Changes

Line 86: Line 86:  
The second main parameter to configure is the movement source and ignition source.
 
The second main parameter to configure is the movement source and ignition source.
   −
Movement source parameter, which determines if the device should work in "Vehicle on Stop" or "Vehicle on Moving" mode. There are four possible movement sources:
+
Movement source parameter determines if the device should work in "Vehicle on Stop" or "Vehicle on Moving" mode. There are four possible movement sources:
    
* Ignition - if Ignition (based on Ignition Source) is ON, Vehicle MOVING mode is used; if Ignition is OFF, Vehicle on STOP mode is used;
 
* Ignition - if Ignition (based on Ignition Source) is ON, Vehicle MOVING mode is used; if Ignition is OFF, Vehicle on STOP mode is used;
Line 93: Line 93:  
* CAN Speed - if CAN adapter or FMS speed is >0 km/h, Vehicle MOVING mode is used; if CAN adapter or FMS speed is <=0 km/h, Vehicle on STOP mode is used;
 
* CAN Speed - if CAN adapter or FMS speed is >0 km/h, Vehicle MOVING mode is used; if CAN adapter or FMS speed is <=0 km/h, Vehicle on STOP mode is used;
   −
An ignition source will be used to determine the ignition of the vehicle. If voltage is between High Voltage Lever and Low Voltage Level (below Ignition Settings options) - ignition is ON. If voltage is higher than High Voltage Lever or lower than Low Voltage Level - ignition is OFF.
+
An ignition source will be used to determine the ignition of the vehicle.  
   −
* Digital Input 1 - if Digital Input 1 is 1 - ignition is ON; if Digital Input 1 value is 0 - ignition is OFF;
+
* Digital Input 1 - if Digital Input 1 value  is 1 - ignition is ON; if Digital Input 1 value is 0 - ignition is OFF;
* Digital Input 2 - if Digital Input 2 is 1 - ignition is ON; if Digital Input 2 value is 0 - ignition is OFF;
+
* Digital Input 2 - if Digital Input 2 value  is 1 - ignition is ON; if Digital Input 2 value is 0 - ignition is OFF;
* Digital Input 3 - if Digital Input 3 is 1 - ignition is ON; if Digital Input 3 value is 0 - ignition is OFF;
+
* Digital Input 3 - if Digital Input 3 value  is 1 - ignition is ON; if Digital Input 3 value is 0 - ignition is OFF;
* Digital Input 4 - if Digital Input 4 is 1 - ignition is ON; if Digital Input 4 value is 0 - ignition is OFF;
+
* Digital Input 4 - if Digital Input 4 value  is 1 - ignition is ON; if Digital Input 4 value is 0 - ignition is OFF;
 
* Power Voltage - if the voltage is between High Voltage Lever and Low Voltage Level (below Ignition Settings options) - ignition is ON; if the voltage is higher than High Voltage Lever or lower than Low Voltage Level - ignition is OFF.
 
* Power Voltage - if the voltage is between High Voltage Lever and Low Voltage Level (below Ignition Settings options) - ignition is ON; if the voltage is higher than High Voltage Lever or lower than Low Voltage Level - ignition is OFF.
 
* Movement - if Movement is still detected 1 after Movement Start Delay (s) - ignition is ON; if Movement value is 0 after Movement Stop Delay (s) - ignition is OFF;
 
* Movement - if Movement is still detected 1 after Movement Start Delay (s) - ignition is ON; if Movement value is 0 after Movement Stop Delay (s) - ignition is OFF;