Line 2: |
Line 2: |
| | | |
| | | |
− | ==='''Step 1.''' First you have to connect the FMx640 with the RS232. On COM1 The below picture illustrates the connection:=== | + | ==='''Step 1.''' Connect the FMx640 with the RS232 on COM1 The below picture illustrates the connection:=== |
| | | |
− | [[File:FMC640 RS232 fuad.jpg|center|thumb|500x500px|A Picture to Illustrate the Physical Connection from device side.]] | + | [[File:FMX640 and RS232 illustration v1.2.png|alt=|center|thumb|800x800px|A Picture to Illustrate the Physical Connection from device side.]] |
| | | |
| | | |
− | ==='''Step 2.''' Second step after the connections, you must configure the FMx640:=== | + | ==='''Step 2.''' FMx640 Configuration:=== |
| | | |
| The FMx configurator you have to set parameters for COM1 or COM2 (depends on which COM port you are using) in global parameters window. You have to modify the server sittings to you PC IP and your TCP port. | | The FMx configurator you have to set parameters for COM1 or COM2 (depends on which COM port you are using) in global parameters window. You have to modify the server sittings to you PC IP and your TCP port. |
Line 20: |
Line 20: |
| | | |
| | | |
− | '''Note:''' Try to make sure that your TCP Port is open by checking the below website: | + | '''Note:''' Try to make sure that your TCP Port is open by checking the below websites. |
| | | |
− | Port Checker - [https://portchecker.co/ Check Open Ports Online]
| |
| | | |
− | | + | ==='''Step 3.''' Establishing FMx test link with server through Hercules and sending messages with Hercule:=== |
− | ==='''Step 3.''' Establishing FMx test link with server through Hercules and sending messages with Hercule:=== | |
| | | |
| | | |
Line 38: |
Line 36: |
| | | |
| | | |
− | ==='''Step 4.''' Receiving messages with Hercules:=== | + | ==='''Step 4.''' Receiving messages with Hercules:=== |
| | | |
| In this step we need to use the terminal log. When you want to send a message from FMx 640 to the server, write it in Terminal but change your com port and select port which is assigned for COM1/COM2. | | In this step we need to use the terminal log. When you want to send a message from FMx 640 to the server, write it in Terminal but change your com port and select port which is assigned for COM1/COM2. |
Line 51: |
Line 49: |
| | | |
| | | |
− | ==='''The Conclusion of this test:'''=== | + | ==='''The Conclusion:'''=== |
| | | |
| In this mode link with an external device for example PC using text messages can be established. We can apply this scenario on FMx640 or FMx125 which have to be connected to the external device through RS232 or RS485. Any string of data coming to device via RS232 or RS485 will be routed to the server ''(if the link is currently active)''. Messages that are exchanged between FMx device and server, have to be packed in Codec.12 format and will receive to the Hercules receiver successfully. | | In this mode link with an external device for example PC using text messages can be established. We can apply this scenario on FMx640 or FMx125 which have to be connected to the external device through RS232 or RS485. Any string of data coming to device via RS232 or RS485 will be routed to the server ''(if the link is currently active)''. Messages that are exchanged between FMx device and server, have to be packed in Codec.12 format and will receive to the Hercules receiver successfully. |