mode is used; | | * Ignition - if Ignition (based on Ignition Source) is ON, Vehicle MOVING mode is used; if Ignition is OFF, Vehicle on STOP mode is used; |
Line 93: |
Line 93: |
| * CAN Speed - if CAN adapter or FMS speed is >0 km/h, Vehicle MOVING mode is used; if CAN adapter or FMS speed is <=0 km/h, Vehicle on STOP mode is used; | | * CAN Speed - if CAN adapter or FMS speed is >0 km/h, Vehicle MOVING mode is used; if CAN adapter or FMS speed is <=0 km/h, Vehicle on STOP mode is used; |
| | | |
− | An ignition source will be used to determine the ignition of the vehicle. If voltage is between High Voltage Lever and Low Voltage Level (below Ignition Settings options) - ignition is ON. If voltage is higher than High Voltage Lever or lower than Low Voltage Level - ignition is OFF. | + | An ignition source will be used to determine the ignition of the vehicle. |
| | | |
− | * Digital Input 1 - if Digital Input 1 is 1 - ignition is ON; if Digital Input 1 value is 0 - ignition is OFF; | + | * Digital Input 1 - if Digital Input 1 value is 1 - ignition is ON; if Digital Input 1 value is 0 - ignition is OFF; |
− | * Digital Input 2 - if Digital Input 2 is 1 - ignition is ON; if Digital Input 2 value is 0 - ignition is OFF; | + | * Digital Input 2 - if Digital Input 2 value is 1 - ignition is ON; if Digital Input 2 value is 0 - ignition is OFF; |
− | * Digital Input 3 - if Digital Input 3 is 1 - ignition is ON; if Digital Input 3 value is 0 - ignition is OFF; | + | * Digital Input 3 - if Digital Input 3 value is 1 - ignition is ON; if Digital Input 3 value is 0 - ignition is OFF; |
− | * Digital Input 4 - if Digital Input 4 is 1 - ignition is ON; if Digital Input 4 value is 0 - ignition is OFF; | + | * Digital Input 4 - if Digital Input 4 value is 1 - ignition is ON; if Digital Input 4 value is 0 - ignition is OFF; |
| * Power Voltage - if the voltage is between High Voltage Lever and Low Voltage Level (below Ignition Settings options) - ignition is ON; if the voltage is higher than High Voltage Lever or lower than Low Voltage Level - ignition is OFF. | | * Power Voltage - if the voltage is between High Voltage Lever and Low Voltage Level (below Ignition Settings options) - ignition is ON; if the voltage is higher than High Voltage Lever or lower than Low Voltage Level - ignition is OFF. |
| * Movement - if Movement is still detected 1 after Movement Start Delay (s) - ignition is ON; if Movement value is 0 after Movement Stop Delay (s) - ignition is OFF; | | * Movement - if Movement is still detected 1 after Movement Start Delay (s) - ignition is ON; if Movement value is 0 after Movement Stop Delay (s) - ignition is OFF; |