FMB120 Product Change Notifications: Difference between revisions
FMB120 Product Change Notifications (view source)
Revision as of 12:31, 11 October 2022
, 11 October 2022no edit summary
No edit summary |
|||
Line 2: | Line 2: | ||
| product_name = FMB120 tracking device | | product_name = FMB120 tracking device | ||
}} | }} | ||
==2022.11.01: Base firmware update== | |||
We would like to inform you about the base firmware update for FMB120 starting from November 1st, 2022. New production firmware version will be 03.27.13.Rev.03 | |||
{| class="wikitable" | |||
|+ | |||
! colspan="3" style="text-align: left; background: white;" |Change description | |||
|- | |||
| style="text-align: left; background: white;" |Change type | |||
| colspan="2" style="text-align: left; background: white;" |Firmware update | |||
|- | |||
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description | |||
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB120_firmware_errata | |||
|- | |||
| style="text-align: left; background: white;" |Old version: <br> FMB120 03.27.13.Rev.03 | |||
| style="text-align: left; background: white;" |New version: <br> FMB120 03.27.14.Rev.00 | |||
|- | |||
| style="text-align: left; background: white;" |Change reasons | |||
| colspan="2" style="text-align: left; background: white;" |PCB design optimization due to prevent the shortage of 1-wire components and ensure stable supply. | |||
Together with PCB design update new firmware released to support changes in updated hardware. | |||
|- | |||
| style="text-align: left; background: white;" | Product release date | |||
| colspan="2" style="text-align: left; background: white;" |2022-November – Firmware Update <br>2023-January – PCB design Changes</br> | |||
|- | |||
|} | |||
{| class="wikitable" | |||
|+ | |||
! colspan="3" style="text-align: left; background: white;" |Affected products | |||
|- | |||
| style="width: 221px; text-align: left; background: white;" |Model | |||
| style="width: 448px; text-align: left; background: white;" |Affected order codes | |||
| style="width: 448px; text-align: left; background: white;" | Order code changes | |||
|- | |||
| style="text-align: left; background: white;" |FMB120 | |||
| style="text-align: left; background: white;" |FMB120 order codes | |||
| style="text-align: left; background: white;" |Update firmware <br>Update PCB design</br> | |||
|- | |||
|} | |||
{| class="wikitable" | |||
|+ | |||
! colspan="3" style="text-align: left; background: white;" |Change impact | |||
|- | |||
| style="width: 221px; text-align: left; background: white;" |Risk assessment | |||
| colspan="2" style="width: 908px; text-align: left; background: white;" |1. Clients with special firmware versions or order codes with special firmware will have to update firmware manually. | |||
2. Using old firmware version on updated PCB will cause of 1-wire malfunction. | |||
|- | |||
| style="text-align: left; background: white;" |Suggested implementation plan | |||
| colspan="2" style="text-align: left; background: white;" | 1. We highly recommend updating the spec.firmware`s with the latest version in order to support new changes on FMB120 hardware. | |||
2. For further assistance, including the updates of special firmware versions, please contact your Teltonika Telematics sales manager or fill query on VIP HelpDesk. | |||
|- | |||
|} | |||
==2022.08.01: Base firmware update== | ==2022.08.01: Base firmware update== |